Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />Job <br />25-0691-001 <br />Truss <br />C01 <br />Truss Type <br />MONOPITCH GIRDER <br />Qty <br />1 <br />Ply <br />2 <br />Raising Cane's #C1032 <br />Job Reference (optional) <br />R89895419 <br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:28 2025 Page 1 Precision Truss, Citrus Heights, CA <br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-xiA80zFgUDpic_jYMbc1UVh2IkMUuZ1J_XpOyZyjuGD <br />Scale = 1:43.4 <br />1 2 3 4 5 6 7 8 <br />16 15 14 13 12 11 10 <br />9 <br />18 <br />17 <br />19 <br />20 21 22 23 24 25 26 27 28 <br />29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 <br />443x5 <br />3x4 <br />4x6 8x8 4x10 <br />8x10 <br />3x8 <br />3x4 <br />3x4 <br />3x4 3x8 <br />4x10 <br />5x12 <br />3x6 <br />2x4 <br />MUS26 LUS24 LUS24 <br />LUS24 <br />LUS24 <br />LUS24 <br />LUS24 <br />LUS24 LUS24 <br />LUS24 <br />LUS24 <br />LUS24 <br />2-0-0 <br />2-0-0 <br />5-2-1 <br />3-2-1 <br />10-0-9 <br />4-10-8 <br />14-11-1 <br />4-10-8 <br />19-9-9 <br />4-10-8 <br />24-11-10 <br />5-2-1 <br />0-5-10 <br />0-5-10 <br />2-0-0 <br />1-6-6 <br />5-2-1 <br />3-2-1 <br />10-0-9 <br />4-10-8 <br />14-11-1 <br />4-10-8 <br />19-9-9 <br />4-10-8 <br />24-11-10 <br />5-2-1 <br />1- <br />3 <br />- <br />1 <br />0 <br />7- <br />0 <br />- <br />8 <br />2- <br />4 <br />- <br />2 <br />2- <br />9 <br />- <br />1 <br />2 <br />1- <br />0 <br />- <br />0 <br />0.25 12 <br />Plate Offsets (X,Y)-- [3:0-3-0,0-4-8], [11:0-4-0,0-4-8], [13:0-3-9,0-1-8], [14:0-3-9,0-2-0], [17:0-4-0,0-2-4] <br />LOADING (psf) <br />TCLL <br />TCDL <br />BCLL <br />BCDL <br />20.0 <br />15.0 <br />0.0 * <br />10.0 <br />SPACING- <br />Plate Grip DOL <br />Lumber DOL <br />Rep Stress Incr <br />Code <br />2-0-0 <br />1.25 <br />1.25 <br />NO <br />IBC2021/TPI2014 <br />CSI. <br />TC <br />BC <br />WB <br />Matrix-MS <br />0.49 <br />0.78 <br />0.87 <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in <br />-0.21 <br />-0.60 <br />0.07 <br />0.09 <br />(loc) <br />12-13 <br />12-13 <br />10 <br />12-13 <br />l/defl <br />>999 <br />>491 <br />n/a <br />>999 <br />L/d <br />360 <br />240 <br />n/a <br />240 <br />PLATES <br />MT20 <br />Weight: 345 lb FT = 20% <br />GRIP <br />220/195 <br />LUMBER- <br />TOP CHORD 2x6 DF No.2 G <br />BOT CHORD 2x6 DF No.2 G *Except* <br />17-18: 2x4 DF No.1&Btr G <br />WEBS 2x4 DF Std G *Except* <br />14-17: 2x4 DF No.1&Btr G <br />OTHERS 2x6 DF No.2 G <br />BRACING- <br />TOP CHORD Structural wood sheathing directly applied or 5-1-12 oc purlins, <br />except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />REACTIONS.(lb/size)18=1664/0-5-8, 10=1648/0-2-11 <br />Max Horz 18=214(LC 66) <br />Max Uplift 18=-358(LC 8), 10=-127(LC 12) <br />Max Grav 18=3293(LC 29), 10=3448(LC 36) <br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 1-18=-3207/694, 1-20=-5253/1718, 2-20=-5252/1718, 2-21=-4958/1622, 3-21=-4950/1622, <br /> 3-22=-9999/1195, 22-23=-9996/1196, 23-24=-9996/1196, 4-24=-9995/1198, <br />4-25=-9456/1138, 25-26=-9454/1140, 5-26=-9453/1142, 5-27=-6207/773, 6-27=-6206/774, <br /> 7-10=-478/80 <br />BOT CHORD 15-30=-160/430, 30-31=-160/430, 14-31=-160/430, 14-32=-1232/7165, 32-33=-1232/7165, <br /> 33-34=-1232/7165, 13-34=-1232/7165, 13-35=-1255/9993, 35-36=-1255/9993, <br />36-37=-1255/9993, 12-37=-1255/9993, 12-38=-1194/9451, 38-39=-1194/9451, <br />39-40=-1194/9451, 11-40=-1194/9451, 11-41=-810/6030, 41-42=-810/6030, <br />42-43=-810/6030, 10-43=-810/6030, 18-44=-900/1424, 17-44=-900/1424 <br />WEBS 14-17=-1112/7088, 3-14=-994/284, 3-13=-305/3224, 4-13=-336/191, 4-12=-901/65, <br />5-12=-49/1412, 5-11=-3715/408, 6-11=-192/2708, 6-10=-6445/842, 15-17=-399/1103, <br />2-17=-120/559, 3-17=-2549/630, 1-17=-1013/5463 <br />NOTES-(16) <br />1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: <br />Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. <br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. <br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to <br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. <br />3) Unbalanced roof live loads have been considered for this design. <br />4) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; <br />MWFRS (envelope) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members <br />and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 <br />5) Provide adequate drainage to prevent water ponding. <br />6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />Continued on page 2 <br />VERTICAL SUPPORT OF FREE END <br />OF CHORD IS REQUIRED. <br />August 27,2025