WARNING <br />ELECTRIC SHOCK HAZARD <br />TERMINALS ON BOTH THE LINE AND LOAD SIDE <br />MAY BE ENERGIZED IN THE OPEN POSITION <br />WARNING <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE <br />THIS OVERCURRENT DEVICE <br />WARNING: <br />DIRECT CURRENT PHOTOVOLTAIC POWER <br />SOURCE DISCONNECT <br />DC Operating Parameters:A <br />Max. System Voltage:419V <br />Maximum Current:11.13A <br />Rated Vmp:321 V <br />Rated Imp:8.42 A <br />DIRECT CURRENT PHOTOVOLTAIC POWER <br />SOURCE DISCONNECT <br />At each junction box, combiner box, disconnect, and <br />device where energized, ungrounded circuits may be <br />exposed during service: (NEC 690.35(F)) <br />WARNING <br />ELECTRIC SHOCK HAZARD. THE DC <br />CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM <br />ARE UNGROUNDED AND MAY BE ENERGIZED. <br />This Service is fed by multiple power sources. <br />Disconnect all sources prior to servicing this <br />equipment. <br />Generation system AC <br />Disconnect is Interconnect Breaker. <br />OPERATING VOLTAGE = 240 V <br />MAXIMUM CURRENT = 16 A <br /> No. C58724 4 <br />\* Exp. 3-31-15 // <br />41€GM23:;>' <br />DC Operating Parameters: <br />Max. System Voltage: <br />Maximum Current: <br />Rated Vmp: <br />Rated Imp: <br />W. 411 X <br />251 V <br />11.13A <br />193 V <br />8.42 A <br />Signage: <br />Signage material shall be reflective, weather-resistant <br />material suitable for the environment. <br />All signage shall fall within the format: <br />White Lettering on a Red Background <br />Minimum 3/8" Letter Height <br />All Letters Shall be Capitalized <br />Arial or Similar Font, Non-Bold <br />On Main Service Disconnect: <br />Sign may be placed within the main service disconnect. <br />The sign shall be placed on the outside cover if the main <br />service disconnect is operable with the service panel <br />closed. <br />"CAUTION: SOLAR ELECTRIC SYSTEM <br />Notes: <br />1. Utility is 120V/240V 1 03\N. O 0 <br />2. PV System is Utility Interactive. 0 - <br />3. Inverter is fully compliant with NEC 690.61 R zg! <br />concerning Lack of Interactive System Power.0- N <br />4. All PV system components shall be listed by a 8 <6 <br />recognized testing agency.m " <br />5. Wiring material shall be suitable for the sun exposure <br />and wet locations. <br />6.Where the terminal of the disconnecting means may 4 <br />be energized in the open position, a warning sign shall <br />be mounted on or adjacent to the disconnecting means.(1) <br />The sign shall be clearly legible and have the following 06 >CD <br />words or equivalent: "WARNING - ELECTRIC SHOCK <br />HAZARD, DO NOT TOUCH TERMINALS. TERMINALS E I a u <br />ON BOTH THE LINE AND LOAD SIDES MAY BE (0 0 04 <br />ENERGIZED IN THE OPEN POSITION."C cou <br />7. Signs shall be posted adjacent to each PV disconnect .2 (D (Dand inverter to indicate, "Photovoltaic System". <br />8. All PV modules and associated equipment and wiring <br />material shall be protected from any physical damage.c (1) Uj <1 <br />9. In one- and two-family dwelling, live parts in PV .59 CE cr <br />source circuits and PV output circuits over 150 Volts to L CD 4- <br />ground shall not be accessible to other than qualified (1) c (\1 C <br />persons while energized.li c o <br />10. All field installed junction, pull and outlet boxes 1-<C\'U: <br />located behind modules or panels shall be accessible Rev Date <br />directly or by displacement of a module(s) or panel(s) <br />secured by removable fasteners. <br />11. Pressure terminals tightened to the recommended <br />torque specification <br />12. Crimp-on terminals listed and installed with listed <br />crimping tools by the same manufacturer. <br />13. User accessible fuses in "touch-safe" holders or <br />capable of being changed without touching live <br />contacts. 2 <br />www. Loyd W Martin .com <br />Solar Structures Engineering <br />#2014-723 Structural Only <br />CONNECTED" <br />On DC Conduit, Raceways, Enclosures, Cable <br />Assemblies, DC Combiners and Junction Boxes: <br />Markings shall be placed every 10 feet on all interior <br />and exterior DC conduits, raceways, enclosures, and <br />cable assemblies, at turns above and / or below <br />penetrations, all DC combiners, and junction boxes. <br />"WARNING: PHOTOVOLTAIC POWER SOURCE" <br />|REI No. C 58724 6,1(*322!.'Til)«OF-CAL\F¢*Drawn By: Sunny <br />Date: 05/12/2014 <br />Sheet: <br />PV-5 <br />NOTES AND <br />SIGNAGE <br />V <br />V <br />--