My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
709 W Jonquil Rd - Plan
PBA
>
Building
>
ProjectDox
>
J
>
Jonquil Rd
>
709 W Jonquil Rd
>
709 W Jonquil Rd - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/13/2025 10:28:12 AM
Creation date
10/29/2025 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
20187087
Full Address
709 W Jonquil Rd
Street Number
709
Street Direction
W
Street Name
Jonquil
Street Suffix
Rd
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
37
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
MSP <br />UM <br />ACD <br />DCD <br />ACD PW3 <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI D <br />17" X 11" <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-7 <br /> M <br />I <br />C <br />H <br />A <br />E <br />L <br /> <br />Y <br />I <br />70 <br />9 <br /> <br />W <br /> <br />J <br />O <br />N <br />Q <br />U <br />I <br />L <br /> <br />R <br />D <br />, <br /> <br />S <br />A <br />N <br />T <br />A <br />AN <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />, <br /> <br />U <br />S <br />A <br />REVDATEDESCRIPTION <br />NEW09/17/2025ORIGINAL PLAN <br />CONTRACTOR <br />SOLAR OPTIMUM INC. <br />ADDRESS: 1833 S VICTORY BLVD, <br />GLENDALE, CA 91201, USA <br />TEL:(818)804-3122 <br />LIC#: 972228, C-10 <br />AP <br />N <br />: <br /> <br /> <br />00 <br />2 <br />- <br />0 <br />3 <br />7 <br />- <br />1 <br />4 <br />ARPIAR TARVERDI <br />PLACARDS <br />CAUTION: <br />POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE <br />FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN <br />THE PROJECT SHALL COMPLY WITH THE <br />CURRENT VERSION OF THE DEPARTMENT <br />ELECTRICAL POWER SOURCE DISCONNECT <br />PLACARDING SYSTEM <br />ENERGY STORAGE SYSTEM <br />1.MATERIAL USED FOR THE SIGNAGE SHALL BE REFLECTIVE,WEATHER RESISTANT <br />AND SUITABLE FOR THE ENVIRONMENT. <br />2.ALL SIGNAGE SHALL HAVE ALL CAPITAL LETTERS WITH MINIMUM 3/8" LETTER <br />HEIGHT,WHITE ON RED BACKGROUND. <br />3.MAIN SERVICE DISCONNECT MARKING SHALL BE PLACED ADJACENT TO <br />MAIN SERVICE DISCONNECT IN A LOCATION CLEARLY VISIBLE FROM THE LOCATION <br />WHERE THE LEVER IS OPERATED. <br />4.MARKING IS REQUIRED ON ALL INTERIOR AND EXTERIOR DC CONDUIT, <br />RACEWAYS,ENCLOSURES,CABLE ASSEMBLIES,AND JUNCTION BOXES TO ALERT THE <br />FIRE SERVICE TO AVOID CUTTING THEM.MARKING SHALL BE PLACED EVERY 10',AT <br />TURNS AND ABOVE AND/OR BELOW PENETRATIONS, <br />AND AT ALL DC COMBINER AND JUNCTION BOXES. <br />5.DO NOT US SCREWS FOR SIGNAGE ATTACHMENT. USE ONLY APPROVED ADHESIVE. <br />SIGNAGE NOTES <br />SOLAR PV SYSTEM EQUIPPED <br />WITH RAPID SHUTDOWN <br />SOLAR ELECTRIC <br />PV PANELS <br />TURN RAPID SHUTDOWN <br />SWITCH TO THE "OFF" <br />POSITION TO SHUT DOWN <br />PV SYSTEM AND REDUCE <br />SHOCK HAZARD IN THE <br />ARRAY. <br />690.56(C)(1)(a) <br />SIGNAGE LOCATIONS: <br />MAIN SERVICE PANEL <br />6" X 3 1/2" <br />ELECTRICAL SHOCK HAZARD <br />WARNING <br />TERMINALS ON LINE AND LOAD <br />SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />690.13 (B) <br />SIGNAGE LOCATIONS: <br />MAIN SERVICE PANEL <br />PV COMBINER BOX <br />PV SYSTEM AC DISCONNECT <br />INDOOR/OUTDOOR SUB PANEL <br />WARNING <br />TURN OFF PHOTOVOLTAIC AC <br />DISCONNECT PRIOR TO <br />WORKING INSIDE PANEL <br />110.27 (C) <br />SIGNAGE LOCATIONS: <br />MAIN SERVICE PANEL <br />PV COMBINER BOX <br />PV SYSTEM AC DISCONNECT <br />INDOOR/OUTDOOR