Laserfiche WebLink
JGALY.AMIZED 2 2.. 12·, 7 GAGE THICK <br />1 STEEL STRAP W/4-5/8·0 LAGS - APPROVED CAP <br />31/2'1 | I <br />*it 434· POST MINIMUM <br />0 .1 9>4 -r;24 2--LD1- <br />459 2 4*x BEAM 1 <br />/ :42 BEAM <br />-•-0 4·*4· KNEE 30 <br />/ BRACE 2 /A <br />12-112· 0 x 5·LONG LAGS,SCREWS <br />4 EACH'END <br />1(SEE DEIAll'E') ./1 <br />L i ·16' KNEE <br />BRACE: <br />DETAIL "B"DETAIL "'B" ALTERNATE <br />STANDOFF 1¤ < <br />-1:'STAND-OFFISTAND·OFF <br />4 posT 0:118*SE - <br />r 4'x BEAM <br />1 12' <br />, <br />I A 1'11 1/14-1 1 --ANCHOR I + +1 <br />$ F Fl#rf,/ 34 f -T'-+ +3126-- + f fEMBEDI .00111/lifl'*f)- ':+f-- ANCHORS IN - · - 1 <br />CONCRETE 1. .Ii.. .: 11110 g*N'CE+ TW/6-518' 9 LAGS <br />w-·,· 7 -i Y·J_ _Ll .[. ...' .0.·1'· -.' ]!11' --4'x pOST <br />GRADE \L/- -·/ <br />DETAIL "C" <br />DETAIL "D" <br />NOTES: <br />ALL MATERIALS: LUMBER, HARDWARE, PLYWOOD, ROOFING, ETC. SHALL BE NEW <br />AND BEAR MANUFACTURER'S OR CERTIFIED AGENCY'S GRADE MARK. <br />ALL CONSTRUCTION SHALL CONFORM TO THE CALIFORNIA BUILDING <br />CODE CURRENTLY IN EFFECT <br />CONCRETE SLAB TO BE MINIMUM 31/2" THICK. <br />POSTS SHALL BE MINIMUM 4"x4' <br />BOTTOM OF POSTS SHALL BE ON:E INCH (1') ABOVE SLAB. <br />ROOF SHEATING SHALL BE: <br />a. 12' PLYWOOD, CDX, 5 PLY EXTERIOR GLUE, WITH INDEX 32(16, T&G <br />STRUCTURAL L WITH 10 d AT 6" O/C AT SUPPORTED ENDS, AND12" O/C ALONG <br />INTERMEDIATE FRAMING MEMBERS, OR <br />b. 1" BOARD SPAN 32": 2" SOLID T&G SPAN:8'-0"; 2"x2" SELF-SPACED SPAN 640" <br />ROOFING SHALL BE MIN. CLASS "C" ROOF COVERING (CBC TABLE 1505.1) OF: <br />a. WOOD SHAKES: 4/12 PITCH <br />b. WOOD SHINGLES: 3/12 PITCH <br />c. BUILT-UP ROOF SLOPE TO DRAIN (MINIMUM 1/4'/FT ) <br />d. CLAY AND CONCRETE ROOF TILES INSTALLED IN ACCORDANCE WITH <br />MANUFACTURER'S INSTRUCTIONS. <br />MAXIMUM HEIGHT FOR A PATIO COVER IS TWELVE FEET. <br />PATIO COVER SHALL BE USED ONLY FOR RECREATIONAL OUTDOOR LIVING <br />PURPOSE AND NOTAS CARPORT, GARAGE, STORAGE ROOM OR HABITABLE ROOM. <br />1. ENCLOSURE WALLS MAY HAVE ANY CONFIGURATION, PROVIDED THE OPEN AREA <br />OF THE LONGER WALLAND ONE ADDITIONAL WALL IS EQUAL TO AT LEAST SIXTY- <br />FIVE PERCENT OF THE AREA BELOW A MINIMUM OF 6'-8" OF EACH WALL, <br />MEASURED FROM THE FLOOR. <br />. OPENINGS MAY BE ENCLOSED WITH INSECT SCREENING OR PLASTIC THAT IS <br />READILY REMOVABLE, TRANSLUCENT, OR TRANSPARENT PLASTIC NOT MORE THAN <br />1/8 INCH IN THICKNESS. <br />. EMERGENCY EGRESS OR RESCUE WINDOWS FROM SLEEPING ROOMS MAY OPEN <br />INTO AN AREA OF AN UNENCLOSED PATIO COVER. <br />. PATIO COVER MUST BE AT LEAST 5 FEET FROM PROPERTY LINES. <br />4·x4· KNEE BRACE <br />F 2- 172' 0 *5· LONG LAG SCREWS <br />TT <br />E- 4'x POST <br />141 <br />DETAIL "E" <br />b <br />PERSON RESPONSIBLE FOR DESIGN AND CONSTRUCTION OF PATIO COVER: <br />\ fo.3 8 s G eurL€R=6 -l L-(4/TA 7 41/0/ SIZMATURE6 1, Uy <br />PRINT NAME DATE <br />6>92 292,22¥6-4-21 ? M <br />rev: 07/19/2011 Page 2 01 2