Laserfiche WebLink
IGALVANIZED 21/2.x 12'x 7 GAGE THICK <br /> STEEL STRAP W/4-5/8'0 LAGS - APPROVED CAP <br />1+14 <br />12• <br />4-x4'31/2' <br />4 --45©f 4'x BE, <br />POST -7 - 5-8D NAILS, <br />EACH END <br />- fl / 4'x BEAM <br /> - 4'x41° KNEEBRACE <br />2.-- 74 <br />1 12-1/2' 0 x 5- LONG LAGS SCREWS 1"xe KNEE <br />_/ NEACH END BRACE <br />- - -H- 1(SEE DETAIL'ED <br />42 4'x4' POST MINIMUM <br />DETAIL "B"DETAIL "B" ALTERNATE <br />STANDOFF 1 7» <br />ISTAND-OFF <br />APOST <br />/ IBASE -- <br />-1' STAND-OFF <br />r€91 <br />r 41'x BEAM <br />12' ..1 <br />ANCHOR <br />BOLT +1 <br />31/20 <br />EMBEDI A rANCHORS IN k-·---._ IGALVANIZEDCONCRETE | -5 9 12'x1217 GAGE+ IT W/6-5/8» 0 LAGS <br />1 - <br />t.- 4.x POST <br />GRADEJ <br />DETAIL "C" <br />DETAIL "D" <br />NOTES: <br />ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BE NEW <br />AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK. <br />ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING <br />CODE CURRENTLY IN EFFECT. <br />CONCRETE SLAB TO BE MINIMUM 31/2" THICK. <br />POSTS SHALL BE MINIMUM 4"x4". <br />BOTTOM OF POSTS SHALL BE ONE INCH (1") ABOVE SLAB. <br />ROOF SHEATING SHALL BE: <br />a. 1/2" PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32/16, T&G <br />STRUCTURAL I, WITH 10 d AT 6" O/C AT SUPPORTED ENDS, ANC)12" O/C ALONG <br />INTERMEDIATE FRAMING MEMBERS, OR <br />b. 1" BOARD SPAN 32"; 2" SOLID T&G SPAN 8'-0"; 2"xy SELF-SPACED SPAN 6'-0". <br />ROOFING SHALL BE MIN. CLASS "C" ROOF COVERING (CBC TABLE 1505.1) OF: <br />a. WOOD SHAKES: 4/12 PITCH <br />b. WOOD SHINGLES: 3/12 PITCH <br />c. BUILT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4"/FT.) <br />d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />MAXIMUM HEIGHT FOR A PATIO COVER IS TWELVE FEET. <br />PATIO COVER SHALL BE USED ONLY FOR RECREATIONAL OUTDOOR LIVING <br />PURPOSE AND NOTAS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br />OF THE LONGER WALLAND ONE ADDITIONAL WALL IS EQUAL TO AT LEAST SIXTY- <br />FIVE PERCENT OF THE AREA BELOW A MINIMUM OF 6'-8" OF EACH WALL, <br />MEASURED FROM THE FLOOR. <br />. OPENINGS MAY BE ENCLOSED WITH INSECT SCREENING OR PLASTIC THAT IS <br />READILY REMOVABLE, TRANSLUCENT, OR TRANSPARENT PLASTIC NOT MORE THAN <br />1/8 INCH IN THICKNESS. <br />. EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br />INTO AN AREA OF AN UNENCLOSED PATIO COVER. <br />. PATIO COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />--4- <br />- 4°x4" KNEE BRACE <br />7 2-1/2· 0 *5' LONG LAG SCREWS <br />TT <br />F 4¤x POST <br />DETAIL "E" <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF PATIO COVER: <br />PRINT NAME SIGNATURE DATE <br />291 1 lt« f h»_-9 294.2 <br />rev: 07/19/2011 Page 2 of 2 <br />a