Laserfiche WebLink
REMODEL AREA: 49.30 Sq.Ft. <br />GFI <br />NEW FIRST FLOOR PLAN <br />SCALE: 1/4" = 1' <br />D <br />A <br />T <br />E <br />BY <br />RE <br />V <br />I <br />S <br />I <br />O <br />N <br />S <br />SHEET NO. <br />E <br />X <br />I <br />S <br />T <br />I <br />N <br />G <br /> <br />R <br />O <br />O <br />F <br /> <br />P <br />L <br />A <br />N <br />YUVAL NISSIM-ROZNER <br />17351 GRESHAM ST <br />NORTHRIDGE CA 91325 <br />323-203-9700 <br /> DESIGN <br />A3 <br />06 - 01 - 2025 <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />31 <br />1 <br />7 <br /> <br />S <br /> <br />T <br />O <br />W <br />N <br />S <br />E <br />N <br />D <br /> <br />S <br />T <br />PR <br />O <br />P <br />O <br />S <br />E <br />D <br /> <br />R <br />E <br />M <br />O <br />D <br />E <br />L <br />I <br />N <br />G <br />CM <br />SD <br />LEGEND <br />SMOKE DETECTOR <br />CARBON MONOXIDE DETECTOR <br />EXISTING WALL <br />NEW WALL <br />EF EXHAUST FANS Sec. 4.506.1. <br />Mechanical exhaust fans which exhaust directly from bathtooms shall <br />be Energy star compliant, ducted to terminate outside the building, <br />and controlled by areadily accessible humidstat or awhole ventilation system. <br />SMOKE ALARM shall be interconnected hard-wired with batterybackup and shall be installed in accordance with NFPA 72 <br />CARBON MONOXIDE ALARM shall be interconnected hard-wired with battery backup <br />battery smoke alarm permitted in existing buildings where no <br />construction is taking place <br />smoke alarms shall be tested&maintained in accordance with <br />manufacturer instructions. smoke alarms shell be replaced <br />after 10 years from the date of manufactutred marked on the unit <br />conventional lonization smoke alarms that are solely battery <br />powered shall be equipped with a 10 year battery and have <br />a silence feature <br />battery carbon monoxide alarm is permitted in existing dwelling units <br />where no construction is taking place <br />a mechanical ventilation of 50-CFM intermittent or 20-CFM continuous <br />ventilation are provided <br />X42 <br />RECESSED LIGHT LED <br />SINGLE SWITCH <br />GFI 110V OUTLET 20 AMPGFI <br />S <br />All receptacle outlets shall be listed tamper-resistant receptacle per CEC <br />section 406.12(A) <br />be protected by a listed arc-fault circuit interrupter <br />All 120-V branch circuits supplying outlets in habitable rooms shall <br />(AFCI) -per CEC Sect. 210.12(A) <br />EF <br />S <br />SD <br />SD <br />CM <br />SD <br />CM