MODULE DETAIL <br />Yingli Energy YL250P-29b <br />SOLAR MODULE <br />Enphase M215-60-2LL-S2x-ZC <br />MICRO-INVERTER AT - <br />EACH MODULE, ATTACHED <br />WITH ZEP HARDWARE <br />#6 BARE CU GROUND(GROUNDING MODULE- - <br />&INVERTER) <br />MICRO-INVERTER CONNECTION <br />ENPHASE ENGAGE TRUNK CABLE <br />NOTE: ALL PLACARDS SHALL HAVE A RED BACKGROUND, <br />MINIMUM 3/8" LETTER HEIGHTS, ALL CAPITAL LETTERS, <br />ARIAL OR SIMILAR FONT, NON BOLD, REFLECTIVE <br />WEATHER MATERIAL SUITABLE FOR THE ENVIRONMENT. <br />Inverter Ratings (Guide Section 4) <br />Inverter Make/Model Enphase M215-60-2LL <br />Max DC Volt Rating <br />Max Power @ 40°C <br />Nominal AC Voltage <br />Max AC Current <br />Max OCPD Rating <br />Max Number of Panels/Circuit <br />NOTES FOR INVERTER CIRCUITS (Guide Section <br />1.) IF UTILITY REQUIRES A VISIBLE-BREAK SWIT( <br />SWITCH MEET THE REQUIREMENTS? <br />YES NO X NA <br />2.) IF GENERATION METER REQUIRED, DOES TH <br />SOCKET MEET THE REQUIREMENTS? <br />YES NO X NA <br />3.) SIZE PHOTOVOLTAIC POWER SOURCE (DC) C <br />BASED ON MAX CURRENT ON SIGN OR OCPD <br />RATING AT DISCONNECT. <br />4.) SIZE INVERTER OUTPUT (AC) CONDUCTORS, <br />TO INVERTER OCPD AMPERE RATING (See Guide <br />5.) TOTAL OF 2_ INVERTER OCPD(s). ONE FOI <br />PV CIRCUIT. DOES TOTAL SUPPLY BREAKERS C( <br />WITH 120% BUSBAR EXCEPTION X YES NO <br />Signs (See Guide Section 7 <br />Sign for inverter OCPD and AC Disconnect: <br />Solar PV System AC Point of <br />Connection <br />AC Output Current 22.500000 Amps <br />Nominal AC Volt.240 Volts <br />THIS PANEL FED BY MULTIPLE SOURCES <br />(UTILITY AND SOLAR) <br />-Six-zc <br />45 Volts <br />215 Watts <br />240 Volts <br />0.9 Amps <br />20 Amps <br />17 <br />8 and 9): <br />DH, DOES THIS <br />IS METER <br />ONDUCTORS <br />ACCORDING <br />' Section 9) <br />R EACH <br />OMPLY <br />If Main Disconnect is <br />rated less than the <br />Busbar rating: <br />"Caution-Solar <br />Connection. Do Not <br />increase size of main <br />disconnect" <br />O Conduit and Conductor Schedile <br />Tag Description Wire Gauge #of Conductors Conduit Type Conduit Size <br />1 Enphase engage cable - THWN-2 12 AWG 4 N/A - Free Air N/A - Free Air <br />1 Bare Copper Ground (EGC/GEC)6 AWG 1 N/A - Free Air N/A - Free Air <br />2 THWN-2 10 AWG 6 EMT 0'-1" <br />2 THWN-2 - Ground 8 AWG 1 EMT 0'-1" <br />3 THWN-2 8 AWG 3 PVC 0'-1" <br />3 THWN-2 - Ground 8 AWG 1 PVC 0'-1" <br />PV Module Ratings @ STC (Guide Section 5) <br />Model Make/Model Yingli Energy YL250P-29b <br />Max Power-Point Current (Imp)8.11 Amps <br />Max Power-Point Voltage (Vmp)30.2 Volts <br />Open-Circuit Voltage (Voc)37.8 Volts <br />Short-Circuit Current (Isc)8.63 Amps <br />Max Series Fuse (OCPD) 15 Amps <br />Nominal Maximum Power at STC (Pmax)240 Watts <br />Maximum System Voltage 1000(IEC)/600(UL) <br />Voc Temperature Coefficient -0.33 %/°C <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Section 6 and 8 and Appendix D): <br />1.) Lowest expected ambient temperature based on ASHRAE minimum mean extreme dry <br />bulb temperature for ASHRAE location most similar to installation location: -1.5°C <br />2.) Highest continuous ambient temperature based on ASHRAE highest month 2% dry bulb <br />temperature for ASHRAE location most similar to installation location: 37°C <br />3.) 2005 ASHRAE fundamentals 2% design temperatures do not exceed 47°C in the United <br />States (Palm Springs, CA is 44.1°C). For less than 9 current-carrying conductors in <br />roof-mounted sunlit conduit at least 0.5" above roof and using the outdoor design <br />temperature of 47°C or less (all of United States). <br />a.) 12 AWG, 90°C conductors are generally acceptable for modules with Isc of 7.68 Amps <br />or less when protected by a 12-Amp or smaller fuse. <br />b.) 10 AWG, 90°C conductors are generally acceptable for modules with Isc of 9.6 Amps <br />or less when protected by a 15-Amp or smaller fuse. <br />'Al""Whh3>t;fe- of €74/27//,A e .0 -......0.0.0-0 <br />:97 ,®; .10 & (3.-'•®®.EL <br />PV CIRCUIT 1: 13 MODULES/PARALLEL .N. - <br />-y- t....Rf:Er 'ry- E <br />- 7-6 <br />POINT OF DELIVERY 8 0©.8 9737€/ cky..4,AND INTERCONNECTION cy (2 0 n*8 00 <br />@ T <br />PV CIRCUIT 2: 7 MODULES/PARALLEL 40/PO <br />le424 <br />i <br />i-\ <br />30// <br />COMBINER <br />PANEL <br />125AJ240V <br />VISIBLE/LOCKABLE <br />'OPEN BLADE' A/C <br />DISCONNECT <br />915A <br />EXISTING <br />240V/200A <br />LOAD-CENTER <br />\Ely <br />NOTE: NEUTRAL CONDUCTOR(S) OMITTED FOR CLARITY <br />ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR. <br />WARNING LABELS WITH WHITE LETTERS/RED BACKGROUND WILL BE <br />PROVIDED ON A/C DISCONNECT <br />)JUNCTION BOX 1 <br />WITH IRREVERSIBLE <br />GROUND SPLICE <br />2 /3\ <br />El.0 " \19 <br />Siemens <br /># LNF222R <br />60A/240V ( <br />FUSED <br />NEMA3 <br />SOLAR BREAKER <br />SHALL BE PLACED AT <br />THE EXTREME <br />OPPOSITE SIDE OF <br />THE UTILITY SUPPLY <br />El.0/ <br />. <br />.