My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10181747_3357 S. BRISTOL - Plan
PBA
>
Building
>
Plans
>
B
>
Bristol St
>
3357 S Bristol St
>
10181747_3357 S. BRISTOL - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2023 12:08:00 AM
Creation date
10/25/2020 5:22:47 PM
Metadata
Fields
Template:
Plan
Permit Number
10181747
Full Address
3357 S Bristol St
Fully Linked
True
Document Relationships
10181747 - Permit
(Permit - Plan)
Path:
\Building\Permits\B\Bristol St\3357 S Bristol St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
UL48 41.1.1 (ej Conditions of use for components required to complete wtrtng* <br />cIm iaecognized Componenr LED. Class 2 Illumination SystemModules Suitable for wet or dry location; Faotory Wired. <br />(Narna of oomponent mfg.) <br />2. Recognized Component" Class 2 Power Supply in 24 ga sheet metal <br />enclosure. Power supplv lactory installed in enclosure. Secure enclosure to <br />wall swface with four (4; wall board fasteners <br />3. Type PLC cable* irated for use wilhout conduit in damp or dly location. <br />Connect power supply output leads with:insulated compression wirecannectors to matching color of free oonductom in secdon letter Bundle <br />neatly and secure to wall with piastic cable ties witEn 12" of conduit and <br />enclosure and at 6' intervals. <br />C.Im <br />k <br />§ <br />4. Drill r dia holes thwough cement block facia, perpendicular to wall <br />at locations shown on full size installation pattern. Secure 1/2",unning <br />thread to metal letter back. Remove paint from metal at point of conne©0on <br />to condul Double lock=nut, ,p,renal tight Insert 12" rning thread <br />through holes in wail. Apply silacone sealant around conduit and hole in <br />cement block before litting the letter back flush with wall surface. <br />5. Thread groundjng bushing onto 1/2* running thread ©ondwit, <br />Attach No. 14 bonding jumper to each bushing (6>and to one Power <br />suppgy endosure Bond enclosures 10 branch circuil equipment ground. <br />6. Channel letter subassembly sign body suitable for wet localion. <br />One 1/4- drain hole in low points of each letter. Attaoh metal letter back to <br />building lacia with 1/4" concrete fasteners at predrilled Iczations in letter <br />back. <br />*3* <br />tal7. No. 14 MC Cable between power supply enclosures and disconnect. <br />Secure to wall with cable lies, Malhin twelve (121 inches of te,mination at <br />enclosure and at no Oess than al six fool (6) intervals <br />8. Safety Switch / Single Pole / Dry gocation. Firmly secure in piaoe with <br />wallboard fastners <br />Branch circuit conductors of suitable capacity and approvd type to section <br />sign by others, (120 V / 20 AMP / 792 VA) <br />tdO. <br />*66) COPY OF MANUFACTURERS CONDmONS OF USE FOR EACH OOMPONENT <br />ANACNED AND INCLUDED AS PART OF INSTALLA71O9 INSTRUCm©HS. <br />Appendi©GG 321 <br />10
The URL can be used to link to this page
Your browser does not support the video tag.