Inverter Ratings (Guide Section 4) <br />MODULE DETAIL ,Inverter Make/Model Enpliase M215-60-2LL-S2x-ZC <br />Max DC Volt Rating 45 Volts <br />Yingli Energy YL245P-29b Max Power @ 40'C 215 Watts <br />SOLAR MODULE Nominal AC Voltage 240' Volts <br />- <br />Max AC Curfent 0.9 Amps <br />Max OCPD Rating 20 Amps <br />O Conduit and Conductor Schedule <br />Tag Description Wire Gauge #of Conductors Conduit Type Conduit Size <br />1 Eriphase engage cable - THWN-2 12 AWG 4 N/A -<Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/GEC):6 AWG 1 N/A - Free Air N/A - Free Aif <br />2: THWN-2 10 AWG 6 EMT 0'-1 " <br />2 THWN-2 - Ground BAWG 1 EMT 0'-1" <br />3 THWN-2 8 AWG 3 PVC 0'-1" <br />3; THWN-2 - Ground 8 AWG 1 PVC 0'-1" <br />Enphase M215-60-2LL-S2x-ZC <br />MICRO-INVERTER ATEACH MODULE. ATTACHED WITH NISI HARDWARE <br />#6 BARECU GROUND l \5\(GROUNDING MODULE -- <br />&INVERTER)211 <br />MICRO-INVERTER CONNECTION - | <br />ENPHASE ENGAGE TRUNK CABLE <br />NOTE: ALL PLACARDS SHALL HAVE A RED BACKGROUND, <br />MINIMUM 3/8" LETTER HEIGHTS. ALL CAPITAL LETTERS, <br />ARIAL OR SIMILAR FONT, NON BOLD. REFLECTIVE <br />WEATHER MATERIAL SUITABLE FOR THE ENVIROMENT. <br />Max Nomber of Panels/Circuit 17 <br />NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />1.) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS <br />SWITCH MEET IHE REQUIREMENTS? <br />YES NO X NA <br />2.) IF GENERATION METER REQUIRED. DOES THIS METER <br />SOCKET MEET THE REQUIREMENTS? <br />YES NO X NA <br />3.) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS <br />BASED ON MAX CURRENT ON SIGN OR OCPD <br />RATING AT DISCONNECT. <br />4.) SIZE INVERTER OUTPUT (AC) CONDUCTORS ACCORDING <br />TO INVERTER OCPD AMPERE RATING (See Guide Section 9). <br />5.) TOTAL OF L INVERTER OCPD(s). ONE FOR EACH <br />PV CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY <br />WITH 120% BUSBAR EXCEPTION X YES NO <br />Signs (See Guide Section 7) <br />Sign for inverter OCPD and AC Disconnect: <br />If Main Disconnect is <br />Solar PV System AC Point of rated less than the <br />Connection Busbar rating: <br />AC Output Current 30.375000 Arnps ·'Caution-Solar <br />Nominal AC Volt.24.0 Volts Connection. Do Not <br />increase size of main <br />THIS PANEL FED BY MULTIPLE SOURCES disconnect" <br />(UTILITY AND SOLAR) <br />PV Module Ratings @ STC (Guide Section 5) <br />Model Make/Model Yingli Energy YL245P-29b <br />Max Power-Point Current (Imp)8.11 Amps <br />Max Power-Point Voltage (Vmp)30.2 Volts <br />Open-Circuit Voltage (Voc)37.8 Volts <br />Short-Circuit Current (]sc)8.63 Amps <br />Max Series Fuse (OCPD)15 Amps <br />Nominal Maximum Power at STC (Pmax)240 Watts <br />Maximum System V.oltage 1000(IEC)/600(UL) <br />Voc Temperature Coefficient -0.33 %/°C <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): <br />1.) Lowest expected; ambienf temperature based on ASHRAE minimum mean extreme dry <br />bulb temperature for ASHRAE location most similar to installation location: -1.5°C <br />2.) Highest continuous ambient temperature based on ASHRAE highest month 2% dry bulb <br />temperature for ASHRAE location most similar to installation location: 37°C <br />3.) 2005 ASHRAE fundamentals 2% design temperatures do not exceed 47°C in the United <br />States (Palm Springs. CA is 44.1°C). For less than 9 current-carrying conductors in <br />roof-mounted sunlit conduit at least 0.5" above roof and using the outdoor design <br />temperature of 47°C or less (all of United States). <br />a.) 12 AWG, 909C conductors are generally acceptable for modules with Isc of 7.68 Amps <br />or less when protected by a 12-Amp or smaller fuse. <br />b.) 10 AWG, 90°C conductors are generally acceptable for modules with Isc of 9.6 Amps <br />or less when protected by a 15-Amp or smaller fuse. <br />PV CIRCUIT 1: 15 MODULES/PARALLEL <br />11 @ e <br />e <br />1 <br />Cody E. Oram <br />State of California Licensed Contractor ' <br />No. 973756 Class C-10 & 646 <br />POINT OF DELIVERY <br />AND INTERCONNECTION <br />-1 COMBINER VISIBLE/LOCKABLE L- <br />PANEL 'OPEN BLADE' A/C <br />PV CIRCUIT 2: 12 MODULES/PARALLEL 125A/240V DISCONNECT <br />'00234*44 <br />A <br />11 NEW <br />C 240V/125A <br />4 LOAD-CENTER20A <br />IDA 1 1 <br />40& IZI <br />L <br />1 ./3\ <br />Siemens <br /># LNF222R <br />60A/240V r-§ <br />SOLAR BREAKER <br />SHALL BE PLACED AT <br />THE EXTREME <br />OPPOSITE SIDE OF <br />THE UTILITY SUPPLY <br />NOTE: NEUTRAL CONDUCTOR(S) OMITTED FOR CLARITY \&15ALL INV.ERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR. <br />WARNING LABELS WITH WHITE LETTERS/RED BACKGROUND WILL BE <br />PROVIDED ON A/C DISCONNECT <br />'JUNCTION BOX < <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />19 423 FUSED » <br />NEMA) <br />- DIAGRAM <br />barta Ana, UA 92/U4 <br />DRAWN BY: SH | AR 3605546 <br />Last Modified: 5/29/2014 <br />UTILITY ACCOUNT NUMBER· 3-006-1215-26