Planning & Building Agoncy '- <br />Bullding Safety Diyislon <br />20 Civic Center Plaza <br />P.O. Box '1988 (M-19) <br />Santa Ana, CA92702 \\ r\ <br />(714) 647-s800 <br />$rww.santa-ana.org <br />RtCt\ RESIDENTIAL <br />..,,,a PHOTOVOLTATC <br />I\I J' CHECKLIST <br />sol-01 cBc 2016 <br />Solar Photovoltaic (PV) Ch6cklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11"x17" size. lf answorino NOtoanvof the ouestions. olan check shall be reouired. <br />Project Address:25 Cantera <br />Contractor Company Name:Blalock Electric & Solar <br />Contractor License Number: 915397 <br />gtr <br />trtr <br />trtrgtr <br />gtr <br />trtr <br />YES NO <br />E tr <br />trtr <br />Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV array be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to l0" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizonlal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum ol 2-112 incl'r <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans stamped and signed by a California <br />licensed professional engineer? (including proJect specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />'10 otr <br />I cortlfy under penalty of perlury under the laws of the State of Callforn <br />print Name: Nick Blalock Signature <br />Phone Number: 951-760-4638 <br />EmailAddress: info@blalock-electric.com <br />Rev: 8/29119 <br />Date 06t18t2020 <br />he above is true: <br />1 <br />trtr <br />2. <br />3. <br />4. <br />5. <br />6. <br />8. <br />9.