Laserfiche WebLink
3 1 Inverter Ratings (Guide Section 4) <br />MODULE DETAIL Inverter Make/Model Enphase M215-60-2LL-S2»ZC <br />Max DC Volt Rating 45 Volts <br />Yingli Ehergy YL250P-29b Max Power @ 40C 215 Watts <br />SOLAR MODULE Nominal AC Voltage 240 Volts <br />Max AC Current 0,g Amps <br />Max OCPD Rating 20 Amps <br />Max Number of Panels/Circuit 17 <br />NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9):1 1 1.) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS <br />SWITCH MEET THE REQUIREMENTS?Enphase M215-60-2LL-SZx-ZC <br />YES NO X NAMICRO-INVERTER ATEACH MODULE, ATTACHED {) ]2.) IF GENERATION METER REQUIRED, DOES THIS METER <br />WITH ZEP HARDWARE 'SOCKET MEET THE REQUIREMENTS? <br />YES NO X NA <br />3.) SIZE PHOTOVOLIAIC POWER SOURCE (DC) CONDUCTORS <br />BASED ON MAX CURRENT ON SIGN OR OCPD <br />RATING AT DISCONNECT. <br />4.) SIZE INVERTER OUTPUT (AC) CONDUCTORS ACCORDING <br />MICRO-INVERTER CONNECTION .O TO INVERTER OCPD AMPERE RATING (See Guide Section 9).ENPHASE ENGAGE TRUNK CABLE- . 5.) TOTAL OF 2 INVERTER OCPD(s). ONE FOR EACH <br />PV CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY <br />WITH 120% BUSBAR EXCEPTION X YES NO <br />#6 BARE CU GROUND <br />(GROUNDING ARRAY)'-Signs (See Guide Section 7) <br />Sign for inverter OCPD and AC Disconnect: <br />If Main Disconnect is <br />Solar PV System AC Point of rated less than the <br />Connectjon Busbar rating: <br />AC Output Current 22.500000 Amps "Caution-Solar <br />Nominal, AC Volt.240 Volts . Connection. Do Not <br />incr.ease size of main <br />THIS PANEL FED BY MULTIPLE SOURCES disconnect" <br />(UTILITY AND SOLAR) <br />Tag Description Wire Gauge #:of Conductors Conduit Type Conduit Size <br />-1 Enphase ehgage cable - TH\AN-2 12 AWG 4 14/A - Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/G E¢) 6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 10 AWG 6 EMT 01-1" <br />2. TH\AN-2 - Ground 8 AWG 1 EMT 0'-1" <br />3: TH\AN-2 8 AWG 3 PVC 0'-1 <br />i 3 | THWN-2 -Ground 8 AUG 1 PVC 0'-1" <br />(D <br />0 <br />C <br />PV Module Ratings @ STC (Guide Section,5)0 -i <br />9¤ cD E <br />Model Make/Model Yingli Energy YL250P-29b lai·%2Max Power-Point Current (Imp)8.11 Amp*s (DI LMax Power-Point Voltage (Vmp)30.2 Volts <br />Open-Circuit Voltage (Voc)37.8 Volts <br />Short-·Circuit Current (Isc)8.63 Amps ) <br />Max, Series Fuse (OCPD)15 Amps L G <br />0 <br />Nominal'Maximum Power atjSIC (Pinax)240 Watts <br />LL <br />Maximum System Voltage 1000(IEC)/600(UL) <br />Voc Temperature Coefficient -0.33 %/°C <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix Dj: <br />1 ) Lowest expected ambient temperature based on ASHRAE minimum mean extreme dry <br />bulb temperatore for ASHRAE location mosf similar to installation location: -1.5°C <br />23 Highest continuous ambient temperature based on ASHRAE highest month 2% dry bulb <br />temperature for ASHRAE location most similar to installation location: 37°C <br />3.) 2005 ASHRAE fundamentals 2% design temperatures do not exceed 47°C in the United <br />States (Palm Springs, CA is 44.1°C). For less than 9 current-carrying conductors in <br />roof-mounted sunlit conduit at least 0.5" above roof and using the outdoor design <br />ten,perature of 47°C or tess (all of United States) <br />a.) 12 AWG: 90°C conductors are generally acceptable- for modules with Isc of 7.68 Amps <br />or less when protected by a 12-Amp or smaller fuse. <br />b.) TO AWG, 90°C conductors are generally acceptable for modules with isc of 9.6 Amps <br />or less when protected by a 15-Amp or smaller fuse.... <br />NOTE' ALL PLACARDS SHALL HAVE A RED BACKGROUND, <br />MINIMUM 3/8" LETTER HEIGHTS, ALL CAPITAL LETTERS, <br />ARIAL OR SIMILARFONT, NON BOLD, REFLECTIVE <br />WEATHER MATERIAL SUITABLE FOR THE ENVIROMENT. <br />PV CIRCUIT 1: 11 MODULES/PARALLEL <br />n <br />0 0 0 <br />POINT OF DELIVERY <br />AND INTERCONNECTION <br />COMBINER VISIBLE/LOCKABLE MY!/ <br />PANEL 'KNIFE' A/C <br />PV CIRCUIT 2· 9 MOn[]l FR/PARALLEL 1-/ ·125A/240V DISCONNECT <br />1 EXISTING <br />240V/200A <br />4 LOAD-CENTER <br />2 <br />2CD.H <br />e e 15A <br />3 2 <br />- 11 . r A- 1 1 1-."„=18=79.%<C <br />P fe N.......:44 4-LU 05e <Duel.Z O <br />E < <br />. - 46 <br />E. uran·Fr-r--Siemens _17 1 ;2 SHEET <br />--1- <br />/ 1 \ 3 #LNF222R 9 -1-'; / ..0· 97314'/*·NUMBER: <br />60A/240V (04 12 9> I.*®.*.#_ 0 4, <br />NOTE. NEUTRAL CONDUCTOR(S) OMITTED FOR CLARITY i )JUNCTION BOX \\ E 1.0 / <*E 1.0 /1 \ E 1.0 UNFUSED .°NzssyALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR. \ /WITH IRREVERSIBLE \ / , NEMA3 <br />WARNING LABELS WITH WHITE LETTERS/RED BACKGROUND WILL BE GROUNDSPUCE \ <br />PROVIDED ON A/C DISCONNECT LU <br />IOA 30A