Laserfiche WebLink
EngDrwg: 2021r5RGT_Eng <br />23656 - Hernandez Jr ADU & ADU Qty: 1 Truss: A1 <br />Customer: P&P Morales <br />Truss Mfr. Contact: Vice Ahumada <br />SID:0003668807 <br />TID:280459 <br />Date:07 / 18 / 25 <br />Page:1 of 2 <br />NOTICE A copy of this design shall be furnished to the erection contractor. The design of this individual truss is based on design criteria and requirements supplied by <br />the Truss Manufacturer and relies upon the accuracy and completeness of the information set forth by the Building Designer. A seal on this drawing indicates <br />acceptance of professional engineering responsibility solely for the truss component design shown. See the cover page and the “Important Information & General <br />Notes” page for additional information. All connector plates shall be manufactured by Simpson Strong-Tie Company, Inc in accordance with ESR-2762. All connector <br />plates are 20 gauge, unless the specified plate size is followed by a “-18” which indicates an 18 gauge plate, or “S# 18”, which indicates a high tension 18 gauge plate. <br />Component Solutions <br />Truss Studio V <br />2024.5.1.5 <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> 3x8 <br />2.5x4 <br />5x14 3x4 =3x4 =5x14 <br />2.5x4 <br />3x8 <br />3x4 =4x4 =5x14-18 4x4 =3x4 = <br />148#48#61#83# <br />693#255# <br />86# <br />255# <br />86# <br />255# <br />86# <br />255# <br />86# <br />255# <br />86# <br />255# <br />86# <br />255# <br />86# <br />693# <br />83#61#48#148# <br />2-0-0 2-0-0 <br />3-14 3-14 <br />2- <br />0 <br />- <br />4 <br />2- <br />3 <br />- <br />1 <br />3 <br />2- <br />9 <br />- <br />8 <br />1 <br />4-2-15 <br />4-2-15 2 <br />3-8-12 <br />7-11-11 3 <br />4-11-8 <br />12-11-3 4 <br />5-6-3 <br />18-5-5 5 <br />4-11-8 <br />23-4-13 6 <br />3-8-12 <br />27-1-9 7 <br />4-2-15 <br />31-4-8 8 <br />1 <br />7-5-0 <br />7-5-0 <br />9 <br />2-9-1 <br />10-2-1 <br />10 <br />5-6-3 <br />15-8-4 <br />11 <br />5-6-3 <br />21-2-7 <br />12 <br />2-9-1 <br />23-11-8 <br />13 <br />7-5-0 <br />31-4-8 <br />8 <br />31-4-8 <br />3-Ply <br /> 3/12 -3/12 <br />Truss Weight = 442.6 lb <br />Code/Design: CBC-2022/TPI-2014 <br />PSF Live Dead Dur Factors <br />TC 20.0 17.0 Live Wind Snow <br />BC 0.0 7.0 Lum 1.25 1.60 N/A <br />Total 44.0 Plt 1.25 1.60 N/A <br />Spacing: 2-00-00 o.c. Plies: 3 <br />Repetitive Member Increase: Yes <br />Green Lumber: No Wet Service: No <br />Fab Tolerance: 20% Creep (Kcr) = 2.0 <br />OH Soffit Load: 2.0 psf <br />-----------Snow Load Specs---------- <br />ASCE7-16 Ground Snow(Pg) = N/A <br />Risk Cat: II Terrain Cat: C <br />Roof Exposure: Sheltered <br />Thermal Condition: All Others(1.0) <br />Unobstructed Slippery Roof: No <br />Low-Slope Minimums(Pfmin): No <br />Unbalanced Snow Loads: No <br />Rain Surcharge: No Ice Dam Chk: No <br />----------Wind Load Specs---------- <br />ASCE7-16 Wind Speed(V) = 130 mph <br />Risk Cat: II Exposure Cat: C <br />Bldg Dims: L = 58.8 ft B = 39.0 ft <br />M.R.H(h)= 15.0ft Kzt = 1.0 Ke = 1.00 <br />Bldg Enclosure: Enclosed <br />Wind DL(psf): TC = 10.2 BC = 4.2 <br />End Vertical Exposed: L = Yes R = Yes <br />Wind Uplift Reporting: ASCE7 MWFRS <br />C&C End Zone: 3-10-12 <br />-------Additional Design Checks------ <br />10 psf Non-Concurrent BCLL: Yes <br />20 psf BC Limited Storage: Yes <br />200 lb BC Accessible Ceiling: No <br />300 lb TC Maintenance Load: No <br />2000 lb TC Safe Load: No <br />Unbalanced TCLL: Yes <br />Material Summary <br />TC 2x4 DFL #2 <br /> 2x4 DFL #1B 3-6 <br />BC 2x4 DFL #1B <br />Webs 2x4 DFL Std/Stud <br /> <br />Member Forces Summary <br />Max CSI in TC PANEL 3 - 4 0.97 <br />Max CSI in BC PANEL 10 - 11 0.81 <br />Max CSI