Laserfiche WebLink
1" LAYER OF INSULATION FACTORY <br />INSTALLED IN 3" INTERNAL STANDOFF. <br />MEETS 0 INCH REQUIREMENTS FOR <br />CLEARANCE TO COMBUSTIBLE SURFACES. <br />GREASE DRAIN <br />WITH REMOVABLE CUP. <br />SEE HOOD TABLE. <br />§EXHAUST RISER. <br />HANGING ANGLE. <br />RECESSED ROUND LED FIXTURE AND LED LIGHT, <br />3500 K WARM OUTPUT. <br />23.5% OPEN STAINLESS <br />STEEL PERFORATED PANEL. <br />ATTACHING PLATES. <br />SUPPLY RISER WITH <br />VOLUME DAMPER. <br />6" <br />2 3/4" <br />14" <br />LED. <br />18" <br />1.00" WIDE INSULATED <br />BACKSPLASH 122.00" HIGH <br />X 234.00" LONG. <br />FIELD WRAPPER 8.00" HIGH <br />(SEE HOOD OPTIONS TABLE). <br />1" LAYER OF INSULATION FACTORY INSTALLED <br />ON TOP OF HOOD. MEETS 0 INCH <br />REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE <br />SURFACES. <br />23" <br />23" <br /> LEFT AND RIGHT QUARTER END PANELS. <br />EQUIPMENT <br />BY OTHERS. <br />48.0" MAX. <br />80" <br />24" NOM. <br />54"1" <br />55" <br />*6" <br />*6" CLEARANCE ABOVE HOOD <br /> REQUIRED FOR FIRE SYSTEM PIPING. <br />*6" CLEARANCE ABOVE HOOD <br /> REQUIRED FOR FIRE SYSTEM PIPING. <br />*24" <br />*24" CLEARANCE ABOVE HOOD <br />RECOMMENDED FOR SERVICEABILITY. <br />IT IS THE RESPONSIBILITY <br />OF THE ARCHITECT/OWNER TO <br />ENSURE THAT THE HOOD CLEARANCE <br />FROM LIMITED-COMBUSTIBLE <br />AND COMBUSTIBLE MATERIALS <br />IS IN COMPLIANCE WITH <br />LOCAL CODE REQUIREMENTS. <br />20" CAPTRATE SOLO <br />FILTER WITH HOOK. <br />1" LAYER OF INSULATION FACTORY <br />INSTALLED IN 3" INTERNAL STANDOFF. <br />MEETS 0 INCH REQUIREMENTS FOR <br />CLEARANCE TO COMBUSTIBLE SURFACES. <br />GREASE DRAIN <br />WITH REMOVABLE CUP. <br />SEE HOOD TABLE. <br />§EXHAUST RISER. <br />HANGING ANGLE. <br />RECESSED ROUND LED FIXTURE AND LED LIGHT, <br />3500 K WARM OUTPUT. <br />23.5% OPEN STAINLESS <br />STEEL PERFORATED PANEL. <br />ATTACHING PLATES. <br />SUPPLY RISER WITH <br />VOLUME DAMPER. <br />6" <br />2 3/4" <br />14" <br />LED. <br />18" <br />1.00" WIDE INSULATED <br />BACKSPLASH 122.00" HIGH <br />X 66.00" LONG. <br />FIELD WRAPPER 8.00" HIGH <br />(SEE HOOD OPTIONS TABLE). <br />1" LAYER OF INSULATION FACTORY INSTALLED <br />ON TOP OF HOOD. MEETS 0 INCH <br />REQUIREMENTS FOR CLEARANCE TO COMBUSTIBLE <br />SURFACES. <br />23" <br />23" <br /> LEFT AND RIGHT QUARTER END PANELS. <br />EQUIPMENT <br />BY OTHERS. <br />48.0" MAX. <br />80" <br />24" NOM. <br />54"1" <br />55" <br />*6" <br />*6" CLEARANCE ABOVE HOOD <br /> REQUIRED FOR FIRE SYSTEM PIPING. <br />*6" CLEARANCE ABOVE HOOD <br /> REQUIRED FOR FIRE SYSTEM PIPING. <br />*24" <br />*24" CLEARANCE ABOVE HOOD <br />RECOMMENDED FOR SERVICEABILITY. <br />IT IS THE RESPONSIBILITY <br />OF THE ARCHITECT/OWNER TO <br />ENSURE THAT THE HOOD CLEARANCE <br />FROM LIMITED-COMBUSTIBLE <br />AND COMBUSTIBLE MATERIALS <br />IS IN COMPLIANCE WITH <br />LOCAL CODE REQUIREMENTS. <br />20" CAPTRATE SOLO <br />FILTER WITH HOOK. <br />1" <br />COMBUSTIBLE WALL <br />LENGTH <br />- STAINLESS STEEL BACKSPLASH INSULATED WITH 1" THICK <br />DUCTBOARD WITH FOIL BACKING. <br />- INSULATED BACKSPLASH REQUIRES APPLIANCES WITH <br />CLEARANCE TO COMBUSTIBLES REQUIREMENTS TO BE <br />MOUNTED A MINIMUM OF 6" OFF OF THE COMBUSTIBLE WALL. <br />-HOOD REAR INSULATION MUST BE UTILIZED WITH INSULATED. <br />BACKSPLASH, UNLESS INSULATED BACKSPLASH EXTENDS TO <br />TOP OF HOOD. <br />SLIDE TOP FLANGE BEHIND LOWER <br />REAR EDGE OF HOOD UNLESS <br />LOCAL JURISDICTION REQUIRES <br />EXTENDED BACKSPLASH <br />FLANGES LOCATED <br />AT TOP AND BOTTOM <br />HEIGHT <br />SHEET NO. <br />SCALE: <br />DWG.