Laserfiche WebLink
NOTES FOR STANDARD STRINC SYSTEM ELECTRICAL DIACRAM <br />Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systemsv'vrl SoLr Develop., LLC <br />Sa.la lo sp.r.g6. CA 90670 <br />s2-9a2.12tO <br />Sile Name R^-r!!q <br />Site Address: .'.,'*,,, <br />System AC Size: ,"-" <br />NTS Dale <br />NOTES FOR ALL DRAWINGS <br />OCPD = OVERCURRENI PROTECTION DEVICE <br />NATIONAI ELECTRICAL CODE' REFERENCES <br />sHowN AS (NEC ,(XXX) <br />INVERTER RATINGS (Guido Soction 4) <br />. TNVERTER MAKE Solaf edge <br />rNvER'rER MoDEL SE7600H-US <br />MAx Dc voLT RATTNG 48 <br />MAx PowER @ 4ooc 3.8 <br />*or,*o. o" uorroo, lzco <br />MAX AC CURRENT <br />MAX OCPD RATING <br />SIGNS-SEE GUIDE SECTION 7 <br />SIGN FOR DC OISCONNECT <br />PHOIOVOLTAIC POWER SOURCE <br />PV MODULE RATINGS @ STC (Guide Soction 5) <br />MoouLE MAKE Jinko Solar <br />MooULEMoDEL JKM290M-608 <br />MAX POWER,POINT CURRENT IIMP) <br />MAX POWER.POINT VOLTAGE {VUP) <br />oPEN-CTRCUTT VOLTAGE (V@l <br />SHORT-CIRCUIT CURRENT IIsC) <br />MAX SERIES FUSE iOCPD) <br />MAXTMUM POWER (Pe) <br />MAX VOLTAGE (TYP 6OOVrc) <br />VOC TEMP COEFF (rnV/'CO or %PC!) <br />IF COEFF SUPPLIEO CIRCLE UNITS <br />9.02 <br />32.2 <br />.38.8 <br />9.78 <br />15 <br />290 <br />i <br />1000 <br />L <br />0.29 <br />RAIED MPP CURRENT NA A <br />RATED MPP VoLTAGE NA .J <br />IVAx SYSTEM VoLTAGE NA V <br />unx crncurr cunneu NA a <br />WARNING: ELECTRICAL SHOCK <br />HAzARO_LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />V <br />SIGN FOR INVERTER OCPD AND <br />AC DISCONNECT (lF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION12.5 <br />NOTES FOR ARRAY CIRCUIT WIRING (Gurde Section 5 and 8 and App€ndix D) <br />1 ) LOWEST EXPECT AMBIENT TEMPERATURE AASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION LOWEST EXPECTED AMBIENT TEMP r "C <br />2,) HIGHEST CONTINUOUS AMEIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2'l" ORY AULA TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCAIION HIGHEST CONTINUOUS TEMPERATURE !, .I <br />2 ) 2OO5 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEEO <br />4/"C IN THE UNITEO STATES (PALM SPRINGS, CA IS 44,10C), FOR LESS THAN 9 <br />CURRENI.CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST O 5'ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47'C OR LESS (AfL OF UNITED STAIES), <br />a) 12 AWG gOC CONOUCTORS ARE GENERALI-Y ACCEPTABLE FOR MOOULES <br />wlTH lsc OF 7 68 AMPS OR LESS WHEN PROTECTEO aY A t2-AMP OR SMALLER <br />FUSE, <br />b) 1O AWG, gO'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WTH Isc OF 9 6 AMPS OR LESS WHEN PROTECTEO BY A lSAMP OR SMALLER <br />FUSE, <br />NOTES FOR INVERTER CIRCUITS (Guide Soclion 8 and 9)i <br />1)IF UTILITY REOUIRES A VISIELE€REAX SWITCH, OOES THIS SWITCH MEET THE <br />REOUIREMENT? YESO NOtr N/AI <br />2) IF GENERATION METER REQUIRED. OOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES E NO tr }I/A I <br />3) S|ZE PHOTOVOLTATC POWER SOURCE (DC)CONDUCTORS aASED ON MAX <br />CURRENT ON NEC 690,53 SIGN OR OCPD RATING AT OISCONNECT <br />4)SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (S€a Guide S€clion 9) <br />5) TOTAL OF , INVERTER OCPD(S) ONE FOR IACH INVERTER DOES TOTAL <br />supply BREAK-EFS coMpry wtrH r20% BUSaAR ExcEpTloN lN 690 64(aX2Xa)? <br />YES E NO E] <br />Ac ourPUT CURRENT 15.83 a <br />NOMINAL AC VOLTAGE 24O v <br />THIS PANEL FEO BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />15 n]- <br />t- <br />c <br />(,cd <br />::c! <br />o <br />=o