My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10181089_3604 W. ROBERTS - Plan
PBA
>
Building
>
Plans
>
R
>
Roberts Dr
>
3604 W Roberts Dr
>
10181089_3604 W. ROBERTS - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 12:52:43 AM
Creation date
10/25/2020 5:22:13 PM
Metadata
Fields
Template:
Plan
Permit Number
10181089
Full Address
3604 W Roberts Dr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1%,Inverter Ratings (Guide Section 4) 0 Cond.lit and Conductor Schedule <br />MODULE DETAIL Jnverter Make/Model Enphase M215-60-2LL-82x-ZC <br />Max DC Volt Rating 45 Volts <br />Yingli Energy YL250P 29b Max Power @ 40°0 - 215 Watts <br />SOLAR MODULE Nominal AC Voltage 240 Volts <br />- <br />Max AC Current 0.9 Amps <br />Max OCPD Rating 20 Amps <br />Tag Description Wire Gauge #of Conductors Conduit Type Conduit Size <br />1 Enphase engage cable - THWN-2 12 AWG 4 N/A -Free Aif NA - Free Air <br />i Bare Copper Ground (EGC/GEC)6 AWG 1 NUL Free Air N/A - Free Air <br />2 THWN-2 10 AWG 3 EMT 0'-1- <br />2 THWN-2 - Ground 8 AWG 1 EMT oILl• <br />3 THWN-2 8 AWG 3 PVC 01-1 " <br />3; THWN-2 - Ground 8:AWG 1 PVC 00.1- <br />Enphase M215-60-2LL-S2x-ZC <br />MICRO-INVERTER ATEACH MODULE, ATTACHED <br />WITH ZEP HARDWARE <br />#6 BARE CU GROUND <br />(GROUNDING MODULE - <br />&INVERTER)1,1 <br />MICRO-INVERTER CONNECTION - i <br />ENPHASE ENGAGE TRUNK CABLE <br />NOTE: ALL PLACARDS SHALL HAVE A RED BACKGROUND, <br />MINIMUM 3/8" LETTER HEIGHTS, ALL CAPITAL LETTERS, <br />ARIAL ORSIMILAR FONT, NON BOLD: REFLECTIVE <br />WEATHER MATERIAL SUITABLE FOR IHE ENVIROMENI. <br />Max Number of Panels/Circuit 17 <br />NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />1 ) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS <br />SWITCH MEET THE REQUIREMENTS? <br />YES NO X NA <br />2.) IF GENERATION METER REQUIRED, DOES THIS METER <br />SOCKET MEET THE REQUIREMENTS? <br />YES NO X NA <br />3.) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS <br />BASED ON MAJ< CURRENT ON SIGN OR OCPD <br />RATING AT DISCONNECT. <br />4.) SIZE INVERTER OUTPUT (AC) CONDUCTORS ACCORDING <br />TO INVERTER OCPD AMPERE RATING (See Guide Section 9). <br />5.) TOTAL OF 1 INVERTER OCPD(s). ONE FOR EACH <br />PV CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY <br />WITH 120% BUSBAR EXCEPTION X YES NO <br />Signs (See Guide Section 7) <br />Sigh for inverter OCPD and AC Disconnect: <br />i If Main Disconnect isSolar PV System AC Point of rated less than the <br />Connection Busbar rating: <br />AC Output Current 15.750000 Amps "Caution-Solar <br />Nominal AC Volt.240 Volts Connection. Do Not <br />increase size of main <br />THIS PANEL FED BY MULTIPLE SOURCES disconnect" <br />(UTILITY AND SOLAR) <br />PV Module Ratings @ STC (Guide Section 5) <br />Model Make/Model Yingli Energy YL250P-29b <br />Max Power-Point Current (Imp)8.11 Amps <br />Max Power-Point Voltage (Vmp)30.2 Volts <br />Open-Circuit Voltage (Voc)37.8 Volts <br />Short-Circuit Current (Isc)8.63 Amps <br />Max Series Fuse (OCPD) 15 Amps <br />Nominal Maximum Power at STC (Pmax)240 Watts <br />Maximum System Voltage 1000(JEC)/600(UL) <br />Voc Temperature Coefficient -0.33 %/°C <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): <br />1.) Lowest expected ambient temperature based on ASHRAE minimum mean extreme dry <br />bulb temperature for ASHRAE location most similar to installation location: -1.5.°C <br />2.) Highest continuous;iambient temperature based on ASHRAE highest month 2% dry bulb <br />temperature for ASHRAE location most similar to installation location: 37°C <br />3.) 2005 ASHRAE fundamentals 2% design temperafures do not exceed 47°C in the United <br />States (Palm Springs, CA is 44.1°C). For less than 9 current-carrying conductors in <br />roof-mounted sunlit conduit at least 0.5" above roof and using the outdoor design <br />temperature of 47°C or less (all of United States). <br />a.) 12 AWG, 90°C conductors are generally acceptable for modules with Isc of 7.68 Amps <br />or less when protected by a 12=Amp or amaller fuse. <br />b.) 10 AWG, 90°C conductors are generally acceptable for modules with Isc of 9.6 Amps <br />or less when protected by a 15-Amp or smaller fuse. <br />POINT OF DELIVERY <br />AND INTERCONNECTION <br />PV CIRCUIT 1: 14 MODULES/PARALLEL <br />n 0 0 <br />Ok> 90 <br />2 <br />E 1.0 <br />VISIBLE/LOCKABLE <br />'KNIFE' A/C <br />DISCONNECT <br />EXISTING <br />1C=ZIC-C 240V/100A <br />LOAD-CENTER <br />111" <br />11® lie <br />241 <br />20A Fl <br />1 + <br />00",1,111,4,/,/4p _ of Ca//6, 4, <br />11 <br />Siemens <br />#LNF222R/1\60A/240V < <br />NOTE: NEUTRAL CONDUCTOR(S) OMITTED FOR CLARITY ./' JUNCTION \ <br />ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR.BOX ,UNFUSED <br />NEMA3 <br />WARNING LABELS WITH WHITE LETTERS/RED BACKGROUND WILL BE <br />PROVIDED ON A/C DISCONNECT <br />1E1.0/ <br />1 ... 0 &C <br />9€2&9,94/,1,111 1,1,%... <br />fY UIAL,MAIVI <br />DRAWN BY: NU | AR.3582819 <br />Last Modified: 3/5/2014 <br />UTILITY ACCOUNT NUMBER: 3-022-8965-32
The URL can be used to link to this page
Your browser does not support the video tag.