Laserfiche WebLink
Inverter Ratings (Guide Section 41 <br />MODULE DETAIL |Inverter Make/Model Enphase M215-60-2LL-S2x-ZC <br />Max DC Volt: Rating 45 Volts <br />Yingli Energy YL250P-29b 1 Max Power @ 40°C 2,M Watts <br />SOLAR MODULE |Nominal AC Voltage 240 Volts\\\1 Max AC Current 0.9 Amps <br />Max OCPD Rating 20 Amps <br />O Cond lit and Corductor Schedde <br />Tag Desgiption Wire Gauge #of Conductors:Conduit Type,Condi,il Size <br />:1 Enphase engage cable - THWN-2 12 AWG 4 N,·A -Free Air N/A - Free Air <br />1 Bare Ctipper Ground (EGC/GEC) 6 AWG 1 N/A - Free All N/A - Free Air <br />2 THWN-2 10 AWG 3 EMT 0'21" <br />2 THWN-2 - Ground 8·AWG 1 EMT 01-1 <br />3 THWN-2 8 AWG 3 PVC 0'-1 " <br />3 THWN-2 - Ground 8 AWG 1: PVC 0'-1 <br />Max Numberof Panels/Circuit 17 <br />NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9) <br />1.) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS 1 <br />Enphase M215-60-2LL-S2x-ZC SWITCH MEET THE REQUIREMENTS? <br />MICRO-INVERTER AT -YES NO X NA <br />EACH MODULE: ATTACHED 2.) IF GENERATION METER REQUIRED,:DOES THIS METER <br />WITH ZEP HARDWARE SOCKET MEET THE REQUIREMENTS? <br />YES NO X NA <br />3.) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS <br />BASED ON MAX CURRENT ON SIGN OR OCPD <br />RATING AT DISCONNECT. <br />4.) SIZE INVERTER OUTPUT (AC) CONDUCTORS ACCORDING <br />MICRO-INVERTER CONNECTION 1 TO INVERTER OCPD AMPERE RATING (See Guide Section 9).ENPHASE ENGAGE TRUNK CABLE- <br />5.) TOTAL OF 1.- INVERTER OCPD(s). ONE FOR EACH <br />PV CIRCUIT. DOES TOTAL SUPPLY BREAKERS COMPLY <br />] WITH 120% BUSBAR EXCEPTION X YES NO <br />#6 BARE CU GROUND <br />(GROUNDING ARRAY)Signs (See Guide Section 7) <br />Sign for inverter OCPD and AC Disconnect:If Main Disconnect is <br />Solar PV System AC Point of rated less than the <br />Connection Busbar rating: <br />AC Output Current 19.125000 Amps "Caution-Solar <br />Nominal AC Volt.240 Volts Connection. Do Not <br />increase size of main ' <br />THIS PANEL FED BY MULTIPLE SOURCES disconnect" <br />(UTILITY AND SOLAR) <br />PV Module Ratings @ STC (Guide Section 5)(D -2 E <br />Model Make/Model Yingli) Energy YL250P-29b E C·gl <br />0 $<EMax Power-Point Current (Imp)8.11 Anips O 3 9-z <br />Max Power-Point Voltage (Vmp)30.2 Volts Al -/i D <br />Open-Circuit Voltage (Voc)37.8 Volts ..00 1.0 <br />w' 5 20 <br />Short-Circuit Current (Isc)8.65 Amps a) (D %< <br />Max Series Fuse (OCPD)15 Amps E un <br />Nominal Maximum Power!at STC (Pmax)240 Watts m 2 <br />Maximum System Voltage 1000(IEC)/600(UL) 5 <br />Voc Temperature Coefficient -0.33 %26 <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): <br />1.) Lowest expected ambient temperature based on ASHRAE minimum mean extreme dry <br />bulb temperature for ASHRAE location most similar to installation location. -1.5°C <br />2.) Highest continuous ambient temperature based on ASHRAE highest month 2% dry bulb <br />temperature for ASHRAE location most similar to installation location· 37°C <br />3.) 2005 ASHRAE fundamentals 2% design temperatures do not exceed 47°C in the United <br />States (Palm Springs, CA is 44.1'C). For less than 9 current-cartying conductors in <br />roof-mounted sunlit conduit at least 0.5" above roof and using the outdoof design <br />temperature of 47°C or less (all of United States). <br />a.) 12 AWG, 90''C conductors are generally acceptable for modules with Isc of 7.68 Amps m <br />or less when protected by a 12-Amp or smaller fuse.0 <br />b.) 10 AWG, 90°C conductors are genetally acceptable for modules with Isc of 9.6 Amps a01 <br />or less when protected by a 15-Amp or smaller fuse.0- A <br />.. <br />C <br />NOTE: ALL PLACARDS SHALL HAVE A RED BACKGROUND,47- <br />MINIMUM 3/8" LETTER HEIGHTS, ALL CAPITAL- LETTERS, <br />ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE <br />WEATHER MATERIAL SUITABLE FOR THE ENVIROMENT.e>55 '8Y':4,4 0) <br />20 0 -***fro. t.Cd <br />, .• AJJ-4 0- I•.Llj 4 <br />POINT OF DELIVERY ,g@-t,¢136Gy,t. oram 2- k €2 <br />- I . -9 0 # / <br />PV CIRCUIT 1: 17 MODULES/PARALLEL <br />- 0 [=) <br />4340 <br />e <br />AND INTERCONNECTION %50°·&?· 8731€*.•f <br />4 $A 0--00 CP **',rea CorM*>4,,'tl <br />VISIBLE/.LOCKABLE <br />'KNIFE' A/C <br />DISCONNECT <br />1 EXISTING <br />240V/100A <br />4 LOAD-CENTER <br />»>0/1CE.ilin SHEET <br />NAME: <br />20& 1=3Nll-L DIAG,R, <br />Y Siemens <br /># LNF222R/3-1 /2/ 60A/240v < <br />NOTE: NEUTRAL CONDUCTOR(S) OMITTED FOR CLARITY \\Ey JUNCTION/ UNFUSED <br />ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR.BOX NEMA3 <br />WARNING LABELS WITH WHITE LETTERS/RED BACKGROUND WILL BE <br />PROVIDED ON A/C DISCONNECT <br />SHEET <br />NUMBER: <br />E 1.0/In