Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />Job <br />25-0691-001 <br />Truss <br />C09 <br />Truss Type <br />MONOPITCH <br />Qty <br />1 <br />Ply <br />2 <br />Raising Cane's #C1032 <br />Job Reference (optional) <br />R89895427 <br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:36 2025 Page 1 Precision Truss, Citrus Heights, CA <br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-iFf9hiLicgpZZDK5qHmvpB0RSy5rmC_UpnlpE5yjuG5 <br />Scale = 1:43.6 <br />1 2 3 4 5 6 <br />12 11 10 9 8 7 <br />13 <br />14 15 16 17 18 19 20 <br />21 22 23 24 25 26 27 <br />4x4 <br />4x10 M18AHS <br />5x12 M18AHS8x8 3x12 <br />5x10 <br />8x8 <br />3x10 <br />3x4 4x10 <br />HHUS26-2 <br />HHUS26-2 <br />6-4-11 <br />6-4-11 <br />12-5-13 <br />6-1-2 <br />18-6-15 <br />6-1-2 <br />24-11-10 <br />6-4-11 <br />6-4-11 <br />6-4-11 <br />12-5-13 <br />6-1-2 <br />18-6-15 <br />6-1-2 <br />24-11-10 <br />6-4-11 <br />2- <br />3 <br />- <br />1 <br />0 <br />7- <br />0 <br />- <br />8 <br />2- <br />4 <br />- <br />2 <br />2- <br />9 <br />- <br />1 <br />2 <br />0.25 12 <br />Plate Offsets (X,Y)-- [2:0-4-0,0-4-8], [9:0-4-0,0-5-0], [10:0-3-9,0-1-8], [11:0-3-9,0-1-8] <br />LOADING (psf) <br />TCLL <br />TCDL <br />BCLL <br />BCDL <br />20.0 <br />15.0 <br />0.0 * <br />10.0 <br />SPACING- <br />Plate Grip DOL <br />Lumber DOL <br />Rep Stress Incr <br />Code <br />2-0-0 <br />1.25 <br />1.25 <br />NO <br />IBC2021/TPI2014 <br />CSI. <br />TC <br />BC <br />WB <br />Matrix-MS <br />0.42 <br />0.82 <br />0.74 <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in <br />-0.11 <br />-0.84 <br />0.11 <br />0.05 <br />(loc) <br />9-10 <br />9-10 <br />8 <br />10 <br />l/defl <br />>999 <br />>349 <br />n/a <br />>999 <br />L/d <br />360 <br />240 <br />n/a <br />240 <br />PLATES <br />MT20 <br />M18AHS <br />Weight: 329 lb FT = 20% <br />GRIP <br />220/195 <br />169/162 <br />LUMBER- <br />TOP CHORD 2x6 DF SS G <br />BOT CHORD 2x6 DF SS G <br />WEBS 2x4 DF Std G *Except* <br />12-13: 2x6 DF No.2 G, 5-8,1-11: 2x4 DF No.1&Btr G <br />BRACING- <br />TOP CHORD Structural wood sheathing directly applied or 5-8-2 oc purlins, <br />except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />WEBS 1 Row at midpt 4-8 <br />REACTIONS.(lb/size)12=2519/0-5-8, 8=3925/0-2-11 <br />Max Horz 12=220(LC 9) <br />Max Grav 12=2535(LC 29), 8=4486(LC 34) <br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 1-12=-2151/0, 1-14=-6280/0, 2-14=-6276/0, 2-15=-10076/0, 15-16=-10074/0, <br />16-17=-10073/0, 3-17=-10072/0, 3-18=-8980/0, 4-18=-8966/0, 4-19=-460/0, <br />19-20=-444/0, 5-20=-432/0, 5-8=-979/0 <br />BOT CHORD 12-21=-474/1145, 21-22=-474/1145, 22-23=-474/1145, 11-23=-474/1145, 11-24=0/6399, <br />10-24=0/6399, 10-25=0/10071, 9-25=0/10071, 9-26=0/8855, 26-27=0/8855, 8-27=0/8855 <br />WEBS 1-11=0/6188, 2-11=-1622/0, 2-10=0/4107, 3-10=-380/0, 3-9=-1383/219, 4-9=0/1806, <br />4-8=-8978/0 <br />NOTES-(16) <br />1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: <br />Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. <br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. <br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to <br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. <br />3) Unbalanced roof live loads have been considered for this design. <br />4) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; <br />MWFRS (envelope) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members <br />and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 <br />5) Provide adequate drainage to prevent water ponding. <br />6) All plates are MT20 plates unless otherwise indicated. <br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />9) A plate rating reduction of 20% has been applied for the green lumber members. <br />10) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8. <br />11) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all <br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads. <br />12) Use Simpson Strong-Tie HHUS26-2 (14-10d Girder, 4-10d Truss) or equivalent spaced at 7-5-10 oc max. starting at 15-4-8 from <br />the left end to 22-10-2 to connect truss(es) to front face of bottom chord. <br />13) Fill all nail holes where hanger is in contact with lumber. <br />Continued on page 2 <br />August 27,2025