My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
820 N Euclid Street - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Euclid St
>
820 N Euclid St
>
820 N Euclid Street - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 10:58:25 AM
Creation date
10/16/2025 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20186581
Full Address
820 N Euclid St
Street Number
820
Street Direction
N
Street Name
Euclid
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
101
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
© 2024 IronRidge, Inc. XR Flush Mount System Certification - Rev B - 3 <br /> <br /> <br />28357 Industrial Blvd. <br />Hayward, CA 94545 <br />1-800-227-9523 <br />IronRidge.com <br /> <br />8. Allowable span length in the charts may be multiplied by a factor of 1.08 if the rails are continuous over a minimum <br />of three spans. This factor may not be used in determining maximum cantilever length. <br /> <br />9. No splices are allowed in the rail cantilever. For each XR splice type install per the following requirements: <br />a) XR Bonded Splice cannot be installed in the center 1/3 of interior spans, or the outer 2/3 of end spans. <br />b) BOSS Splice can be installed at any location within a span. <br /> <br />10. Shaded cells of the span tables indicate conditions in which UFO Mid Clamp connection capacity is exceeded if <br />such conditions are encountered contact techsupport@ironridge.com. <br /> <br />11. Systems using CAMO module clamps shall be installed with the following guidance: <br />a) For single module installations (orphan modules), CAMO clamps shall not be installed in regions that <br />experience ground snow loads in exceedance of what is listed in the following table. Such scenarios are <br />shown by asterisks in the applicable span tables. <br /> <br />b) CAMO will function within a module’s design load ratings. Be sure the specific module being used with <br />CAMO meets the dimensional requirements shown in the figure below and that the module selected is <br />suitable for the environmental conditions of a particular project. <br /> <br /> <br />Figure 1: CAMO Module Frame Dimensional Requirements <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />Maximum Ground Snow load for Orphan Modules using CAMO per ASCE 7-16 <br />Module Area 21.7 ft2 23.5 ft2 28.0 ft2 30.5 ft2 <br />Ground Snow 60 psf 55 psf 40 psf 40 psf
The URL can be used to link to this page
Your browser does not support the video tag.