Laserfiche WebLink
IGALV.ANIZED 2 "2.4 1.:t., 7 GAGE THICK <br />l S'FEEL STRAP W/4-5/8-9 LAGS - APPROVED CAP <br />1+ <br />2· <br />31/2 4'k4' <br />1 .--1 2 <br />21 t <br />POST -- / y- 5.81) N,'MLS. <br />A EACH END459x BEAM '1 /· 4·x BEAM <br />4·14· KNEE b 71RcE h l k <br />12-1,2' 0 x 5· LONG LAGS SCREWS <br />AEACH END <br />1 - 1(SEE DETAIL 'E') <br />L t-xs·KNEE <br />BRACE <br />4%(41' POST MINIMUM <br />DETAIL "B"DETAIL "B" ALTERNATE <br />STAND·OFFSTANDOFF 1'-7 -<2X mPOST <br />- 1· STAND-OFF <br />- 4·x BEAM <br />10.1 <br />:1 1 <br />- ANCHOR L r- i i ... ++1 <br />EMBEDI <br />ANCHORS IN -CONCRETE <br />\ IGALVANIZED <br /> 12•x 12·*7 GAGE <br />IT Wi·6-5/8' O LAGS <br />KI - 4% POST02 <br />-4/GRADEJ <br />DETAIL "C" <br />BOLT <br />31/2' <br />DETAIL ' <br />\»X <br />D" <br />NOTES: <br />ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BE NEW <br />AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK: <br />ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING <br />CODE CURRENTLY IN EFFECT. <br />CONCRETE SLAB TO BE MINIMUM 31/2" THICK. <br />POSTS SHALL BE MINIMUM 4"x4". <br />BOTTOM OF POSTS SHALL BE ONE INCH (l ") ABOVE ;SLAB. <br />ROOF SHEATING SHALL BE: <br />a. 1/2" PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32/16, T &G <br />STRUCTURAL I, WITH 10 d,AT 6" O/C AT SUPPORTED ENDS, AND12" O/C ALONG <br />INTERMEDIATE FRAMING MEMBERS, OR <br />b. 1" BOARD SPAN 32"; 2" SOLID TaG SPAN 8'-0", 2"x2" SELF-SPACED SPAN 6'-0" <br />ROOFING SHALL BE MIN. CLASS "C" ROOF COVERING (CBC TABLE 1505.1) OF: <br />at WOOD SHAKES: 4/12 PITCH <br />b. WOOD SHINGLES: 3/12 PITCH <br />c. BUILT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4"/FE) <br />d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />MAXIMUM HEIGHT FOR A PATIO COVER IS TWELVEFEET. <br />PATIO COVER. SHALL BE USED ONLY FOR RECREATIONAL OUTDOOR LIVING <br />PURPOSE AND NOT AS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />1. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br />OF THE LONGER WALL AND ONE ADDITIONAL WALL IS EQUAL TO AT LEAST SIXTY- <br />FIVE PERCENT OF THE AREA BELOW A MINIMUM OF 6'-8" OF EACH WALL, <br />MEASURED FROM THE FLOOR. <br />OPENINGS MAY BE ENCLOSED WITH INSECT SCREENING OR PLASTIC THAT IS <br />READILY REMOVABLE, TRANSLUCENL OR TRANSPARENT PLASTIC NOT MORE THAN <br />1/8 INCH IN THICKNESS. <br />. EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br />INTO AN AREA OF AN UNENCLOSED PATIO COVER. <br />. PATIO COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />- 4·x4· KNEE BRACE <br />l <br />F 2-1/2· 0 *5· LONG LAG SCREWS <br />-0-0- <br />F 4'x POST <br />DETAIL "E" <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF P5*COVER <br />abs€ ?ERA rw <br />PAINT NAME <br />1 055 PG#(el <br />rev: 07/19/201 1 <br />6-11- <br />O/ SIGNA)(dRE DAT <br />/4 <br />E <br />'ll <br />Page 2 012