SUB PANEL <br />PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFEED <br />CAUTION <br />690.13 (F), 705.12(B)(3-4) & 690.59 <br />SIGNAGE LOCATIONS: <br />PV COMBINER BOX <br />INDOOR/OUTDOOR SUB PANEL <br />WARNING! <br />NEC 705.12 (B)(2)(c) <br />SIGNAGE LOCATIONS: <br />MAIN SERVICE PANEL <br />INDOOR/OUTDOOR SUB PANEL <br />POWER SOURCE OUTPUT <br />CONNECTION. DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE. <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />NEC 690.56(C)(3) <br />SIGNAGE LOCATIONS: <br />MAIN SERVICE PANEL <br />WARNING <br />LABEL LOCATION: <br />BATTERY SUBPANEL <br />PANELS THAT COMPLY WITH <br />CEC 705.12(D)(2)(3)(C) <br />THIS EQUIPMENT FED BY MULTIPLE <br />SOURCES. TOTAL RATING OF ALL <br />OVERCURRENT DEVICES,EXCLUDING MAIN <br />SUPPLY OVERCURRENT DEVICE,SHALL NOT <br />EXCEED AMPACITY OF BUSBAR. <br />WARNING <br />LABEL LOCATIONS: <br />BATTERIES <br />INVERTER <br />ELECTRIC SHOCK HAZARD <br />IF A GROUND FAULT IS <br />INDICATED, NORMALLY <br />GROUNDED CONDUCTORS <br />MAY BE UNGROUNDED AND <br />ENERGIZED <br />!! <br />! <br />! <br />! <br />RAPID SHUTDOWN SWITCH <br />FOR SOLAR PV SYSTEM <br />TRI POWER GRID, ESS AND PV <br />WARNING <br />705.12(B)3-4 & 690.59 <br />SIGNAGE LOCATIONS: <br />MAIN SERVICE PANEL <br />PV COMBINER BOX <br />! <br />CAUTION <br />TRI POWER SOURCE SECOND <br />SOURCE IS AC BATTERY <br />THIRD SOURCE IS PHOTOVOLTAIC <br />SYSTEM <br />LABEL LOCATION: <br />SERVICE DISCONNECT <br />SUBPANELS <br />! <br />PHOTOVOLTAIC DC DISCONNECT <br />RATED MAXIMUM POWER-POINT CURRENT: <br />RATED MAXIMUM POWER-POINT VOLTAGE: <br />MAXIMUM SYSTEM VOLTAGE: <br />MAXIMUM SHORT CIRCUIT CURRENT: <br />ADC <br />VDC <br />VDC <br />ADC17.24 <br />13.07 <br />199.86 <br />251.60 <br />LABEL LOCATION: <br />INVERTER(S), DC DISCONNECT(S) <br />MAXIMUM AC OUTPUT CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 48.00 AMPS <br /> 240 VAC <br />PV/BATTERY FUSED DISCONNECT <br />690.54 <br />SIGNAGE LOCATIONS: <br />PV SYSTEM AC DISCONNECT <br />SIGNAGE LOCATIONS: <br />BATTERY <br />BATTERY 1 OF 1 <br />WARNING <br />LABEL LOCATIONS: <br />MAIN PANEL <br />PANELS THAT COMPLY WITH <br />CEC 705.12(D)(2)(3)(B) <br />INVERTER OUTPUT <br />CONNECTION DO NOT <br />RELOCATE THIS <br />OVERCURRENT DEVICE <br />! <br />MAIN SERVICE PANEL <br />UTILITY METER <br />BACKUP SWITCH <br />BUS BAR OVERLOAD PROTECTION USED TO LIMIT <br />CONTINUOUS CURRENT ON BUS BAR TO 160A. <br />THE MAXIMUM OUTPUT CURRENT FROM THIS <br />SYSTEM TOWARDS THE MAIN PANEL IS <br />CONTROLLED ELECTRONICALLY. <br /> PCS LABEL <br />MAXIMUM CURRENT SETTING: 160A <br />DATE OF CALCULATION AND SETTING: 17/SEP/2025 <br />IDENTIFICATION OF LOADS AND SOURCES ASSOCIATED WITH THE CURRENT <br />LIMITING FEATURE: POWERWALL 3 INVERTER OUTPUT <br />"THE SETTING FOR THE PCS CURRENT LIMITING FEATURE SHALL NOT BE <br />BYPASSED" <br />LABEL LOCATIONS: MAIN SERVICE PANEL <br />2020 NEC.705.13 <br />MAXIMUM AC OUTPUT CURRENT: <br />NOMINAL OPERATING AC VOLTAGE: <br /> 48.00 AMPS <br /> 240 VAC <br />PV/BATTERY DISCONNECT <br />690.54 <br />SIGNAGE LOCATIONS: <br />PV SYSTEM AC DISCONNECT <br />LABEL LOCATION: ESS Unit (S) <br />DC DISCONNECT <br />PV/BATTERY DISCONNECT <br />PV ARRAY (TYP.) <br />PV/BATTERY FUSED <br />DISCONNET <br /> W JONQUIL RD
The URL can be used to link to this page
Your browser does not support the video tag.