Laserfiche WebLink
Plannlng & Bulldlng Agency <br />Bulldlng Safety Dlvlslon <br />20 Clvlc Cantor Plaza <br />P.O. Box 1988 (M.19) <br />Santa Ana, CA92702 <br />(7r4) 647-5800 <br />www.aanta-ana.org <br />sol-01 cBC 20't5 <br />Solar Photovoltalc (PV) Checklist for Dotached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certification section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11" x 17" size. lf answerinq NO to anv of the questions. plan check shall be required. <br />Project Address: <br />Contraclor Company l,lame: <br />Contractor License Number: <br />YES NO, Ptr <br />2. Eltr <br />Etr <br />6 Etr <br />? Ftr <br />I Eltr <br />9 Ptr <br />ro.6 E <br />V\ Lu wq <br />4 <br />5 <br />tr <br />u <br />E <br />P <br />Are the following applicable to the proposed proJect? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.1 1 of the Califomia Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV anay be flush mountsd to the existing roof so that the plane of th€ <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a spac€ of 2'minimum to 10'maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will the anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16'lag screws be installed with a minimum of 2-112 inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans stamped and signed by a Califomia <br />licens6d professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />Dale: 1r "tA " 2o 14 <br />I certlfy under penalty of psrrury undor tho laws of the Stato of C a that the above is true: <br />Print Name: 4 ^)Aq-n lwavA ct Signature <br />-5Phone Number: <br />Email Address:t/\l^,,,y\<d Gf , t o'vn <br />Rev: 8/29119 <br />tz+ee rvqi re (7- rvtn/ne <br />RESIDENTIAL <br />PHOTOVOLTAIC <br />GHECKLIST <br />it'l 7r- zc,