in Web 3 - 10 0.48 <br /> <br />...Mem... Ten Comp .CSI. <br />TC OH- 1 42 0 0.11 <br /> 1- 2 961 12172 0.45 <br /> 2- 3 1038 12726 0.56 <br /> 3- 4 1317 15769 0.97 <br /> 4- 5 1568 18605 0.61 <br /> 5- 6 1317 15769 0.97 <br /> 6- 7 1038 12726 0.56 <br /> 7- 8 961 12172 0.45 <br /> 8-OH 42 0 0.11 <br />BC 1- 9 11732 875 0.63 <br /> 8-13 11732 875 0.63 <br /> 9-10 12407 936 0.59 <br /> 10-11 18337 1589 0.81 <br /> 11-12 18337 1589 0.81 <br /> 12-13 12407 936 0.59 <br />Web 2- 9 749 135 0.09 <br /> 3- 9 163 132 0.01 <br /> 3-10 3885 347 0.48 <br /> 4-10 416 3032 0.18 <br /> 4-11 1153 557 0.14 <br /> 5-11 1153 557 0.14 <br /> 5-12 416 3032 0.18 <br /> 6-12 3885 347 0.48 <br /> 6-13 163 132 0.01 <br /> 7-13 749 135 0.09 <br /> Reaction Summary <br /> --------------Reaction Summary(Lbs)---------------- <br /> Jnt --X-Loc- React -Up- --Width- -Reqd -Mat PSI <br /> 1 01-12 3768 287 03-08 01-08 DFL 677 <br /> 8 31-02-12 3768 287 03-08 01-08 DFL 677 <br /> Max Horiz = -27 / +27 at Joint 1 <br />Loads Summary <br />User-defined unbalanced Top Chord Live Loads (TCLL) occurring at 15-08-04 <br />are based on 1.00 full and 0.00 reduced load factors. <br />See Loadcase Report for load combinations and additional details. <br />Loads based on maximum and minimum reactions from tie-in spans <br /> Mbr Max Min Location Dir Description <br /> Transfer loads: <br /> TC 693 -122 8-02-04 Vert 1-A_0005 @ 135 Deg <br /> TC 255 -54 10-00-12 Vert 1-A_0010 @ 90 Deg <br /> TC 255 -54 12-00-12 Vert 1-A_0011 @ 90 Deg <br /> TC 255 -54 14-00-12 Vert 1-A_0012 @ 90 Deg <br /> TC 255 -54 15-08-04 Vert 1-A_0031 @ 90 Deg <br /> TC 255 -54 17-03-12 Vert 1-A_0012 @ 90 Deg <br /> TC 255 -54 19-03-12 Vert 1-A_0011 @ 90 Deg <br /> TC 255 -54 21-03-12 Vert 1-A_0010 @ 90 Deg <br /> TC 693 -122 23-02-04 Vert 1-A_0005 @ 45 Deg <br /> BC 148 8 2-00-12 Vert 1-A_0006 @ 90 Deg <br /> BC 48 25 4-00-12 Vert 1-A_0007 @ 90 Deg <br /> BC 61 24 6-00-12 Vert 1-A_0008 @ 90 Deg <br /> BC 83 20 8-00-12 Vert 1-A_0009 @ 90 Deg <br /> BC 86 20 10-00-12 Vert 1-A_0010 @ 90 Deg <br /> BC 86 20 12-00-12 Vert 1-A_0011 @ 90 Deg <br /> BC 86 20 14-00-12 Vert 1-A_0012 @ 90 Deg <br /> BC 86 20 15-08-04 Vert 1-A_0031 @ 90 Deg <br /> BC 86 20 17-03-12 Vert 1-A_0012 @ 90 Deg <br /> BC 86 20 19-03-12 Vert 1-A_0011 @ 90 Deg <br /> BC 86 20 21-03-12 Vert 1-A_0010 @ 90 Deg <br /> BC 83 20 23-03-12 Vert 1-A_0009 @ 90 Deg <br /> BC 61 24 25-03-12 Vert 1-A_0008 @ 90 Deg <br /> BC 48 25 27-03-12 Vert 1-A_0007 @ 90 Deg <br /> BC 148 8 29-03-12 Vert 1-A_0006 @ 90 Deg <br /> <br />3-PLY TRUSS Fastener Spacing <br />Fasten each ply to the adjacent ply as follows(rows staggered): <br />TC 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c.** <br />BC 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 12.0" o.c. <br />WB 2x4, 1-row(s) of 0.131" dia. x 3.0" Nails @ 9.0" o.c. <br />** Use additional fasteners of the same type (u.n.o.) within +/-12" of <br />the location(s) indicated (except where approved hangers are used with <br />fasteners that transfer the load to all plies): <br /> <br />TC:8-02-04, 3, TC:23-02-04, 3 <br /> <br />Deflection Summary <br />TrussSpan Limit Actual(in) Location <br />Vert LL L/360 L/614(-0.61) 10-11 <br />Vert DL L/120 L/552(-0.67) 11-12 <br />Vert CR L/240 L/291(-1.28) 11-12 <br />Horz LL 0.75in ( 0.10) @Jt 8 <br />Horz CR 1.25in ( 0.20) @Jt 8 <br />Ohng CR 2L/240 2L/999(-0.01) 1- 1 <br />Ohng CR 2L/240 2L/999(-0.01) 8- 8 <br />Bracing Data Summary <br />------------Bracing Data------------ <br />Chords; continuous except where shown <br />Web Bracing -- None <br /> <br />Plate offsets (X, Y): <br />(None unless indicated below) <br />Jnt3(0,-01-00), Jnt6(0,-01-00), <br />Jnt11(0,-01-00)