Laserfiche WebLink
400 Sunrise Ave., Suite 270 <br />Roseville, CA 95661 <br />916.755.3571 / MiTek-US.com <br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not <br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall <br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing <br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the <br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org) <br />BCSI Building Component Safety Information <br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE. <br />and available from the Structural Building Component Association (www.sbcscomponents.com) <br />Job <br />25-0691-001 <br />Truss <br />C15 <br />Truss Type <br />MONOPITCH <br />Qty <br />1 <br />Ply <br />2 <br />Raising Cane's #C1032 <br />Job Reference (optional) <br />R89895433 <br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:42 2025 Page 1 Precision Truss, Citrus Heights, CA <br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-XP0RylPTBWajH8nFBXtJ2SGStNBvAu6NCiC7RlyjuG? <br />Scale = 1:41.8 <br />1 2 3 4 5 6 7 8 <br />16 15 14 13 12 11 10 <br />9 <br />17 <br />18 19 20 21 22 23 24 25 <br />26 27 28 29 30 31 32 33 34 <br />3x4 <br />8x8 3x8 <br />4x6 8x8 4x10 <br />6x10 <br />3x4 <br />3x4 3x5 <br />2x4 4x6 <br />3x10 <br />3x4 <br />2-3-03-10-01- <br />9 <br />- <br />0 <br />4-11-2 <br />4-11-2 <br />9-6-6 <br />4-7-4 <br />14-1-10 <br />4-7-4 <br />18-8-14 <br />4-7-4 <br />22-10-7 <br />4-1-9 <br />24-11-10 <br />2-1-4 <br />4-11-2 <br />4-11-2 <br />9-6-6 <br />4-7-4 <br />14-1-10 <br />4-7-4 <br />18-8-14 <br />4-7-4 <br />22-10-7 <br />4-1-9 <br />24-11-10 <br />2-1-4 <br />2- <br />3 <br />- <br />1 <br />0 <br />7- <br />0 <br />- <br />8 <br />2- <br />4 <br />- <br />2 <br />2- <br />9 <br />- <br />1 <br />2 <br />0.25 12 <br />Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [14:0-4-0,0-4-8], [15:0-3-9,0-2-0] <br />LOADING (psf) <br />TCLL <br />TCDL <br />BCLL <br />BCDL <br />20.0 <br />15.0 <br />0.0 * <br />10.0 <br />SPACING- <br />Plate Grip DOL <br />Lumber DOL <br />Rep Stress Incr <br />Code <br />2-0-0 <br />1.25 <br />1.25 <br />YES <br />IBC2021/TPI2014 <br />CSI. <br />TC <br />BC <br />WB <br />Matrix-MS <br />0.42 <br />0.58 <br />0.89 <br />DEFL. <br />Vert(LL) <br />Vert(CT) <br />Horz(CT) <br />Wind(LL) <br />in <br />-0.09 <br />-0.66 <br />0.06 <br />0.08 <br />(loc) <br />12-13 <br />12-13 <br />10 <br />12-13 <br />l/defl <br />>999 <br />>446 <br />n/a <br />>999 <br />L/d <br />360 <br />240 <br />n/a <br />240 <br />PLATES <br />MT20 <br />Weight: 329 lb FT = 20% <br />GRIP <br />220/195 <br />LUMBER- <br />TOP CHORD 2x6 DF SS G <br />BOT CHORD 2x6 DF SS G <br />WEBS 2x4 DF Std G *Except* <br />16-17: 2x6 DF No.2 G <br />BRACING- <br />TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, <br />except end verticals. <br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. <br />REACTIONS.(lb/size)16=2244/0-5-8, 10=1933/0-2-11 <br />Max Horz 16=220(LC 9) <br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. <br />TOP CHORD 1-16=-2123/0, 1-18=-4150/0, 18-19=-4139/0, 2-19=-4139/0, 2-20=-5496/0, <br />3-20=-5493/0, 3-21=-5934/0, 4-21=-5929/0, 4-22=-3021/0, 22-23=-3016/0, <br />5-23=-3012/0, 5-24=-2999/0, 6-24=-2989/0, 7-10=0/911 <br />BOT CHORD 16-26=-470/1083, 15-26=-470/1083, 15-27=0/4138, 27-28=0/4138, 14-28=0/4138, <br />14-29=0/5524, 29-30=0/5524, 13-30=0/5524, 13-31=0/5889, 31-32=0/5889, 12-32=0/5889, <br /> 12-33=0/3008, 11-33=0/3008, 11-34=0/3008, 10-34=0/3008 <br />WEBS 1-15=0/4127, 2-15=-927/66, 2-14=0/1500, 4-13=0/793, 4-12=-3191/0, 5-12=0/686, <br />6-10=-4794/0, 6-11=0/1697, 3-14=-441/158, 3-13=0/751 <br />NOTES-(13) <br />1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows: <br />Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc. <br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc. <br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc. <br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to <br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated. <br />3) Unbalanced roof live loads have been considered for this design. <br />4) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed; <br />MWFRS (envelope) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members <br />and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33 <br />5) Provide adequate drainage to prevent water ponding. <br />6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. <br />7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide <br />will fit between the bottom chord and any other members. <br />8) A plate rating reduction of 20% has been applied for the green lumber members. <br />9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10. <br />10) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all <br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads. <br />11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 177 lb down at 0-11-14, 177 lb <br />down at 0-11-14, 19 lb down at 22-8-0, 19 lb down at 22-8-0, and 19 lb down at 15-9-8, and 19 lb down at 15-9-8 on top chord. <br />The design/selection of such connection device(s) is the responsibility of others. <br />12) This truss is designed for a creep factor of 3.01, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1. <br />Continued on page 2 <br />August 27,2025