<br />\t;*2379 Plan Submittal Criteria for COMMERCIAL projects, MULTIFAMILY;2*&4 RESIDENTIAL projects and RESIDENTIAL TRACT developments
<br />INSTRUCTIONS: Fill in the project/business address and provide a brief description of the scope of work and type of business
<br />operation that will take place. Answer questions 1 through 8, read and initial item 9, then complete and sign the certification section. If
<br />you answer "YES" to any pm·t of question 1 through 8, submit the type of plan indicated in italies to the OCFA (see www. ocfa.org for
<br />submittal information and locations). In some cases: other plan types not indicated herein may also be necessary depending on specific,
<br />'conditions or operations. Ifyou need help completing this form or have questions regarding requirements for review. please contact the
<br />OCFA at 714-573-6108 or visit us at 1 Fire Authority Road in Irvine for assistance.
<br />Address (street nu.mber & name, suite, city): / r Ao)#AAA,v PL LQ_ Sm#L fU . 01.
<br />Project Scope/Business Descriptiont -* ri :1·=4/4-uik. 9 8- (27' E-/echdc- CAo«p:y· 6*4£2-
<br />YES NO
<br />1. Construction of a new building, a new story, or increase the footprint of an existing building? Changes toroadways, curbs, or drive aisles? Addition, relocation, or modification of fire hydrants or fences/gates?Fire
<br />Master Plan (PR 145)
<br />2. Installation/modification/repair of underground piping, backflow preventers, or fire department connectionsserving private fire hydranUsprinkler/standpipe systems? Underground Plan. (PR470, PR475)
<br />3. Drinking/dining/recreation/religious functions or other gatherings in a room >750 sq.ft. or >49 people?44.- Healthcare or outpatient services for >5 people who may be unable to immediately evacuate without
<br />assistance? 24-hour care or supervision? Incarceration or restraint? Hotel, apartment, or residential facility with
<br />- 3+ units and 4+ stories, or podium/wrap construction? Congregate housing/dormitories with 4+ stories and 17+
<br />people? High-rise structure (55+ feet to highest occupied floor level)?Architectural Plan (PR200-PR285)
<br />4. 131 Installation/modification of locks delaying or preventing occupants from leaving a space or requiring use of a»0 card, button, or similar action to open a door in the direction of exit travel?Architectural, Sprinkler, and/or Alarm
<br />Plan depending on :the occupancy and type of device installed (PR200-PR280, PR420-PR425, PR 500-PR520)
<br />5. (industrial/commercial refrigeration systems; compressed gasses, tanks for cryogenic or flammable/combustible
<br />Installation/modification/use of spray booths; dust collection; dry cleaning; industrial ovens/drying equipment;
<br />liquids, vapor recovery; smoke control; battery back-up/charging systems (>50 gal. electrolyte, >1,000 lb. lithium
<br />ion), welding/brazing/soldering, open flame torches, cutting/grinding; or other similar operations?Special
<br />Equipment Plan (PR315, PR340-PR382)
<br />6. OP Storage/use/research with flammable/combustible liquids or other chemicals? Motor vehicle/aircraft
<br />maintenance/repair? Cabinetry/woodworking/finishing facility? Chem C/ass & f/oor plan (full architectural plan
<br />if H occupancy); Special Equipment Plans may be necessary. (PR315-PR360, PR232-PR240)
<br />7., Clfe Storage or merchandizing areas in excess of 500 sq, ft. where items are located higher than 12' (6' for high-»'' hazard commodities, plastic, rubber, foam, etc.)?High-piled Storage Plan (PR330)
<br />8. [ fyi Cooking under a Type I commercial hood; installation or modification of a fire extinguishing system located in a46.-1 commercial cooking hood? Hood &Duct Extinguishing System, not just the hood mechanical plan. (PR335)
<br />Initial that you have read and understand the following statement:
<br />9. *Sprinkler/Alarm Requirements: Consult California Building and Fire Codes and local ordinances (see the local
<br />ordinance for buildings constfucted prior to Jan. 1, 1946) to determine sprinkler or alarm system requirements; if a
<br />system is required, plans shall be submitted to OCFA. Existing buildings undergoing remodel must be evaluated by a
<br />licensed contractor to determine if modification is needed, if so, the licensed contractor shall submit plans for approval
<br />prior to making modifications. (Initial here:FA . )
<br />Building Department: Ifal! of the questions have been answered accurately as "NO" and the project does not otherwise require OCFA
<br />review of spfinkler or alarm plans-*, then you may accept this signed form as a written release that OCFA review is not required.
<br />Should you still require that the applicant have plans approved by the OCFA please initial here or attach an OCFA referral
<br />form and have the applicant submit the form along with the appropriate plans and fees for OCFA review.
<br />I certify under-Benalty of perjury under the laws of the State of Califor,·liahat tl9 above is true:Print name: -1--Foln 45% <4:xylc>b.Signature:U U11/
<br />Phone Number:89% 589 - 9037 Date: A %)2419
<br />1 /2-28-2013 ese
|