400 Sunrise Ave., Suite 270
<br />Roseville, CA 95661
<br />916.755.3571 / MiTek-US.com
<br />Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
<br />a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
<br />building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
<br />is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
<br />fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria and DSB-22 available from Truss Plate Institute (www.tpinst.org)
<br />BCSI Building Component Safety Information
<br />WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 1/2/2023 BEFORE USE.
<br />and available from the Structural Building Component Association (www.sbcscomponents.com)
<br />Job
<br />25-0691-001
<br />Truss
<br />C16
<br />Truss Type
<br />MONOPITCH
<br />Qty
<br />1
<br />Ply
<br />2
<br />Raising Cane's #C1032
<br />Job Reference (optional)
<br />R89895434
<br />Run: 8.810 s Mar 20 2025 Print: 8.830 s Aug 14 2025 MiTek Industries, Inc. Tue Aug 26 16:55:44 2025 Page 1 Precision Truss, Citrus Heights, CA
<br />ID:tU1woLeiXBgGwrpxhgDG1JywmId-Tn8BNRRjj8qQXRxdIyvn7tLnjAsiepMgf0hEVeyjuFz
<br />Scale = 1:41.8
<br />1 2 3 4 5 6 7 8
<br />16 15 14 13 12 11 10
<br />9
<br />17
<br />18 19 20 21 22 23 24
<br />25 26 27 28 29 30 31
<br />3x4
<br />8x8 3x8
<br />4x6 8x8 3x10
<br />4x8
<br />3x6
<br />3x4 3x5
<br />2x4 4x6
<br />3x10
<br />3x4
<br />2-3-03-10-01-
<br />9
<br />-
<br />0
<br />4-11-2
<br />4-11-2
<br />9-6-6
<br />4-7-4
<br />14-1-10
<br />4-7-4
<br />18-8-14
<br />4-7-4
<br />22-10-7
<br />4-1-9
<br />24-11-10
<br />2-1-4
<br />4-11-2
<br />4-11-2
<br />9-6-6
<br />4-7-4
<br />14-1-10
<br />4-7-4
<br />18-8-14
<br />4-7-4
<br />22-10-7
<br />4-1-9
<br />24-11-10
<br />2-1-4
<br />2-
<br />3
<br />-
<br />1
<br />0
<br />7-
<br />0
<br />-
<br />8
<br />2-
<br />4
<br />-
<br />2
<br />2-
<br />9
<br />-
<br />1
<br />2
<br />0.25 12
<br />Plate Offsets (X,Y)-- [4:0-4-0,0-4-8], [14:0-4-0,0-4-8], [15:0-3-9,0-1-8]
<br />LOADING (psf)
<br />TCLL
<br />TCDL
<br />BCLL
<br />BCDL
<br />20.0
<br />15.0
<br />0.0 *
<br />10.0
<br />SPACING-
<br />Plate Grip DOL
<br />Lumber DOL
<br />Rep Stress Incr
<br />Code
<br />2-0-0
<br />1.25
<br />1.25
<br />YES
<br />IBC2021/TPI2014
<br />CSI.
<br />TC
<br />BC
<br />WB
<br />Matrix-MS
<br />0.46
<br />0.63
<br />0.78
<br />DEFL.
<br />Vert(LL)
<br />Vert(CT)
<br />Horz(CT)
<br />Wind(LL)
<br />in
<br />-0.09
<br />-0.70
<br />0.06
<br />0.08
<br />(loc)
<br />12-13
<br />12-13
<br />10
<br />12-13
<br />l/defl
<br />>999
<br />>418
<br />n/a
<br />>999
<br />L/d
<br />360
<br />240
<br />n/a
<br />240
<br />PLATES
<br />MT20
<br />Weight: 329 lb FT = 20%
<br />GRIP
<br />220/195
<br />LUMBER-
<br />TOP CHORD 2x6 DF SS G
<br />BOT CHORD 2x6 DF SS G
<br />WEBS 2x4 DF Std G *Except*
<br />16-17: 2x6 DF No.2 G
<br />BRACING-
<br />TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins,
<br />except end verticals.
<br />BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
<br />REACTIONS.(lb/size)16=1723/0-5-8, 10=2188/0-2-11
<br />Max Horz 16=220(LC 9)
<br />FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
<br />TOP CHORD 1-16=-1619/0, 1-18=-3678/0, 2-18=-3674/0, 2-19=-5570/0, 3-19=-5562/0, 3-20=-6133/0,
<br /> 4-20=-6128/0, 4-21=-3335/0, 21-22=-3326/0, 5-22=-3320/0, 5-23=-3309/0,
<br />6-23=-3297/0, 7-10=0/982
<br />BOT CHORD 16-25=-559/993, 15-25=-559/993, 15-26=0/3673, 14-26=0/3673, 14-27=0/5623,
<br />13-27=0/5623, 13-28=0/6105, 28-29=0/6105, 12-29=0/6105, 12-30=0/3318, 11-30=0/3318,
<br /> 11-31=0/3318, 10-31=0/3318
<br />WEBS 1-15=0/3725, 2-15=-1300/0, 2-14=0/2091, 4-13=0/560, 4-12=-3086/0, 5-12=0/588,
<br />6-10=-5284/0, 6-11=0/1798, 3-14=-839/0, 3-13=0/860
<br />NOTES-(13)
<br />1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
<br />Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.
<br />Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.
<br />Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
<br />2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
<br />ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
<br />3) Unbalanced roof live loads have been considered for this design.
<br />4) Wind: ASCE 7-16; Vult=95mph (3-second gust) Vasd=75mph; TCDL=6.0psf; BCDL=6.0psf; h=25ft; Cat. II; Exp C; Enclosed;
<br />MWFRS (envelope) and C-C Corner(3) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members
<br />and forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
<br />5) Provide adequate drainage to prevent water ponding.
<br />6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
<br />7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
<br />will fit between the bottom chord and any other members.
<br />8) A plate rating reduction of 20% has been applied for the green lumber members.
<br />9) Provide mechanical connection (by others) of truss to bearing plate at joint(s) 10.
<br />10) This truss has been designed for a moving concentrated load of 250.0lb live and 100.0lb dead located at all mid panels and at all
<br />panel points along the Top Chord and Bottom Chord, nonconcurrent with any other live loads.
<br />11) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 123 lb down at 9-6-10, 123 lb
<br />down at 9-6-10, 123 lb down at 7-2-9, 123 lb down at 7-2-9, 73 lb down at 22-9-10, 73 lb down at 22-9-10, and 73 lb down at
<br />15-2-8, and 73 lb down at 15-2-8 on top chord. The design/selection of such connection device(s) is the responsibility of others.
<br />12) This truss is designed for a creep factor of 3.01, which is used to calculate the Vert(CT) deflection per ANSI/TPI 1.
<br />Continued on page 2
<br />August 27,2025
|