Laserfiche WebLink
October 1, 2013 SIGN COMPONENTS MANUAL (SAM) 54 <br />GEPS24-20, a temperature test is required when installed in an enclosure smaller than 13.5 by 6 by 4 inches, but the maximum <br />temperature on the output transformer by thermocouple is 90°C. <br />4. The output of these LED power supplies with Class 2 are acceptable for use in a damp and wet locations. <br />Power supplies with Class 2 outputs, Model GEXNPS30. <br />1. This component has outputs that qualify as being Class 2. <br />2, These components are intended for use in dry location only. <br />3. The transformer employs a Class B (130) Insulation System. <br />4. These components shall be installed in compliance with the enclosure and mounting requirements of the ultimate application. <br />5. The maximum room ambient temperature permitted by the manufacture is 50(C. <br />6. A Temperature Test is required of the power supply installed in an enclosure that measures less than 13.5 by 6 by 4 inches. The <br />maximum temperature on the output transformer by thermocouple is 110( C. <br />Power supplies with Class 2 outputs, Models GEPS24-180U, GE180/MVA/24T1-C <br />1. The maximum measured output voltage, current and power at the output of these models was found in compliance with the <br />limits for LPS output requirements and additionally evaluated to comply with Class 2 output criteria. <br />2. The transformer employ Class B insulation system. <br />3. Power Supply is intended for use in indoor Dry and Damp location only. <br />4. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. Adjacent power supplies shall be spaced at least 1 in. end to end and 4 in. in <br />any other direction. <br />5. Input and Output leads are style 1316, rated 600 V, 105°C, VW-1. Minimum No. 18 AWG. The suitability of input and output <br />connections shall be determined in each end use application. <br />6. The power supply was submitted and tested for a maximum manufacturer's recommended Tc point described in the table below. <br />If adjacent LED power supplies are spaced closer than 1 in. end to end or 4 in. side to side a temperature test shall be <br />conducted in the end use product. <br />Model Input Voltage, HZ Max. Case Temp @ Tc, °C Ambient, °C <br />GE180/MV/V24T1 -C, GEPS24-100-277, 60 80 60 <br />180U <br />LED Light Engine, Cat. Nos. 1110-WH-ZZ-TTK, 1110-RD-ZZ-TTK, catalog numbers where: "ZZ" representing assembly version: <br />followed by: "TT" - Optional - represents the color temperature of the LEDs in degree "K" Kelvin. Cat. Nos. 1111-XX-ZZ-Y-TTK, <br />catalog numbers may vary per nomenclature.: DOC representing color: RE), RC, YG, GL, SB, BL, WH, YA, WW, GR, PO, "ZZ" <br />representing assembly version; "Y" representing number of LEDs; followed by: "TT" - Optional - represents the color temperature of <br />the LEDs in degree "K" Kelvin. <br />1. These products are only suitable for connection to a Class 2 power source. <br />2. When units are connected to a Class 2/"LPS" circuit, they are not to draw a total wattage of greater than the secondary or output <br />rating of the Class 2f'LPS supply. <br />3. These products are suitable for use in dry, damp and wet locations. <br />4. The suitability of the LED Light Engine mounting means shall be determined in the end-use application. <br />5. The suitability of the LED Light Engine to be used without an additional electrical enclosure shall be determined in the end-use <br />application. <br />6. These products described in this section may be cut into segments per manufacture insulation instructions. <br />7. Units may be provided with UYMR2,3M type VHB double-sided adhesive tape. Tape must be utilized per UYMR2 "Conditions of <br />Use" as defined in the Sign Components Manual. <br />LED Driver with Class 2 Output, Models GEPS12D-60U, GEPS24D-80U. <br />1. These LED Drivers have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 output. <br />2. These products are provided with the following electrical ratings: <br />Model No.Input Voltage (V Input Freq Input Current Output Voltage Output Current Output <br />ac) (HZ) (A) 0/ dc) (A) Power (W) <br />GEPS24D-80U 100-277 50/60 1.1 24 3.3 80 <br />GEPS12D-60U 100-277 50/60 0.85 12 5.0 60 <br />3. The load powered by the Class 2 output of the LED drivers are suitable for use in dry, damp and wet locations. <br />4. In the end product, LED driver spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, and <br />minimum 2 inches spacing to top of enclosure. <br />5. In the end product, LED Drivers shall be located not less than 1 inch (25.4mm) apart when arranged end-to-end, and not less <br />than 4 inches (102mm) apart when arranged otherwise. <br />6. These products shall be enclosed in the end product. <br />7. The unit is intended for being used in permanently wired signs. <br />8. The suitability of output leads, rated No. 24 AWG minimum, rated 80°C minimum, 600 V, shall be determined in end product <br />use. <br />9. These units may provided with Dimming Input (Purple and Gray wires) to control output current range, the suitability shall be <br />determined in each end-use application. <br />10. These products are intended for use in dry and damp locations <br />LED Driver with Class 2 Output, Model 1 110PS-60S. <br />1. These LED drivers have been evaluated using resistive load resulting in the electrical input and output noted on page 1. <br />2. These LED drivers are provided with Class 2 output. <br />3. These LED drivers are intended to be operated in a maximum ambient (Ta) noted as below: <br />Model Ta (°C) <br />LD-60-UV-1214V 40 <br />4. These LED drivers are intended for use in dry and damp locations except that models LD-60-UV-1214V and LD-60-UV-1214V- <br />SC are suitable for dry location only. <br />5. These LED drivers are provided with 18 AWG AWM input and output leads. The suitability of the wiring and the need for a <br />suitable enclosure shall be considered in the end product.