1 <br />2 <br />SC-311110MA <br />PCU-CAS-TANK <br />UTILITY CABINET LEFT <br />PCU CONDITIONED TOP MOUNT UC <br />UTILITY CABINET LEFT <br />HOOD # 1 <br />NO SWITCHES <br />1 LIGHT <br />1 FAN <br />2 OTHER <br />SMART CONTROLS THERMOSTATIC CONTROL W/ <br />RELAY ON/OFF WITH SUPPLY <br />PCU-1 <br />MAU-1 <br />EXHAUST <br />SUPPLY <br />3 <br />3 <br />7.500 <br />2.000 <br />208 <br />208 <br />22.3 <br />6.1 <br />NO TAG PACKAGE #LOCATION <br />SWITCHES <br />LOCATION QUANTITY <br />OPTION <br />FANS CONTROLLED <br />FAN TAG TYPE ΙΈ HP VOLT FLA <br />Field Connection Antennas <br />Wired OR Paddle <br />Field Connection to Router <br />OR Ethernet switch <br />Connection for Modbus <br />Factory wired OR Field Wired <br />Terminal Blocks for wired connection <br />Cellular Module <br />Compute module <br />DESCRIPTION OF OPERATION: <br />6950327 <br />Raising Cane's 1032 <br />SC-311110MA <br />7/2/2025 <br />INSTALL <br />ECP #1-1 <br />3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room <br />temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. <br />BREAKER PANEL TO PRIMARY CONTROL PANEL <br />Responsibility: Electrician <br />BREAKER PANEL PRIMARY CONTROL PANEL <br />BREAKER SIZE SHOWN IS THE MAXIMUM ALLOWED <br />BREAKER 1PH <br />CONTROL POWER. DO NOT WIRE <br />TO GFCI OR SHUNT TRIP BREAKER. <br />Hot <br />Neutral <br />H1 <br />N1120 V <br />15 A <br />Ground GND <br />1ST HOOD LIGHT BREAKER SHARED W/ CONTROL <br />POWER. SWITCH #1 <br />WIRE TO VFD QUICK CONNECTOR <br />BREAKER 3PH <br />MCA: <br />MOCP: <br />LINE <br />LINE <br />Ground <br />PCU-1 SM-1 <br />GND <br />L1 <br />L2 <br />LINE L3208 V <br />27.9 A <br />40 A <br />BREAKER 3PH <br />WIRE TO VFD QUICK CONNECTOR <br />MCA: <br />MOCP: <br />LINE <br />LINE <br />208 V <br />Ground <br />MAU-1 SM-2 <br />GND <br />L4 <br />L5 <br />LINE L67.6 A <br />15 A <br />BREAKER PANEL TO FANS <br />Responsibility: Electrician <br />BREAKER PANEL FANS <br />POWER TO <br />CONDENSER <br />LINE <br />LINE208-230 <br />20 Amps <br />MAU-1 <br />LINE <br />COND 1 <br />3 PHASE <br />POWER TO <br />CONDENSER <br />LINE <br />LINE208-230 <br />30 Amps <br />MAU-1 <br />LINE <br />COND 2 <br />3 PHASE <br />CONTROL PANEL TO FANS <br />Responsibility: Electrician <br />PRIMARY PANEL FANS <br />Load Wiring <br />WIRE TO <br />VFD QUICK <br />WIRE TO <br />DISCONNECT <br />CONNECTOR <br />MUST HAVE ITS OWN CONDUIT <br />DO NOT SHARE CONDUIT! <br />FLA: <br />HP: <br />VOLT: <br />PCU-101 <br />LOAD LEG 1 <br />LOAD LEG 2 <br />GND GROUND <br />FAN: <br />SM-1 <br />LOAD LEG 3 <br />U1 <br />V1 <br />W1 <br />22.3 <br />7.500 <br />208 V <br />Load Wiring BLACK <br />BLACK <br />BLACK <br />GREEN <br />WIRE TO <br />VFD QUICK <br />CONNECTOR WHITE <br />RED <br />FLA: <br />HP: <br />VOLT: <br />MUST HAVE ITS OWN CONDUIT <br />DO NOT SHARE CONDUIT! <br />IF VFD MOUNTED IN <br />2ND PANEL, WIRE SF <br />SIGNAL FROM PANEL <br />WITH ECPM03. <br />U2 <br />V2 <br />W2 <br />LOAD LEG 1 <br />LOAD LEG 2 <br />LOAD LEG 3 <br />GND GROUND <br />MAU-101FAN: <br />SM-2 <br />N1 120V NEUTRAL <br />120V HOT <br />N1 <br />6.1 <br />2.000 <br />208 V <br />H1 <br />POLLUTION <br />UNIT <br />COMM LINK <br />CONTROL <br />IF MULTIPLE PCUs ON JOB, <br />WIRE EACH CAT-5 IN DAISY <br />CHAIN LOOP, WITH END OF LINE <br />TERMINATOR ON LAST UNIT. <br />CAT-5 ETHERNET CABLE <br />EACH ADDITIONAL UNIT MUST <br />HAVE MODBUS ADDRESS SET. <br />INSIDE PCU <br />J3 <br />ECPM03 <br />J3 <br />CONTROL PANEL TO ACCESSORY ITEMS <br />Responsibility: Electrician <br />CONTROL PANEL COMPONENT <br />ALL SWITCHES FACTORY WIRED <br />CAT-5 CONNECTION <br />CONTROL PANEL <br />SWITCHES <br />TO J4 <br />CONTROL PANEL <br />HOOD LIGHTS <br />TO <br />1400 W MAX WIRE TO J-BOX ON TOP OF HOOD <br />B1 <br />W1 <br />GND <br />BLACK <br />WHITE <br />GREEN <br />HOOD LIGHTS 1 <br />WIRE DIRECTLY TO COMMUNICATION <br />ROUTERCOMM <br />MODULE. NET REQUIRES 1) DHCP 2) <br />UDP PORT 1444 & 1445 OPEN FOR <br />CAT-5 ETHERNET CONNECTION <br />CONTROL PANEL <br />WORLD WIDE <br />TO <br />WEB <br />OUTBOUND TRAFFIC ONLY. <br /> -- <br />WIRE TO CONTROL BOARD. INSTALL <br />SENSOR IN ROOM AWAY FROM HEAT <br />SOURCES. DO NOT INSTALL SENSOR <br />CONTROL PANEL <br />ROOM TEMP <br />TO <br />SENSOR <br />ON THE CEILING GRID, SEE MANUAL. <br />GROUPS: <br />T1A <br />T1B ROOM TEMP <br />FACTORY WIRED TEMPERATURE <br />SENSOR. MOUNTED IN HOOD CAPTURE <br />CONTROL PANEL <br />CAPTURE VOLUME <br />TO <br />SENSOR VOLUME. <br />T2A <br />T2B HOOD 1 <br />CAPTURE 1 <br />FACTORY WIRED TEMPERATURE <br />SENSOR. MOUNTED IN HOOD CAPTURE <br />CONTROL PANEL <br />CAPTURE VOLUME <br />TO <br />SENSOR VOLUME. <br />T3A <br />T3B HOOD 1 <br />CAPTURE 2 <br />WIRE TO CONTROL BOARD. <br />SENSOR MOUNTED IN HOOD CAPTURE <br />CONTROL PANEL <br />CAPTURE VOLUME <br />TO <br />SENSOR VOLUME. <br />T4A <br />T4B HOOD 2 <br />CAPTURE 1 <br />WIRE TO CONTROL BOARD. <br />SENSOR MOUNTED IN SUPPLY PLENUM. <br />CONTROL PANEL <br />PSP SENSOR <br />TO <br />T5A <br />T5B HOOD 2 <br />PSP TEMP <br />CONTROL PANEL <br />PSP LED <br />TO <br />LIGHTS WIRE TO J-BOX ON TOP OF PSP. <br />CONNECT TO RESPECTIVE HOOD <br />LIGHTING CIRCUIT. NOTE: DO NOT <br />HOOD <br />LIGHT <br />INPUT <br />MATCH <br />WIRE IN SERIES WITH HOOD LIGHTS. <br />BLACK <br />WHITE <br />GREEN <br />PSP LIGHTS <br />HOT <br />NEUTRAL <br />GROUND <br />CONTROL PANEL <br />GAS VALVE <br />TO <br />120V ONLY <br />ONLY ENERGIZED THROUGH LCD <br />HMI WHEN FIRE SYSTEM ARMED. <br />GAS <br />N1 <br />HOT TO GAS VALVE <br />NEUTRAL <br />GAS SOLENOID <br />THE FOLLOWING CONNECTIONS <br />MAY OR MAY NOT BE <br />REQUIRED BASED ON JOBSITE <br />SPECIFICATIONS <br />CONTROL