Laserfiche WebLink
900,11 <br />mounting <br />systems <br />Alpha technical data <br />Application <br />Roofing material <br />Roof slope <br />Building height <br />PV modules <br />Module layout <br />Module orientation <br />Pitched roof - on-roof <br />Suitable for most roof types <br />Up to 600 1 <br />Up to 20 m · 66 ft 1 <br />Framed, unframed <br />In rows or columns <br />Landscape, portrait Splice technology <br />Size of modute array Any size 2 <br />Position of the module amy No special requirements <br />Possible height allowance Up to 38 mm · 1.5 in <br />Distance between roof Up tolm· 6.6ftl <br />attachments ,-\1 <br />Standards International Building Code IBC 2009 36-0 ra <br />Ca/(fomia Building Code CBC 2010 <br />ASCE/SEI 7-10 <br />Aluminum Design Manual 2010 Telescoping end-piece <br />ANSI/AIS[ 360-05 <br />Aa 318-08 <br />Supporting profiles Extruded Aluminum (EN AW 6063 T66) <br />Hooks, small parts Stainless steel (V2A) <br />Color Natural (silver) <br />Warranty 10 years 3 <br />a Base rail <br />b Telescoping end-piece <br />c Module end clamp <br />d Roof hook <br />e Sptice <br />1 Different maximum values may apply, and are dependent on site, building, choice of roof attachments and <br />modules. Using the Alpha calculation tool you can have the correct values for your project calculated quickly <br />and easily. <br />2 Due to the,mal expansion of the material, we recommend a slight gap in the array every 12 m (39.4 ft.) <br />3 Please see the Mounting Systems, Inc. warranty document for details. <br />1 <br />Alpha <br />lEi <br />7