#: <br />DRAWN <br />DATE: <br /> BY: <br />REVISIONS <br />ww <br />w <br />. <br />c <br />a <br />p <br />t <br />i <br />v <br />e <br />a <br />i <br />r <br />e <br />. <br />c <br />o <br />m <br /> <br /> <br /> <br />AC <br />C <br />O <br />R <br />D <br />A <br />N <br />C <br />E <br />No <br />. <br /> <br />9 <br />6 <br />BU <br />I <br />L <br />T <br />NF <br />P <br />A <br />WI <br />T <br />H <br />IN <br />S <br />LI <br />D <br />TE <br />R <br />6950327 <br />MASTER DRAWING <br />Ra <br />i <br />s <br />i <br />n <br />g <br /> <br />C <br />a <br />n <br />e <br />' <br />s <br /> <br />1 <br />0 <br />3 <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Lo <br />u <br />i <br />s <br />i <br />a <br />n <br />a <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br />59 <br />0 <br />4 <br />0 <br /> <br />A <br />m <br />b <br />e <br />r <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />B <br />, <br /> <br />S <br />l <br />i <br />d <br />e <br />l <br />l <br />, <br /> <br />L <br />A <br />, <br /> <br />7 <br />0 <br />4 <br />6 <br />1 <br /> <br />P <br />H <br />O <br />N <br />E <br />: <br /> <br />( <br />9 <br />8 <br />5 <br />) <br /> <br />7 <br />8 <br />1 <br /> <br />- <br /> <br />4 <br />1 <br />0 <br />7 <br /> <br />F <br />A <br />X <br />: <br /> <br />9 <br />1 <br />9 <br />7 <br />4 <br />7 <br />5 <br />6 <br />3 <br />7 <br /> <br />E <br />M <br />A <br />I <br />L <br />: <br /> <br />r <br />e <br />g <br />2 <br />7 <br />@ <br />c <br />a <br />p <br />t <br />i <br />v <br />e <br />a <br />i <br />r <br />e <br />. <br />c <br />o <br />m <br />M3.5 <br />HOOD DRAWINGS <br />Te <br />l <br />e <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />0 <br /> <br /> <br />F <br />a <br />x <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />1 <br />68 <br />0 <br />0 <br /> <br />B <br />i <br />s <br />h <br />o <br />p <br /> <br />R <br />o <br />a <br />d <br />, <br /> <br />P <br />l <br />a <br />n <br />o <br />, <br /> <br />T <br />X <br /> <br />7 <br />5 <br />0 <br />2 <br />4 <br />Date: <br />Project Number: <br />Sheet Number: <br />Drawn By: <br />Store: <br />Re <br />s <br />t <br />a <br />u <br />r <br />a <br />n <br />t <br /> <br />S <br />u <br />p <br />p <br />o <br />r <br />t <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br />RAC23003.0 <br />07.12.2024 <br />MAM & JJD <br />Sheet Title: <br />1 <br />07.01.2024 VERSION 2024-1.0 RELEASE <br />Prototype : <br />Date Issued:Bulletin Number: <br />Design Bulletin Updates: <br />Prototype Issue Date: <br />- <br />2 <br />3 <br />REVISIONS: <br />4 <br />5 <br />6 <br />7 <br />A <br />9 <br />Kitchen Issue Date: <br />10 <br />Raising Cane's <br />Restaurant #C1032 <br />1303 N. Bristol st. <br />Santa Ana, CA 92706 <br />P6E-HV Scheme B <br />09 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />R <br />E <br />V <br />I <br />S <br />I <br />O <br />N <br /> <br />- <br /> <br />B <br />U <br />L <br />L <br />E <br />T <br />I <br />N <br /> <br />1 <br />09/05/24 BLDG. SUBMITTAL <br />PERMIT SET <br />P6E-AV SCHEME B 2024-1.0 <br />07.01.2024 <br />Check By:MMM <br />07.01.2024 <br />09/27/24 PLANNING RESPONSE <br />11/01/24 HEALTH DEP. RESUBMITTAL <br />12/12/24 HEALTH DEP. RESUBMITTAL <br />1/20/25 BUILDING. RESUBMITTAL <br />2/21/25 BUILDING. RESUBMITTAL <br />05/02/2025 BID SET <br />06/25/2025 CONSTRUCTION SET <br />09/12/2025 PERMIT REVISION <br />Professional of Record: <br />19401 40TH AVE W <br />SUITE 420 <br />LYNNWOOD, WA 98036 <br />CONTACT: MARK MANGLICMOT, P.E. <br />(425) 516-7882 <br />MMANGLICMOT@PMDGINC.COM <br />09/12/25 <br />MARK MANGLICMOT, PE <br />A