400 Sunrise Ave., Suite 270
<br />Roseville, CA 95661
<br />916.755.3571 / MiTek-US.com
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />BCSI Building Component Safety Information
<br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />and available from the Structural Building Component Association (www.sbcscomponents.com)
<br />Job
<br />25-0691-001
<br />Truss
<br />C09
<br />Truss Type
<br />MONOPITCH
<br />Qty
<br />1
<br />Ply
<br />2
<br />Raising Cane's #C1032
<br />Job Reference (optional)
<br />R89895427
<br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:36 2025 Page 1 Precision Truss, Citrus Heights, CA
<br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-iFf9hiLicgpZZDK5qHmvpB0RSy5rmC_UpnlpE5yjuG5
<br />Scale = 1:43.6
<br />1 2 3 4 5 6
<br />12 11 10 9 8 7
<br />13
<br />14 15 16 17 18 19 20
<br />21 22 23 24 25 26 27
<br />4x4
<br />4x10 M18AHS
<br />5x12 M18AHS8x8 3x12
<br />5x10
<br />8x8
<br />3x10
<br />3x4 4x10
<br />HHUS26-2
<br />HHUS26-2
<br />6-4-11
<br />6-4-11
<br />12-5-13
<br />6-1-2
<br />18-6-15
<br />6-1-2
<br />24-11-10
<br />6-4-11
<br />6-4-11
<br />6-4-11
<br />12-5-13
<br />6-1-2
<br />18-6-15
<br />6-1-2
<br />24-11-10
<br />6-4-11
<br />2-
<br />3
<br />-
<br />1
<br />0
<br />7-
<br />0
<br />-
<br />8
<br />2-
<br />4
<br />-
<br />2
<br />2-
<br />9
<br />-
<br />1
<br />2
<br />0.25 12
<br />Plate Offsets (X,Y)-- [2:0-4-0,0-4-8], [9:0-4-0,0-5-0], [10:0-3-9,0-1-8], [11:0-3-9,0-1-8]
<br />LOADING (psf)
<br />TCLL
<br />TCDL
<br />BCLL
<br />BCDL
<br />20.0
<br />15.0
<br />0.0 *
<br />10.0
<br />SPACING-
<br />Plate Grip DOL
<br />Lumber DOL
<br />Rep Stress Incr
<br />Code
<br />2-0-0
<br />1.25
<br />1.25
<br />NO
<br />IBC2021/TPI2014
<br />CSI.
<br />TC
<br />BC
<br />WB
<br />Matrix-MS
<br />0.42
<br />0.82
<br />0.74
<br />DEFL.
<br />Vert(LL)
<br />Vert(CT)
<br />Horz(CT)
<br />Wind(LL)
<br />in
<br />-0.11
<br />-0.84
<br />0.11
<br />0.05
<br />(loc)
<br />9-10
<br />9-10
<br />8
<br />10
<br />l/defl
<br />>999
<br />>349
<br />n/a
<br />>999
<br />L/d
<br />360
<br />240
<br />n/a
<br />240
<br />PLATES
<br />MT20
<br />M18AHS
<br />Weight: 329 lb FT = 20%
<br />GRIP
<br />220/195
<br />169/162
<br />LUMBER-
<br />TOP CHORD 2x6 DF SS G
<br />BOT CHORD 2x6 DF SS G
<br />WEBS 2x4 DF Std G *Except*
<br />12-13: 2x6 DF No.2 G, 5-8,1-11: 2x4 DF No.1&Btr G
<br />BRACING-
<br />TOP CHORD Structural wood sheathing directly applied or 5-8-2 oc purlins,
<br />except end verticals.
<br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
<br />WEBS 1 Row at midpt 4-8
<br />REACTIONS.(lb/size)12=2519/0-5-8, 8=3925/0-2-11
<br />Max Horz 12=220(LC 9)
<br />Max Grav 12=2535(LC 29), 8=4486(LC 34)
<br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 1-12=-2151/0, 1-14=-6280/0, 2-14=-6276/0, 2-15=-10076/0, 15-16=-10074/0,
<br />16-17=-10073/0, 3-17=-10072/0, 3-18=-8980/0, 4-18=-8966/0, 4-19=-460/0,
<br />19-20=-444/0, 5-20=-432/0, 5-8=-979/0
<br />BOT CHORD 12-21=-474/1145, 21-22=-474/1145, 22-23=-474/1145, 11-23=-474/1145, 11-24=0/6399,
<br />10-24=0/6399, 10-25=0/10071, 9-25=0/10071, 9-26=0/8855, 26-27=0/8855, 8-27=0/8855
<br />WEBS 1-11=0/6188, 2-11=-1622/0, 2-10=0/4107, 3-10=-380/0, 3-9=-1383/219, 4-9=0/1806,
<br />4-8=-8978/0
<br />NOTES-(16)
<br />1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
<br />Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
<br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
<br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
<br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
<br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
<br />3) Unbalanced roof live loads have been considered for this design.
<br />4) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed;
<br />MWFRS (envelope) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
<br />and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
<br />5) Provide adequate drainage to prevent water ponding.
<br />6) All plates are MT20 plates unless otherwise indicated.
<br />7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />will fit between the bottom chord and any other members.
<br />9) A plate rating reduction of 20% has been applied for the green lumber members.
<br />10) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 8.
<br />11) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all
<br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads.
<br />12) Use Simpson Strong-Tie HHUS26-2 (14-10d Girder, 4-10d Truss) or equivalent spaced at 7-5-10 oc max. starting at 15-4-8 from
<br />the left end to 22-10-2 to connect truss(es) to front face of bottom chord.
<br />13) Fill all nail holes where hanger is in contact with lumber.
<br />Continued on page 2
<br />August 27,2025
|