wh, ICC EVALUATION2 SERVICE Most Widely Accepted and Trusted
<br />ICC-ES Evaluation Report - ESR-1953P*
<br />Reissued May.11201*5
<br />This report is subject to renewal June 1, 2014.
<br />-.icc=es.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council®
<br />DIVISION: 10 00 00--SPECIALTIES
<br />Section: 10 73 00-Protective Covers
<br />REPORT HOLDER:
<br />MEIALS BUILDING PRODUCTS/
<br />-LATIUM USA TRADING, INC.
<br />5005 VETERANS MEMORIAL HIGHWAY
<br />HOLBROOK, NEW YORK 11741
<br />(714) 522-7852
<br />metalsbe.com
<br />EVALUATION SUBJECT:
<br />PAT[O COVERS, CARPORTS AND COMMERCIAL ROOF
<br />f SIRUCTURES
<br />1.0 EVALUATION SCOPE
<br />Compliance with the following codes:
<br />i • 2012,2009 and 2006'international Bu#ding Code' (IBC)
<br />:• 2012,: 2009-andi2006 international. Residential Code®
<br />- (IRC)
<br />Property evaluated:
<br />Structural
<br />2.0 USES
<br />The Metals Building Products freestanding and attached
<br />patio covers described in this report are used as patio
<br />covers complying with Appendix I of the IBC and Appendix
<br />H of the IRC. Freestanding and attached carports and
<br />commercial structures are used as covers where permitted
<br />by the applicable chapters and sections of the IBC,
<br />induding IBC Section 406.
<br />3.0 DESCRIPTION
<br />3.1 General:
<br />The freestanding and attached patio covers, carports and
<br />commercial structures must be constructed as indicated in
<br />this report and in accordance with the plans accompanying
<br />this report. The walls must be unenclosed on three
<br />sides for attached patio covers, and on four sides for
<br />freestanding patio covers, carports and commercial
<br />structures.
<br />3.2 Materials:
<br />3.2.1 Aluminum: The aluminum members are roll-formed
<br />and extruded shapes of various alloys and tempers,
<br />complying with Chapter 20 of the IBC and as specified in
<br />the plans accompanying this report.
<br />3.2.2 Steel: The steel members are various grades of
<br />galvanized steel complying with ASTM A653, and have a
<br />minimum galvanized coating designation as specified in
<br />the plans accompanying this report.
<br />3.3 Foam Core Sandwich Panels:
<br />The Metals USA Building Products laminated foam roof
<br />sandwich panels used as components of patio covers
<br />only must be designed and installed in accordance with
<br />ESR-2229.
<br />3.4 Fasteners:
<br />Fasteners used in the installation of the structures must be
<br />as specified in the plans accompanying this report.
<br />4.0 DESIGN AND INSTALLATION
<br />The design and installation of the patio covers, carports
<br />and commercial structures described in this report must be
<br />in accordance with this report and with the accompanying
<br />plans, dated February 24, 2014 (for the 2012 IBC/IRC),
<br />December 5, 2011 (for the 2009 IBC/IRC), and May 30,
<br />2010 (for the 2006 IBC/IRC), as referenced in Tables 1,2
<br />and 3, respectively.
<br />5.0 CONDITIONS OF USE
<br />The Metals Building Products, freestanding and attached
<br />patio covers, carports, and commercial structures
<br />described in this report comply with, or are suitable
<br />alternatives to what is specified in, those codes listed in
<br />Section 1.0 of this report, subject to the following
<br />conditions:
<br />5.1 Construction of patio covers, carports and commercial
<br />structures must comply with this report and the plans
<br />accompanying this report dated February 24, 2014
<br />(for the 2012 IBC/IRC), December 5, 2011 (for the
<br />2009 IBC/IRC), or May 30, 2010 for the 2006
<br />IBC/IRC), as referenced in Tables 1, 2 and 3,
<br />respectively. Where there is a conflict between this
<br />report and the plans, this report governs.
<br />5.2 Patio covers are limited to use as structures regulated
<br />under Appendix I of the IBC and Appendix H of the
<br />IRC.
<br />5.3 Carports and commercial structures are limited to use
<br />as structures regulated by the applicable chapters
<br />and sections of the IBC, including IBC Section 406.
<br />5.4 Any unit built in an area with a flat roof snow load
<br />greater than 30 psf in Seismic Design Category A, B,
<br />C, D, DO, Dl, 02, E, or F, and not complying with
<br />Exception 1 of IBC Section 1613.1, is outside the
<br />scope of this report.
<br />*Revised March 2014
<br />ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed
<br />as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as
<br />to any jinding or other matter in this report, or as to any product covered by the report.
<br />Copyright © 2014 Page 1 of 3