DC DISCONNECT WARNING AC DISCONNECT WARNING SERVICE PANEL <br />PHOTOVOLTAIC SYSTEM <br />DC DISCONNECT <br />OPERATING VOLTAGE XXX VDC <br />OPERATING CURRENT XXX ADC <br />MAX SYSTEM VOLTAGE XXX VDC <br />SHORT CIRCUIT CURRENT XXX ADC <br />A WARNING A <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF <br />THIS PHOTOVOLTAIC SYSTEM <br />ARE UNGROUNDED AND <br />MAY BE ENERGIZED <br />PERNEC 690.14(C)(2. 8103*F). 69063 0*000 <br />per NEC 690.53 <br />operating voltage, operating current, max system voltage, <br />short circuit current and maximum output current of <br />the charge controller if one is installed. <br />PLACE ON: Main Solar Disconnect <br />PHOTOVOLTAIC SYSTEM <br />- ./.5.m <br />DISCONNECT - <br />PHOTOVOLTAIC SYSTEM <br />AC DISCONNECT <br />OPERATING CURRENT XXX AMPS <br />OPERATING VOLTAGE 240 VOLTS <br />A WARNING A <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />PER NEC 690.141/12). 8917(4). 8954 <br />O..1 <br />per NEC 690.54 <br />operating voltage, operating current <br />PLACE ON: Inverter Breaker Panel <br />if sum of breakers exceeds panels rating <br />CAUTION <br />POWER TO THIS BUILDING IS SUPPLIED FROM <br />THE FOLLOWING SOURCES WITH <br />DISCONNECTS LOCATED AS SHOWN <br />m1 <br />1/1 %I <br />MI <br />SOLAR ARRAY E <br />1 <br />r MAIN SERVICE <br />PANEL <br />--1 AC DISCONNECT | <br />INVERTER I <br />PV METER <br />1 <br />1 <br />1 <br />04-b .In 04 650 <br />must show drawing of the property and <br />equipment layout. per NEC 690.56 <br />Sample House <br />1 WARNING A <br />DUAL POWER SUPPLY <br />SOURCES: UTILITY GRID AND <br />PV SOLAR ELECTRIC SYSTEM <br />p.11,bc=n 0121, <br />"Dual Power Supply" label <br />NEC 690.64,705.12(4) <br />Point of Connection <br />1 WARNING A <br />ELECTRIC SHOCK HAZARD <br />DO NOT TOUCH TERMINALS <br />TERMINALS ON BOTH THE LINE AND <br />LOAD SIDES MAY BE ENERGIZED <br />IN THE OPEN POSITION <br />m-=03-100 <br />"Do not touch terminals" label <br />NEC 690.17(4) <br />Switch or Circuit Breakers <br />LABELING <br />Description Date Rev.L S' <br />ORIGINAL 4/25/14 A COR <br />ARB <br />& N <br />ttion@ <br />Ul to! <br />W,ltll <br />Ice . <br />CONTRACTOR: <br />Stearns Solar <br />16381 Nosoni Rd.. - <br />Apple Valley, CA 92307 <br />760-514-1537 Aim <br />LlC# 988327 <br />"PV System Disconnect" label 1 WARNING A HOME OWNER: <br />NEC 690.14(C)(2)Paul Ziesmer <br />Required Disconnect Markings INVERTER OUTPUT CONNECTION CAUTION: SOLAR ELECTRIC THIS ELECTRIC SYSTEM 2202 Freeman St. <br />DO NOT RELOCATE ,IS ALSO SERVED BY A Santa Ana, CA 92706 <br />THIS OVERCURRECT DEVICE SYSTEM CONNECTED -1 PHOTOVOLTAIC SYSTEM i 714-560-0600DC LABELS .....m 01212 - <br />- "Inverter output connection" label i ./.1./.' <br />NEC 705.12(7)PROJECTADDRESS: <br />PLACE ON: 1. DC Junction Boxes Point of Connection 2202 Freeman St. <br />2. DC Combiner Boxes <br />Santa Ana, CA 92706 <br />1 WARNING A OTHER <br />ELECTRIC SHOCK HAZARD <br />THE DC CONDUCTORS OF THIS <br />PHOTOVOLTAIC SYSTEM ARE <br />UNGROUNDED AND <br />MAY BE ENERGIZED <br />P•Utal:cor 01,04 <br />"Electric Shock Hazard" label. NEC 690.35(F) <br />Ungrounded PV Systems <br />PLACE ON: 1. DC Junction Boxes <br />2. DC Combiner Boxes <br />PLACE ON: All DC Source Markings and System <br />Output Conductors Raceways <br />CAUTION SOLAR CIRCUIT <br />pvhbob. com 03-329 <br />"Caution Solar Circuit" label NEC 690.4(F), 690.31(E)(4) <br />place on conduit every 10 feet IFC 605.11.1.1 & IFC 605.11.1.2 <br />'MUST BE REFLECTIVE IF INDOORS OR IN ATTIC <br />PLACE ON: Next to Inverter Interconnection <br />Breaker, Load Center, & Service Panel <br />PV SOLAR BREAKER <br />DO NOT RELOCATE <br />THIS OVERCURRENT <br />_ DEVICE <br />PLACE ON: Near GFI Reset <br />A WARNING A <br />ELECTRIC SHOCK HAZARD <br />IF GROUND FAULT IS INDICATED <br />ALL NORMALLY GROUNDED <br />CONDUCTORS MAY BE <br />UNGROUNDED AND ENERGIZED <br />PHOTOVOLTAIC <br />& POWER j <br />SOURCE <br />10, <br />"Ground Fault Indicated" label <br />NEC 690.5(C) <br />Ground Fault Protection <br />"PV Power Source" label. NEC 690.31(E)(3) <br />DC - PV Source Conductors <br />SIGNAGE REQUIREMENTS:PV-4S <br />RED BACKGROUND. WHITE LETTERING. C'WARNING" - 3/8' LETTERS). ALL CAPITAL LETTERS. ARIAL OR SIMILAR FONT. WEATHER- RESISTANT MATERIAL, UL 969.STRING INVERTER
The URL can be used to link to this page
Your browser does not support the video tag.
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).