My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1303 N Bristol St - REV 1 - Plan
PBA
>
Building
>
ProjectDox
>
B
>
Bristol St
>
1303 N Bristol St
>
1303 N Bristol St - REV 1 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/12/2025 11:45:25 PM
Creation date
11/12/2025 5:00:03 AM
Metadata
Fields
Template:
Plan
Permit Number
20184665
20184666
30148140
40139785
40140843
101121872
101121874
101124811
Full Address
1303 N Bristol St
Street Number
1303
Street Direction
N
Street Name
Bristol
Street Suffix
St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1 WALL CANOPY KITCHEN HOOD1 DETAIL <br />N.T.S. <br />3 HOOD EXHAUST FAN / MAKE-UP AIR UNIT DETAILS <br />N.T.S. <br />2 WALL CANOPY KITCHEN HOOD2 DETAIL <br />N.T.S. <br />14' 6"NOM./14' 6.00"OD. <br />16'-6.00" OVERALL LENGTH <br />54" <br />12" <br />UTILITY <br />CABINET. <br />24 <br />X <br />1 <br />8 <br />X <br />8 <br />. <br />6 <br />2 <br />B <br />O <br />X <br />12" <br />UTILITY <br />CABINET. <br />2" <br />24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"24 7/8"12"12" <br />18" <br />24 3/4" <br />9" <br />12" <br />24" <br />49 1/2" <br />9" <br />12" <br />24" <br />49 1/2" <br />9" <br />12" <br />24" <br />49 1/2" <br />9" <br />12" <br />24" <br />LIGHTING FOR ACPSP JOB # 6950327 - HOOD #1 <br />INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT. <br />TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER <br />HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. <br />TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE <br />BLACK AND WHITE WIRE TO A 120VAC SERVICE. <br />END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM <br />J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. <br />1" LAYER OF INSULATION FACTORY <br />INSTALLED IN INTERNAL BACK STANDOFF. <br />MEETS 0 INCH REQUIREMENTS FOR <br />CLEARANCE TO COMBUSTIBLE SURFACES. <br />3" <br />§ <br />40 15/16" <br />12" <br />Ø14" <br />90 1/16"43" <br />12" <br />Ø14" <br />U.L. LISTED RECESSED ROUND LED <br />FIXTURE AND LED LIGHT. <br />1" <br />1.00" WIDE INSULATED <br />BACKSPLASH 122.00" HIGH <br />X 234.00" LONG. <br />NOTE: ADDITIONAL HANGING ANGLES PROVIDED FOR HOODS 12' AND LONGER. <br />5' 6"NOM./5' 6.00"OD. <br />54" <br />2" <br />21"21"12"12" <br />18" <br />33" <br />9" <br />12" <br />28" <br />LIGHTING FOR ACPSP JOB # 6950327 - HOOD #2 <br />INPUT: 120V AC, 1 PHASE, 50/60HZ, 3.5 WATTS PER LIGHT. <br />TO CONTROL LIGHTS WITH HOOD LIGHT SWITCH, WIRE PER <br />HOOD ELECTRICAL CONTROL PANEL SCHEMATIC. <br />TO CONTROL LIGHTS WITH BUILDING LIGHT SWITCH, WIRE <br />BLACK AND WHITE WIRE TO A 120VAC SERVICE. <br />END TO END ACPSPS REQUIRE 120VAC FIELD WIRING FROM <br />J-BOX TO J-BOX. REPLACE LIGHTS WITH LED LIGHTS ONLY. <br />1" LAYER OF INSULATION FACTORY <br />INSTALLED IN INTERNAL BACK STANDOFF. <br />MEETS 0 INCH REQUIREMENTS FOR <br />CLEARANCE TO COMBUSTIBLE SURFACES. <br />3" <br />§ <br />33"33" <br />12" <br />Ø10" <br />U.L. LISTED RECESSED ROUND LED <br />FIXTURE AND LED LIGHT. <br />1" <br />1.00" WIDE INSULATED <br />BACKSPLASH 122.00" HIGH <br />X 66.00" LONG. <br />1" LAYER OF INSULATION FACTORY <br />INSTALLED IN 3" INTERNAL STANDOFF. <br />MEETS 0 INCH REQUIREMENTS FOR <br />CLEARANCE TO COMBUSTIBLE SURFACES. <br />GREASE DRAIN <br />WITH REMOVABLE CUP. <br />SEE HOOD TABLE. <br />§EXHAUST RISER. <br />HANGING ANGLE. <br />RECESSED ROUND LED FIXTURE AND LED LIGHT, <br />3500 K WARM OUTPUT. <br />23.5% OPEN STAINLESS <br />STEEL PERFORATED PANEL. <br />ATTACHING PLATES. <br />SUPPLY RISER WITH <br />VOLUME DAMPER. <br />6" <br />2 3/4" <br />14" <br />LED. <br />18" <br />1.00" WIDE INSULATED <br />BACKSPLASH 122.00" HIGH <br />X 234.00" LONG. <br />FIELD WRAPPER 8.00" HIGH <br />(SEE HOOD OPTIONS TABLE). <br />1" LAYER OF INSULATION FACTORY INSTALLED <br />ON TOP OF HOOD. MEETS 0 INCH <br />REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE <br />SURFACES. <br />23" <br />23" <br /> LEFT AND RIGHT QUARTER END PANELS. <br />EQUIPMENT <br />BY OTHERS. <br />48.0" MAX. <br />80" <br />24" NOM. <br />54"1" <br />55" <br />*6" <br />*6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. <br />*6" CLEARANCE ABOVE HOOD <br /> REQUIRED FOR FIRE SYSTEM PIPING. <br />*24" <br />*24" CLEARANCE ABOVE HOOD <br />RECOMMENDED FOR SERVICEABILITY. <br />IT IS THE RESPONSIBILITY <br />OF THE ARCHITECT/OWNER TO <br />ENSURE THAT THE HOOD CLEARANCE <br />FROM LIMITED-COMBUSTIBLE <br />AND COMBUSTIBLE MATERIALS <br />IS IN COMPLIANCE WITH <br />LOCAL CODE REQUIREMENTS. <br />20" CAPTRATE SOLO <br />FILTER WITH HOOK. <br />1" LAYER OF INSULATION FACTORY <br />INSTALLED IN 3" INTERNAL STANDOFF. <br />MEETS 0 INCH REQUIREMENTS FOR <br />CLEARANCE TO COMBUSTIBLE SURFACES. <br />GREASE DRAIN <br />WITH REMOVABLE CUP. <br />SEE HOOD TABLE. <br />§EXHAUST RISER. <br />HANGING ANGLE. <br />RECESSED ROUND LED FIXTURE AND LED LIGHT, <br />3500 K WARM OUTPUT. <br />23.5% OPEN STAINLESS <br />STEEL PERFORATED PANEL. <br />ATTACHING PLATES. <br />SUPPLY RISER WITH <br />VOLUME DAMPER. <br />6" <br />2 3/4" <br />14" <br />LED. <br />18" <br />1.00" WIDE INSULATED <br />BACKSPLASH 122.00" HIGH <br />X 66.00" LONG. <br />FIELD WRAPPER 8.00" HIGH <br />(SEE HOOD OPTIONS TABLE). <br />1" LAYER OF INSULATION FACTORY INSTALLED <br />ON TOP OF HOOD. MEETS 0 INCH <br />REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE <br />SURFACES. <br />23" <br />23" <br /> LEFT AND RIGHT QUARTER END PANELS. <br />EQUIPMENT <br />BY OTHERS. <br />48.0" MAX. <br />80" <br />24" NOM. <br />54"1" <br />55" <br />*6" <br />*6" CLEARANCE ABOVE HOOD REQUIRED FOR FIRE SYSTEM PIPING. <br />*6" CLEARANCE ABOVE HOOD <br /> REQUIRED FOR FIRE SYSTEM PIPING. <br />*24" <br />*24" CLEARANCE ABOVE HOOD <br />RECOMMENDED FOR SERVICEABILITY. <br />IT IS THE RESPONSIBILITY <br />OF THE ARCHITECT/OWNER TO <br />ENSURE THAT THE HOOD CLEARANCE <br />FROM LIMITED-COMBUSTIBLE <br />AND COMBUSTIBLE MATERIALS <br />IS IN COMPLIANCE WITH <br />LOCAL CODE REQUIREMENTS. <br />20" CAPTRATE SOLO <br />FILTER WITH HOOK. <br />M3.1 <br />KITCHEN HOOD DETAILS <br />AND HVAC SPECS <br />Te <br />l <br />e <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />0 <br /> <br /> <br />F <br />a <br />x <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />1 <br />68 <br />0 <br />0 <br /> <br />B <br />i <br />s <br />h <br />o <br />p <br /> <br />R <br />o <br />a <br />d <br />, <br /> <br />P <br />l <br />a <br />n <br />o <br />, <br /> <br />T <br />X <br /> <br />7 <br />5 <br />0 <br />2 <br />4 <br />Date: <br />Project Number: <br />Sheet Number: <br />Drawn By: <br />Store: <br />Re <br />s <br />t <br />a <br />u <br />r <br />a <br />n <br />t <br /> <br />S <br />u <br />p <br />p <br />o <br />r <br />t <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br />RAC23003.0 <br />07.12.2024 <br />MAM & JJD <br />Sheet Title: <br />1 <br />07.01.2024 VERSION 2024-1.0 RELEASE <br />Prototype : <br />Date Issued:Bulletin Number: <br />Design Bulletin Updates: <br />Prototype Issue Date: <br />- <br />2 <br />3 <br />REVISIONS: <br />4 <br />5 <br />6 <br />7 <br />A <br />9 <br />Kitchen Issue Date: <br />10 <br />Raising Cane's <br />Restaurant #C1032 <br />1303 N. Bristol st. <br />Santa Ana, CA 92706 <br />P6E-HV Scheme B <br />09 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />R <br />E <br />V <br />I <br />S <br />I <br />O <br />N <br /> <br />- <br /> <br />B <br />U <br />L <br />L <br />E <br />T <br />I <br />N <br /> <br />1 <br />09/05/24 BLDG. SUBMITTAL <br />PERMIT SET <br />P6E-AV SCHEME B 2024-1.0 <br />07.01.2024 <br />Check By:MMM <br />07.01.2024 <br />09/27/24 PLANNING RESPONSE <br />11/01/24 HEALTH DEP. RESUBMITTAL <br />12/12/24 HEALTH DEP. RESUBMITTAL <br />1/20/25 BUILDING. RESUBMITTAL <br />2/21/25 BUILDING. RESUBMITTAL <br />05/02/2025 BID SET <br />06/25/2025 CONSTRUCTION SET <br />09/12/2025 PERMIT REVISION <br />Professional of Record: <br />19401 40TH AVE W <br />SUITE 420 <br />LYNNWOOD, WA 98036 <br />CONTACT: MARK MANGLICMOT, P.E. <br />(425) 516-7882 <br />MMANGLICMOT@PMDGINC.COM <br />09/12/25 <br />MARK MANGLICMOT, PE <br />A
The URL can be used to link to this page
Your browser does not support the video tag.