PANEL <br />EXTERNAL <br />SIGNAL FOR <br />SHUNT TRIP <br />ST TERMINAL IS ENERGIZED <br />IN FIRE CONDITION. <br />CONTROL PANEL <br />EXTERNAL <br />SIGNAL FOR <br />CONTACTOR COIL <br />KS TERMINAL IS DE-ENERGIZED <br />IN FIRE CONDITION. <br />ST <br />N1 NEUTRAL FROM SHUNT COIL <br />HOT TO SHUNT COIL SHUNT COIL <br />KS <br />N1 NEUTRAL_TO_CONTACTOR_COIL <br />HOT_TO_CONTACTOR_COIL CONTACTOR_COIL <br />SPARE CONTACTS WILL MAKE <br />CONTROL PANEL <br />ON/OFF WITH <br />DRY CONTACT <br />SUPPLY FAN <br />COMMON TO NORMALLY OPEN <br />WHEN SUPPLY FAN IS ON. <br />GROUP 1 <br />SFC1 <br />SFO1 <br />COMMON <br />NORMALLY OPEN <br />SFC2 <br />SFO2 <br />COMMON <br />NORMALLY OPEN <br />CONTROL PANEL <br />EXTERNAL <br />TO <br />SWITCH <br />SIGNAL SWITCH THROUGH BMS <br />WILL ACTIVATE ZONE1 FANS AND <br />LIGHTS <br />H1 <br />IO1 <br />BMS SWITCH <br />C NO <br />CONTROL PANEL <br />GAS VALVE <br />TO <br />24V DC ONLY <br />ONLY ENERGIZED THROUGH LCD <br />HMI WHEN FIRE SYSTEM ARMED. <br />(NOT NEEDED IF USING 120V <br />GAS VALVE). <br />LGV <br />N1D <br />POSITIVE TO GAS VALVE <br />NEGATIVE <br />GAS SOLENOID <br />DESCRIPTION OF OPERATION: <br />6950327 <br />Raising Cane's 1032 <br />SC-311110MA <br />7/2/2025 <br />INSTALL <br />ECP #1-2 <br />3 Phase w/ control for 1 Exhaust Fan, 1 Supply Fan, Exhaust on in Fire, Lights out in Fire, Relay On/Off with Supply Fan, Fan(s) On/Off Thermostatically Controlled. Room <br />temperature sensor shipped loose for field installation. INVERTER DUTY 3 PHASE MOTOR REQUIRED FOR USE WITH VFD. <br />CONTROL PANEL TO FIRE SYSTEM <br />Responsibility: ALARM CONTRACTOR <br />CONTROL PANEL COMPONENT <br />CONTROL PANEL <br />BUILDING <br />SIGNAL FOR <br />FIRE ALARM <br />PANEL <br />AL1 <br />AL2 <br />J9 <br />BUILDING <br />ALARM PANEL <br />FIRE INPUT <br />WIRE DIRECTLY TO CORE CIRCUIT <br />BOARD. AL1 WILL MAKE AL2 IN FIRE <br />CONDITION. <br />CONTROL PANEL <br />BUILDING <br />SIGNAL FOR <br />TROUBLE TROUBLE RELAY CONTACTS WILL <br />MAKE TBC TO TBL IN TROUBLE <br />CONDITION. <br />BUILDING <br />ALARM PANEL <br />ALARM <br />TBC <br />TBL <br />COMMON <br />NORMALLY CLOSED <br />CONTROL PANEL TO FIRE SYSTEM <br />Responsibility: CERTIFIED INSTALLER <br />CONTROL PANEL COMPONENT <br />FIRE STAT SUPERVISED LOOP <br />May be mixed factory and field wiring. See <br />Installation Schematic. Multiple fire sensors <br />possible. <br />HIGH TEMP WIRE (842 F), PN: SLPCON-xFT <br />required for all Supervised Loop wiring in contact <br />with a hood. All other wiring shall be PN: 6320UL, <br />Belden or similar. <br />21 <br />22 <br />23 <br />24 <br />FS-01 <br />BK WH <br />Fire Stat <br />FS-02 <br />BK WH <br />Fire Stat <br />CONTROL PANEL <br />MOUNTED FIRE <br />TO DUCT <br />DETECTION <br />STAT(S) <br />FIRE STATS <br />CONTROL PANEL <br />SYSTEM PULL <br />TO