My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1522 W Richland St - Misc. Permit
PBA
>
Building
>
Permits
>
R
>
Richland St
>
1522 W Richland St
>
Misc.
>
1522 W Richland St - Misc. Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/27/2021 11:31:27 AM
Creation date
7/27/2021 11:22:41 AM
Metadata
Fields
Template:
Misc. Permit
Full Address
1522 W Richland St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERMIT PROCESS FOR SMALL-SCALE PV SYSTEMS <br />STANDARD STRINC SYSTEM <br />The information in this guideline is inrended ro help loczl jurisdictions and contractors identify when PV system insEllations <br />are simple, needing only a basic review and when an insEllation is more complex. It is likely thar 50 % -75 % ot all residential <br />systems will comply wirh these simple criteria. For projects that fail to meet the simple criteria, resolution sreps have been <br />suggested to provide as a path to Permit approval. <br />Requbed Information Jot Pefinit: <br />l. Sire plan showing location of major components on the property. This drawing need nor be exacdy to scale, but it <br />should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings <br />with a 3'perimeter space at ridge and sides may not need separate nre service review. <br />2. Electrical diagram showing PV array conhguration. wiring system, overcurrent protection, inverter, disconnects, <br />required signs. and ac connection to building (see supplied standard electrical diagram). <br />3. Specificalion sheers and installation manuals (if available) for all manufactured components including, but not <br />limited to, PV modules, inverter(s). combiner box. disconnects, and mounting sysrem. <br />Step 1 : Structural Review o[ PV Array Mounting System <br />Is the array to be mounted on a defined, permitted roof structure? Ey"" Eno <br />U No due to non-compliant rooJ or a ground. mount, submit completed worhsheet Jor the structure WKSI. <br />RooJ lnformatiott: <br />I . ls the roohng type lightweighr (Yes = composition, lightweight masonry, metal. etc...)COI\,,IP SHINGLE <br />U No, submtt completed worhsheet Ior rooJ structure WftS, (?Vo = heavy masonry, slate, etc...) <br />2. Does rhe roof have a single roof coveringz Eyes Eno <br />IJ No, submit completed worksheet Jor rool structure WI<SI . <br />3. Provide merhod and type of weatherproohng roof penetrations (e.g. nashing, caulk)FLASHING Y CAULK <br />M o unti ng Sy st em I nformation <br />l. Is the mounting structure an <br />beneath the module frames? <br />en <br />Yes <br />ineered product designed to mount PV modules with no more than an I8" gap <br />E tlo <br />IJ No, provide details oJ structural attachment certiled by s design professional. <br />2. For manufactured mounting systems, frll out information on the mounting system below <br />a. Mounting Sysrem Manulacturer 3!!lY99l1Product Name and p1r,6s1y CLASSIC COMPOSITION MOUNT <br />b. Total Weight of PV Modules 216 32;15 712 8 bs <br />c. Total Number of Attachment Point 24 <br />d. weight per Attachment Point {br6129 7 lbs(if grealer than 45 lbs,seewKSl) <br />e. Maximum Spacing Between AtEchment Points on a Rail 48 inches (see product manual for <br />maximum spacing allowed based on maximum design wind speed) <br />Total Surface Area of PV Modules (square feeo 945 ftr <br />Distributed Weight ol PV Module on Roof (b + 0 0.75 lbs/ftr <br />IJ distributed weight of the Pv system is greater than 5 lbstt', see wKSl. <br />Step 2: Electrical Review of PV System (Calculations lor Electrical Diagram) <br />In order for a PV system to be consideied for an expedited permit process, the following must aPply: <br />l. PV modules, urility-interactive inverters, and combiner boxes are identihed for use in PV systems. <br />2. The PV array is composed of 4 series strings or less per inverter. <br />3. The total inverler capacity has a continuous ac power output 13,440 Watts or less <br />4. The ac interconnection point is on the load side ol service disconnecting means (690.64(8)). <br />5. One ofthe smndard electrical diagrams (E L t , E | . I a, E I . 1 b, or E I . I c) can be used to accurately represent the PV <br />sysrem. lnteractive PDF diagrams are available at www.solarabcs.org/permitting. <br />Ftlt out the standard. electrical diagram completely. A guide to the electrical diagram is provided to help the applicant <br />understand each btank to lll in. t! the electrical system is more complex thdn the standard electrical diagram can elJectively <br />communicate, provide an alternative diagram with approPriate detail. <br />2 EXPEDITED PERMIT PRocTss FoR PV SYSTEMS <br />f. <br />g
The URL can be used to link to this page
Your browser does not support the video tag.