Laserfiche WebLink
Customer AR <br />CustomerAddress <br />3591617 <br />3617 W Kent Ave <br />Santa Ana, CA <br />Utility Company Name <br />Utility Account Number <br />Electrical Meter Number <br />Estimated Annual CONSUMPTION <br />Estinlated Annual PRODUCTION <br />SCE <br />3-007-7187-22 <br />222013-406013 <br />7120 <br />6236.6 <br />Offset: 87-5% <br />Number of Panels <br />Total System Size/DC Source Rating/Total Array Output CDC Watts) <br />Inverter Ampere Rating (Amps AC) <br />Number of Phases <br />'Inverter Voltage Rating <br />Nominal DCVolts <br />Inverter Power Factor (%) <br />Module Manufacturer and Model Number <br />Power Rating per Module (DC Watts) <br />Inverter Manufacturerand Model Number <br />Inverter Continuous AC Rating (AC Watts) <br />Inverter Peak Efficiency (%) <br />17 <br />4250 <br />0.9 <br />1 <br />240 <br />30.2 <br />0.95 <br />Yingli Energy YL250P-29b <br />250 <br />Enphase M215-60-2LL-522 <br />215 <br />96.3% <br />Totals <br />;Numbefof Modules/Inverters <br />System Size/DC Source Rating/Array Output (DC Watts) <br />Total Invefter Ratihg (kW AC) <br />Total Inverter Output (AC Watts) <br />Estimated Production <br />Building Permit Valuation <br />Electrical Perfnit Valuation <br />Total Valuation <br />@ $5.00/Watt:5.00 <br />17 <br />4250 <br />0.215 <br />215 <br />6236.6 <br />$ 850.00 <br />$ 20,400.00 <br />$ 21,250.00 <br />$ 21,250.00 <br />Building Permit Valuation per watt $ 0.20 <br />Electrical Permit Valuation per watt $ 4.80 <br />Const ra i nt:Electrical <br />Customer Estimated Monthly Usage:(Total annual usage: 7120 kWh) <br />January Febfuary March April <br />496 476 558 480 <br />May June July August <br />589 540 589 682 <br />September October November December <br />930 682 540 558