My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10181208_2031 S. ARTESIA - Plan
PBA
>
Building
>
Plans
>
A
>
Artesia St
>
2031 S Artesia St
>
10181208_2031 S. ARTESIA - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/19/2022 12:02:12 AM
Creation date
10/25/2020 5:22:24 PM
Metadata
Fields
Template:
Plan
Permit Number
10181208
Full Address
2031 S Artesia St
Fully Linked
True
Document Relationships
10181208 - Permit
(Permit - Plan)
Path:
\Building\Permits\A\Artesia St\2031 S Artesia St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PLAQUES AND LABELING <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />MODULE MAKE SUNPOWER <br />MODULE MODEL SPR-327-NE-WHT-D <br />MAX POWER-POINT CURRENT ('Mp)5.98 A <br />MAX POWER-POINT VOLTAGE (VMp)54.7 v <br />OPEN-CIRCUIT VOLTAGE (Voc)64.9 v <br />SHORT-CIRCUIT CURRENT ('sc)6.46 A <br />MAX SERIES FUSE (OCPD) 20 A <br />MAXIMUM POWER (PMAD 327 w <br />MAX VOLTAGE (TYP 600VDc)600 v <br />VOC TEMP COEFF (mV/°C[Z]or %/°CED -176.6 <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />NOTES FOR ALL DRAWINGS: <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODE® REFERENCES <br />SHOWN AS (NEC)00000 <br />INVERTER RATINGS (Guide Section 4) <br />INVERTER MAKE FRONIUS <br />INVERTER MODEL IG Plus Advanced 3.8-1 UNI (240V) <br />MAX DC VOLT RATING 600 v <br />MAX POWER @ 40°C 3800 w <br />NOMINAL AC VOLTAGE 211 -264 v <br />MAX AC CURRENT 15.8 A <br />MAX OCPD RATING 20 A <br />SIGNS-SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECT <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT 11.96 A <br />RATED MPP VOLTAGE 328 v <br />MAX SYSTEM VOLTAGE 436 v <br />MAX CIRCUIT CURRENT 16.15 A <br />WARNING: ELECTRICAL SHOCK <br />HAZARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />SIGN FOR INVERTER OCPD AND <br />AC DISCONNECT (IF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />AC OUTPUT CURRENT 15.8 A <br />Label for DC conduit and j-boxes <br />CAUTION: DC SOLAR CIRCUIT <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): <br />NOMINAL AC VOLTAGE 240 v <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />NOTES FOR INVERTER CIRCUITS (Guide Section 8 and 9): <br />..2 jo; <br />36 07 <br />m the <br />1.) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT TEMP -4 °C <br />1) IF UTILITY REQUIRES A VISIBLE-BREAKSWITCH, DOES THIS SWITCH MEET THE <br />REQUIREMENT? YESZI Nom N/AU NOT <br />of any <br />2.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMPERATURE 44 °C <br />2.) 2005 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED <br />47°C IN THE UNITED STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9 <br />CURRENT-CARRYING CONDUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST 0.5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47°C OR LESS (ALL OF UNITED STATES), <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES Q] NO[] N/Acl <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690.53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING. (See Guide Section 9) <br />5) TOTAL OF 1 INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL <br />a) 12 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUSE. <br />b) 10 AWG, 90°C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH Isc OF 9.6 AMPS OR LESS WHEN PROTECTED BY A 15-AMP OR SMALLER <br />FUSE. <br />SUPPLY BREAKERS COMPLY WITH 120% BUSBAR EXCEPTION IN 690.64(B)(2)(a)? <br />YES Gl NO 1-1 <br />Contractor Name,Notes for One-Line Standard Electrical <br />Address and Phone: <br />1. RATED MPP CURRENT: 5.98A( Imp) x 2 (Strings) = 11.96A <br />2. RATED MPP VOLTAGE: 54.7V(Vmp) x 6 (Modules) = 328.2V (328V) <br />3. MAX SYSTEM VOLTAGE: <br />64.9V(Voc) x 1.12(Temp Correction) x 6 (Modules) = 436.1V (436V) <br />SUNPRO SOLAR Diagram for Single-Phase PV Systems <br />34859 FREDRICK ST. 101 Site Name: Luis Reyes <br />WILDOMAR, CA. 92595 Site Address: 2031 S. Artesia St., Santa Ana 92704 <br />951-678-7733 <br />System AC Size: 3.45kWac <br />SIZE FSCM NO DWG NO REVDrawn By: Bob Kornrnann El.2 <br />Checked By:%4 I - *ink SCALE NTS Date: 4/21/14 SHEET <br />4. MAX CIRCUIT CURRENT: 6.46A(Isc) x 2 (Strings) x 125% = 16.15A
The URL can be used to link to this page
Your browser does not support the video tag.