10181447_1408 N. MAIN - Plan
PBA
>
Building
>
Plans
>
M
>
Main St
>
1408 N Main St
>
10181447_1408 N. MAIN - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2021 11:51:22 AM
Creation date
10/25/2020 5:22:40 PM
Metadata
Fields
Template:
Plan
Permit Number
10181447
Full Address
1408 N Main St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
15
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DESIGN CRITERIA: <br />CODE:2013 CBC <br />WIND:BASIC WIND SPEED: 110 MPH (3 SEC. GUST), EXPOSURE: C, RISK CAT.: II <br />SEE WIND CALCULATIONS FOR DESIGN WIND PRESSURES <br />LOADS:DL: 10 PSF, LL: 0 PSF, SL: 0 PSF <br />STRUCTU RAL TECHNOLOGY CONSULTANTS <br />7827 CONVOY COURT, SUITE 406, SAN DIEGO, CA 92111 PHONE NO.: 858.278.2400 FAX NO.:858.278.2424 <br />PROJECT: WSS - SHOE STYLE SELECTION #36, 1408 N. MAIN STREET, SANTA ANA, CA SHEET:1 OF 1 <br />PROJ. NO,: 1120-190 DESIGNER: VH DATE:06-03-14 <br />CLIENT:SAN PEDRO ELECTRIC SIGN COMPANY STRUCIT. TYPE: BLADE SIGN QUANTITY: 1 <br />EE <br />CONTRACTOR'S RESPONSIBILITY: <br />THE CONTRACTOR SHALL FIELD VERIFY THAT EXISTING AND PROPOSED SITE CONDITIONS ARE CONSISTENT WITH THESE DRAWINGS PRIOR <br />TO THE START OF ANY WORK. NOTIFY ENGINEER OF RECORD IMMEDIATELY IF SITE CONDITIONS VARY FROM THESE DRAWINGS. <br />CONTRACTOR (INSTALLER) IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND JOBSITE SAFETY. <br />SCOPE OF WORK: <br />THE SCOPE OF STC'S DESIGN IS LIMITED TO MOUNTING PLATE, ANCHORAGE, SUPPORT ARM, AND ArrACHMENT OF SIGN CABINET TO <br />SUPPORT ARM. ALL OTHER rTEMS ARE EXCLUDED, INCLUDING, BUT NOT LIMITED TO SIGN CABINET FRAMING, AND EXISTING WALL <br />STRUCTURE AND ITS CAPACITIES, ANY MODIFICATIONS TO STC'S DESIGN SHALL BE REVIEWED AND APPROVED BY A LICENSED ENGINEER. <br />STRUCTURAL TECHNOLOGY CONSULTANTS (STC) DESIGN IS BASED ON DRAWINGS AND DIMENSIONS PROVIDED TO STC BY OTHERS. THE <br />MANUFACTURER AND INSTALLER SHALL VERIFY ALL FINAL DIMENSIONS AS SHOWN ON THE ENGINEERING DRAWINGS AND THE SHOP <br />DRAWINGS, AND SHALL BE RESPONSIBLE TO ENSURE THE FIT OF ALL COMPONENTS. <br />GENERAL NOTES: <br />1. ALUMINUM: GRADE 6061-T6 (Fty=35 KSI MIN.). <br />2. ROLLED STEEL / PLATE STEEL: ASTM A36 (Fy=36 KSI MIN.). <br />3. NUTS AND WASHERS SHALL BE USED WITH ALL FASTENERS AND SHALL BE COMPATIBLE WITH FASTENER SIZES, MATERIAL TYPES, AND <br />HOLE SIZES, IN ACCORDANCE WITH AISC SPECIFICATIONS, UNLESS NOTED OTHERWISE. <br />4. THE MATERIAL/COATING TYPE USED FOR THE CORROSION RESISTANCE OF FASTENERS SHALL BE BASED ON EXPOSURE CONDITIONS <br />AND THE RECOMMENDATIONS SET FORTH BY AISC, IN ACCORDANCE WITH COMMON INDUSTRY PRACTICE. NO GUARANTEE TO <br />PREVENT CORROSION THROUGHOUT THE LIFE OF A STRUCTURE IS IMPLIED. FASTENERS SHALL BE MONITORED PERIODICALLY FOR <br />SIGNS OF DETERIORATION. <br />5. LAG SCREWS: ASTM A307 (Fu=58 KSI MIN.). INSTALLATION PER 2005 NDS. <br />6. THREADED RODS: ASTM A307 (Fu=58 KSI MIN.). <br />7. ALUMINUM WELDING: ALL WELDING SHALL BE PERFORMED BY AWS QUALIFIED WELDERS USING AWS APPROVED SYSTEMS AND <br />PROCEDURES, IN ACCORDANCE WITH AWS Dl.2/Dl.2M: 2008 STRUCTURAL WELDING CODE - ALUMINUM. <br />8. ALL FABRICATION SHALL OCCUR IN THE SHOP OF AN APPROVED FABRICATOR, AS DESIGNATED BY THE LOCAL BUILDING DEPARTMENT. <br />9. PROVIDE A PROTECTIVE COATING TO MINIMIZE CORROSION FOR ALL STEEL MEMBERS EXPOSED TO WEATHER, MOISTURE, OR SOIL. <br />10. PROVIDE ISOLATION OF DISSIMILAR MATERIALS INCLUDING A PROTECTIVE COATING FOR ALL ALUMINUM TO BE IN CONTACT WITH <br />STEEL OR CONCRETE. (EXAMPLE: NEOPRENE BARRIER, PLASTIC WASHER, ZINC COATING, OR SIMILAR.) <br />11. IT IS THE RESPONSIBILITY OF THE OWNER OR OWNER'S REPRESENTATIVE TO MONITOR STRUCTURAL ELEMENTS AND FASTENERS FOR <br />DAMAGE, CORROSION, OR DETERIORATION. <br />6/4/2014 9:04:40 AM <br />4'-0" <br />15'-0" <br />__-1 <br />MAX. <br />LD <br />A <br />(2)-CONTINUOUS 1 <br />STL. L 2"x2"x3/16" <br />STRINGER BEHIND <br />WALL TO SPAN (16" MAX.) 1_j \ N <br />OVER TWO STUDS ALUM RT 2"x2")24"Al, <br />W/ (2)-1/4" WOOD 1 <br />SCREWS W/ 1-1/2" MIN. PEN.- EXISTING WOOD <br />INTO STUD STUD WALL m ELEVATION <br />@ 16" O.C.| SCALE: ITS. <br />P. <br />.-1 TYPICAL SADDLE )ETAIL <br />j| SCALE: ITS. <br />.XJi.hv- <br />ALUM. PL 5/8"x8"x8" <br />W/ (4)-3/8"0 THRU-BOLTS <br /> A,SE'3.E DETAIL <br /></A°4% ap. 06/30/2014*No.075980 =111m <br />»f OF CAL\0>' <br />1 <br />r, <br />-b <br />3 <br />9 <br />8" <br />TYP. <br />6" <br />11 /3/16 v \ <br />TYP. 1 [) 1 -/1/16 <br />3/lb ' <br />20 6 <br />STRUCTURAL TECHNOLOGY CON5UL I AN I b UK lib Urrlltle UK ABIC 13 Ir,ALL INI I Dc Ic/ruly/1{kc f un <br />I rl' ....r./.1 W. .VI·,1 ..1 .ii.-·.w wi -Il-li••••-•- -V.