Laserfiche WebLink
MODULE DETAIL <br />Yingli Energy YL250P-296 <br />SOLAR MODULE <br />Inverter Ratihgs (Guide Section® <br />Inverter Make/Model Enphase M215-60-2LL-S2x-ZC <br />Max DC Volt Rating 45 Volts <br />Max Power @ 40°C 215 Watts <br />Norninal AC Voltage 240 Volts <br />Max AC Current o.g Amps <br />Max OCPD Rating 20 Amps <br />O Conduit and Conductor Schedule <br />Tag Description Wire Gauge #of Conductors Conduit Type Conduit Size <br />Enphase engage cable - THWN-2 12:AWG 4 N./A - Free Air NA - Free Air <br />1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 10 AWG 3 EMT 0'-1" <br />2 THWN-2 - Ground :BAWG 1 EMT 041 <br />3 THWN-2 8 AWG 3 PVC:0'-1" <br />3 THWN-2,- Ground 8'AWG 1 PVC 041" <br />Enphase M215-60-2LL-32*-ZC <br />MICRO-INVERTER AT <br />EACH MODULE, ATTACHED <br />WITH ZEP HARDWARE <br />#6 BARE CU GROUND »(GROUNDING MODULE - <br />&INVERTER) <br />MICRO-INVERTER CONNECTION - | <br />ENPHASE ENGAGE TRUNK CABLE <br />NOTE: ALL PLACARDS SHALL HAVEA RED BACKGROUND, <br />MINIMUM 3/8" LETTER HEIGHTS, ALL CAPITAL LETTERS, <br />ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE <br />WEATHER MATERIAL SUITABLE FOR THE ENVIROMENT. <br />Max Number of Panels/Circuit 17 <br />NOTES: FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />10 IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS <br />SWITCH MEET THE REQUIREMENTS? <br />YES NO X NA <br />2.) IF GENERATION METER REQUIRED, DOES THIS METER <br />SOCKET MEET THE REQUIREMENTS? <br />YES NO X NA <br />3.) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS <br />BASED ON MAX CURRENT ON SIGN OROCPD <br />RATING AT DISCONNECT. <br />4) SIZE INVERTER OUTPUT (AC) CONDUCTORS ACCORDING <br />TO INVERTER OCPD AMPERE RATING (See Guide Section 9). <br />5.) TOTAL OF 1- INVERTER OCPDCs). ONE FOR EACH <br />PV CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY <br />WITH 120% BUSBAR EXCEPTION X YES NO <br />Signs (See Guide Section 7) <br />Sign for inverter OCPD and AC Disconnect: <br />If Main Disconnect is <br />Solar PV System AC Point of rated less than the <br />Connection Busbar rating: <br />AC Output Current 19.125000 Amps "Caution-Solar <br />Nominal AC Volt.240 Volts Connection. Do Not <br />increase size of main <br />THIS PANEL FED BY MULTIPLE SOURCES disconnect" <br />(UTILITY AND SOLAR) <br />PV Module Ratings @ STC (Guide Section 5) <br />Model Make/Model Yingli Emergy YL250P-29b <br />Max Power=Point Current (Imp)8.11 Amps <br />Max Power-Point Voltage (Vmp)30-2 Volts <br />Open-Circuit Voltage (Voc)37.8 Volts <br />Short-Circuit Current (Isc)8.63 Amps <br />Max Series Fuse (OCPD)15 Amps <br />Nominal Maximum Power at STC (Pmax)240 Watts <br />Maximum System Voltage 1000(IEC)/600(UL) <br />Voc Temperature Coefficient -0.33 %/9 <br />NOTES FOR,ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): <br />1.) Lowest expected ambient temperature based on ASHRAE minimum mean extreme dry <br />bulb temperature:for ASHRAE location most similar to installation location: -1.5°C <br />2.) Highest continuous ambient temperature based on ASHRAE highest month 2% dry bulb <br />temperature for ASHRAE location most similar to installation location- 37°C <br />3.) 2005 ASHRAE fundamentals 2% design temperatures do not exceed 47°C in the UAited <br />States (Palm Springs, CA is 44.1°C). For less than 9 current-carrying conduetors in <br />roof-mounted sunlit conduit at least 0.5" above roof and using the outdoor design <br />temperature of 47°C or less (all of United States). <br />a.) 12 AWG: 90°C conductors are generally acceptable for modules with Isc of 7.68 Amps <br />orless when protected by a 12-Amp or smaller fuse. <br />b.) 10 AWG, 90°C conductors are generally acceptable for modules with Isciof 9.6 Amps <br />of less when protected by a 15-Amp or smaller fuse. <br />Z <br />1: <2430. glt.·*' S'·EPOINT OF DELIVERY 17®osed Cor,00AND INTERCONNECTION .4 /„/,111,1 ill' <br />% i...Oody ... y...:2-2 <br />VISIBLE/LOCKABLE <br />'KNIFE' A/C F <br />PV CIRCUIT 1: 17 MODULES/PARALLEL 43/PO DISCONNECT <br />EXISTING <br />240V/100A <br />LOAD-CENTER <br />1 1 <br />100,(-·1 <br />4 <br />3Nll-L 123 9¥Ia <br />, Siemens <br />/1 1 # LNF222R2 \ 60A/240V <br />NOTE: NEUTRAL CONDUCTOR(S) OMITTED FOR CLARITY \Ely JUNCTION/El.0 \ UNFUSED0 <br />ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR.BOX NEMA3 <br />WARNING LABELS WITH WHITE LETTERS/RED BACKGROUND WILL BE <br />PROVIDED ON A/C DISCONNECT <br />gE 1.0/ <br />7IVI <br />DRAWN BY: SH AR 3591617 <br />Last Modified: 3/6/2014 <br />UTILITY ACCOUNT NUMBER: 3-00717187-22