FIRE <br />STATION <br />MANUAL ACTUATION LOOP / REMOTE FIRE SYSTEM <br />LOOP. <br />Multiple manual actuation possible. <br />Multiple manual actuation possible. <br />A Plug jumper with wires from pin1 to pin4 and from pin2 to <br />pin3 is mounted on J10, remove the jumpers and <br />wire in the supervised actuation loop. <br />Microswitch MS-01 is optional for fire <br />system interlock. <br />Auxiliary Interlock (AUX-01): <br />Wire AU1 / AU2 of adjacent Master FS panel(s) in each <br />manual activation loop for simultaneous activation. See Fire <br />system drawings for more information. <br />101 <br />102 <br />103 <br />104 <br />AUX-01 <br />AU1 AU2 <br />PULL STATION <br />MS-01 <br />C NO <br />Micro SW <br />MAD-01 <br />C NO <br />Manual <br />Actuation <br />Device <br />Adjacent <br />FS <br />Panel <br />CAT-5 CONNECTIONCONTROL PANEL <br />MASTER FS <br />TO <br />BOARD. <br />PLACE END OF LINE PLUG <br />EOL120AIN EMPTY JACK. PN: EOL120A <br />CORE PCB <br />ADDITIONAL DEVICES MAY BE INLINE. <br />ECPM03 <br />UNLESS VFD, PCU, <br />OR OTHER COMPONENT IN SERIES. <br />J3 J5 <br />J6 <br />CONTROL PANEL <br />MASTER FS <br />TO <br />PANEL <br />WIRE TO LIKE TERMINALS IN ALL <br />CORE PANELS THAT MUST ACTIVATE <br />TOGETHER. SET MASTER & SLAVE <br />DIP SWITCHES PER FIRE SYSTEM <br />SHIELDED TWISTED PAIRINTERLOCK NETWORK MASTER CORE <br />MANUAL. <br />CA <br />CB <br />CC <br />BLACK <br />RED <br />SHIELD <br />CA <br />CB <br />CC <br />DESCRIPTION OF OPERATION: <br />6950327 <br />Raising Cane's 1032 <br />SC-311110MA <br />7/2/2025 <br />INSTALL <br />ECP #1-3 <br />Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0. <br />FS-1: MASTER <br />DESCRIPTION OF OPERATION: <br />6950327 <br />Raising Cane's 1032 <br />SC-311110MA <br />7/2/2025 <br />INSTALL <br />ECP #1-4 <br />Fire System #1 TANK FS - 4.0 / Remote - 4.0/4.0/4.0. <br />FS-1: MASTER <br />SHEET NO. <br />SCALE: <br />DWG.#: <br />DRAWN <br />DATE: <br /> BY: <br />REVISIONS <br />ww <br />w <br />. <br />c <br />a <br />p <br />t <br />i <br />v <br />e <br />a <br />i <br />r <br />e <br />. <br />c <br />o <br />m <br /> <br /> <br /> <br />AC <br />C <br />O <br />R <br />D <br />A <br />N <br />C <br />E <br />No <br />. <br /> <br />9 <br />6 <br />BU <br />I <br />L <br />T <br />NF <br />P <br />A <br />WI <br />T <br />H <br />IN <br />S <br />LI <br />D <br />TE <br />R <br />6950327 <br />MASTER DRAWING <br />Ra <br />i <br />s <br />i <br />n <br />g <br /> <br />C <br />a <br />n <br />e <br />' <br />s <br /> <br />1 <br />0 <br />3 <br />2 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />1 <br />Lo <br />u <br />i <br />s <br />i <br />a <br />n <br />a <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br />59 <br />0 <br />4 <br />0 <br /> <br />A <br />m <br />b <br />e <br />r <br /> <br />S <br />t <br />r <br />e <br />e <br />t <br />, <br /> <br />S <br />u <br />i <br />t <br />e <br /> <br />B <br />, <br /> <br />S <br />l <br />i <br />d <br />e <br />l <br />l <br />, <br /> <br />L <br />A <br />, <br /> <br />7 <br />0 <br />4 <br />6 <br />1 <br /> <br />P <br />H <br />O <br />N <br />E <br />: <br /> <br />( <br />9 <br />8 <br />5 <br />) <br /> <br />7 <br />8 <br />1 <br /> <br />- <br /> <br />4 <br />1 <br />0 <br />7 <br /> <br />F <br />A <br />X <br />: <br /> <br />9 <br />1 <br />9 <br />7 <br />4 <br />7 <br />5 <br />6 <br />3 <br />7 <br /> <br />E <br />M <br />A <br />I <br />L <br />: <br /> <br />r <br />e <br />g <br />2 <br />7 <br />@ <br />c <br />a <br />p <br />t <br />i <br />v <br />e <br />a <br />i <br />r <br />e <br />. <br />c <br />o <br />m <br />M3.14 <br />HOOD DRAWINGS <br />Te <br />l <br />e <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />0 <br /> <br /> <br />F <br />a <br />x <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />1 <br />68 <br />0 <br />0 <br /> <br />B <br />i <br />s <br />h <br />o <br />p <br /> <br />R <br />o <br />a <br />d <br />, <br /> <br />P <br />l <br />a <br />n <br />o <br />, <br /> <br />T <br />X <br /> <br />7 <br />5 <br />0 <br />2 <br />4 <br />Date: <br />Project Number: <br />Sheet Number: <br />Drawn By: <br />Store: <br />Re <br />s <br />t <br />a <br />u <br />r <br />a <br />n <br />t <br /> <br />S <br />u <br />p <br />p <br />o <br />r <br />t <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br />RAC23003.0 <br />07.12.2024 <br />MAM & JJD <br />Sheet Title: <br />1 <br />07.01.2024 VERSION 2024-1.0 RELEASE <br />Prototype : <br />Date Issued:Bulletin Number: <br />Design Bulletin Updates: <br />Prototype Issue Date: <br />- <br />2 <br />3 <br />REVISIONS: <br />4 <br />5 <br />6 <br />7 <br />A <br />9 <br />Kitchen Issue Date: <br />10 <br />Raising Cane's <br />Restaurant #C1032 <br />1303 N. Bristol st. <br />Santa Ana, CA 92706 <br />P6E-HV Scheme B <br />09 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />R <br />E <br />V <br />I <br />S <br />I <br />O <br />N <br /> <br />- <br /> <br />B <br />U <br />L <br />L <br />E <br />T <br />I <br />N <br /> <br />1 <br />09/05/24 BLDG. SUBMITTAL <br />PERMIT SET <br />P6E-AV SCHEME B 2024-1.0 <br />07.01.2024 <br />Check By:MMM <br />07.01.2024 <br />09/27/24 PLANNING RESPONSE <br />11/01/24 HEALTH DEP. RESUBMITTAL <br />12/12/24 HEALTH DEP. RESUBMITTAL <br />1/20/25 BUILDING. RESUBMITTAL <br />2/21/25 BUILDING. RESUBMITTAL <br />05/02/2025 BID SET <br />06/25/2025 CONSTRUCTION SET <br />09/12/2025 PERMIT REVISION <br />Professional of Record: <br />19401 40TH AVE W <br />SUITE 420 <br />LYNNWOOD, WA 98036 <br />CONTACT: MARK MANGLICMOT, P.E. <br />(425) 516-7882 <br />MMANGLICMOT@PMDGINC.COM <br />09/12/25 <br />MARK MANGLICMOT, PE <br />A