Laserfiche WebLink
120v <br />D/T WINDOW <br />RETURN <br />1' <br />- <br />6 <br />" <br />120v <br />3'-10" <br />120v <br />4' <br />- <br />0 <br />" <br />120v <br />10"8" <br />612"1'-4" <br />FIXEDOPEN <br />1 ELEVATION (Drive-Thru Beverage & Ice Area) <br />3/8"= 1'-0" <br />FS3.1 2 ELEVATION (Cookline & D/T Pickup) <br />3/8"= 1'-0" <br />FS3.1 <br />3 ELEV <br />3/8"= 1'-0" <br />FS3.1 5 ELEVATION (Prep) <br />3/8"= 1'-0" <br />FS3.14ELEV/Prep <br />3/8"= 1'-0" <br />FS3.1 6 ELEV/Prep <br />3/8"= 1'-0" <br />FS3.1 7 ELEV/Pay WDW <br />3/8"= 1'-0" <br />FS3.1 8 ELEV/Pay WDW <br />3/8"= 1'-0" <br />FS3.1 9 ELEV/Pay WDW <br />3/8"= 1'-0" <br />FS3.1 10 ELEVATION (Electrical Panels) <br />3/8"= 1'-0" <br />FS3.1 <br />11 ELEVATION (Cookline Support Line) <br />3/8"= 1'-0" <br />FS3.1 12 ELEVATION (Toast Line) <br />3/8"= 1'-0" <br />FS3.1 13 ELEVATION (Bread Rack, Hand Sink, Lockers) <br />3/8"= 1'-0" <br />FS3.1 <br />1' <br />- <br />6 <br />" <br />FW-A <br />4' <br />- <br />0 <br />" <br />9" <br />HW <br />1'-0" <br />6" <br />4' <br />- <br />0 <br />" <br />6" <br />4'-9" <br />5' <br />- <br />6 <br />" <br />5' <br />- <br />0 <br />" <br />4" PVC CHASE FOR COKE <br />BUNDLE, STUB ABOVE <br />CEILING, ELBOW AT WALL <br />PENETRATION ON <br />DRIVE-THRU SIDE. <br />4' <br />- <br />0 <br />" <br />2'-4" <br />2' <br />- <br />0 <br />" <br />1'-10"1'-2" <br />2' <br />- <br />0 <br />" <br />3'-9" <br />2'-4" <br />1'-0" <br />6' <br />- <br />4 <br />" <br />6'-9" <br />2'-6" <br />4" PVC CHASE FOR ICE <br />CONDENSERS, STUB ABOVE <br />CEILING, ELBOW AT WALL <br />PENETRATION ON DRIVE-THRU SIDE <br />1'-10"1'-8" <br />6"8" <br />KDS MONITOR <br />DIMENSION FROM CORNER AT WALL, TO CLEAR <br />OPENING IN THE HOOD CANOPY. CONTROL PANEL <br />WILL EXTEND BEYOND TO THE LEFT <br />17'-10" <br />2'-1" <br />4' <br />- <br />6 <br />" <br />STUB 1.5" E.C. ABOVE CEILING, TO SHARED <br />BACK OF HOUSE AREA, DOWN TO MUD RING. <br />(PROVIDE PULL STRING) <br />5' <br />- <br />6 <br />" <br />9'-33 4"COMM. LINES 3,4 & KP-2; TO OFFICE; PHONE LINE 3 <br />BUMP BAR IN WINDOW RETURN <br />HOOD ELECTRICAL CONTROL AND ANSUL CABINETS <br />6"MIN. CLEARANCE EDGE OF COOKING SURFACE TO EDGE OF HOOD <br />CANOPY (VERIFY CODE) <br />GAS LINE TO BE PER <br />DRAWINGS AND ANY CODES <br />4" <br />CLEAR OPEN AREA OF CANOPY <br />CONTROL/ANSUL/ELECTRIAL PANEL FOR HOOD. ALL HOOD PLACEMENT DIMENSIONS ARE <br />TO OPEN PART OF CANOPY (VERIFY WHICH END(S) THIS UNIT IS INSTALLED ON)6" <br />STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO MUD RING. (PROVIDE PULL STRING)3/4" GALVANIZED GREASE DISPOSAL PIPING <br />STUBBED TO ACTUAL OR FUTURE PLANNED <br />LOCATION. NEED TO LEAVE CLEARANCE FOR 4" <br />COVER OVER PIPE. (VERIFY WITH OWNER) <br />7'-11"6" <br />1' <br />- <br />6 <br />" <br />6" <br />KDS MONITOR <br />GAS LINE <br />1' <br />- <br />0 <br />" <br />3'-3"3'-7" <br />9"9" <br />2' <br />- <br />0 <br />" <br />1' <br />- <br />6 <br />" <br />3'-3"3'-3" <br />DARPRO LINE <br />2'-6" <br />6' <br />- <br />0 <br />" <br />1' <br />- <br />6 <br />" <br />3'-6" <br />9"8" <br />STUB JBOX & 3 4" E.C. IN <br />DRYWALL WINDOW <br />RETURN, ABOVE CEILING <br />FOR MICROPHONE <br />4' <br />- <br />6 <br />" <br />4' <br />- <br />6 <br />" <br />1'-3" <br />4' <br />- <br />6 <br />" <br />DUPLEX RECEPTACLE, INSIDE 8X8 BOX, <br />TO FACE LENGTH OF 8X8 BOX. <br />8x8 J-BOX, WITH (1) 2" RIGID CONDUIT FOR <br />WIRELESS BASE (HME) (STUB ABOVE CEILING) <br />5' <br />- <br />0 <br />" <br />STUB 1-1/2" E.C. ABOVE CEILING <br />AND DOWN TO TWO MUD RINGS. <br />(PROVIDE PULL STRING(S)). <br />6' <br />- <br />0 <br />" <br />1'-2"6" <br />7'-1" <br />2' <br />- <br />3 <br />" <br />1'-11"4" <br />DRIVE-THRU MONITOR <br />(SHARED) <br />STUB 1-1/2" E.C. ABOVE <br />CEILING, DOWN TO TWO MUD <br />RINGS FOR DATA TO EACH <br />REGISTER AND MONITOR ON <br />WALL <br />STUB 3 4" E.C. ABOVE CEILING <br />OUT TO DRIVE-THRU SPEAKER <br />POST FOR WIRING AND LOOP <br />DETECTOR (PROVIDE PULL <br />STRING) <br />OUTLET FOR WIRELESS HEADSET <br />CHARGING <br />7' <br />- <br />6 <br />" <br />1'-8" <br />1' <br />- <br />6 <br />" <br />DRIVE-THRU CANOPY BACKLIT <br />SWITCH (S) <br />STUB 1 1/2" E.C. ABOVE CEILING <br />OUT TO CANOPY AMENITIES <br />(PROVIDE PULL STRING) <br />6" <br />2'-9" <br />2' <br />- <br />0 <br />" <br />CEILING DUPLEX RECEPTACLE AT CEILING <br />MONITOR POST SUPPORT <br />BLOCKING NEEDED FOR <br />MOUNTING POST <br />5'-6" <br />HOOD <br />6" <br />7' <br />- <br />0 <br />" <br />4"1'-4" <br />3'-9" <br />1'-6" <br />7' <br />- <br />0 <br />" <br />8' <br />- <br />6 <br />" <br />GREASE DISPOSAL REMOTE CONTROL <br />PANEL UNIT AND HARNESS BY OTHERS. <br />30 FT. LATERAL DISTANCE FROM <br />DISPOSAL TANK <br />6' <br />- <br />6 <br />" <br />KDS <br />STUB 1.5" E.C. ABOVE CEILING, THEN DOWN TO MUD RING. (PROVIDE PULL STRING) <br />6' <br />- <br />0 <br />" <br />1' <br />- <br />6 <br />" <br />4' <br />- <br />2 <br />" <br />6"5" <br />6"7" <br />1' <br />- <br />6 <br />" <br />1'-0" <br />4" <br />6" <br />1' <br />- <br />6 <br />" <br />1'-3" <br />Te <br />l <br />e <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />0 <br /> <br /> <br />F <br />a <br />x <br />: <br /> <br />9 <br />7 <br />2 <br />- <br />7 <br />6 <br />9 <br />- <br />3 <br />1 <br />0 <br />1 <br />68 <br />0 <br />0 <br /> <br />B <br />i <br />s <br />h <br />o <br />p <br /> <br />R <br />o <br />a <br />d <br />, <br /> <br />P <br />l <br />a <br />n <br />o <br />, <br /> <br />T <br />X <br /> <br />7 <br />5 <br />0 <br />2 <br />4 <br />Date: <br />Project Number: <br />Sheet Number: <br />Drawn By: <br />Store: <br />Re <br />s <br />t <br />a <br />u <br />r <br />a <br />n <br />t <br /> <br />S <br />u <br />p <br />p <br />o <br />r <br />t <br /> <br />O <br />f <br />f <br />i <br />c <br />e <br />RAC23003.0 <br />07.12.2024 <br />LL <br />Sheet Title: <br />1 <br />07.01.2024 VERSION 2024-1.0 RELEASE <br />Prototype : <br />Date Issued:Bulletin Number: <br />Design Bulletin Updates: <br />Prototype Issue Date: <br />- <br />2 <br />3 <br />REVISIONS: <br />4 <br />5 <br />6 <br />7 <br />A <br />9 <br />Professional of Record:JEFF LIEDERMAN <br />Kitchen Issue Date: <br />10 <br />76 E. MITCHELL DR. <br />PHOENIX, AZ 85012 <br />CONTACT: CHUCK BENNETT <br />(623) 432-0596 <br />CBENNETT@PMDGINC.COM <br />Raising Cane's <br />Restaurant #C1032 <br />1303 N. Bristol st. <br />Santa Ana, CA 92706 <br />P6E-HV Scheme B <br />09 <br />/ <br />1 <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />P <br />E <br />R <br />M <br />I <br />T <br /> <br />R <br />E <br />V <br />I <br />S <br />I <br />O <br />N <br /> <br />- <br /> <br />B <br />U <br />L <br />L <br />E <br />T <br />I <br />N <br /> <br />1 <br />09/05/24 BLDG. SUBMITTAL <br />PERMIT SET <br />P6E-AV SCHEME B 2024-1.0 <br />07.01.2024 <br />Check By:CB <br />07.01.2024 <br />09/27/24 PLANNING RESPONSE <br />11/01/24 HEALTH DEP. RESUBMITTAL <br />12/12/24 HEALTH DEP. RESUBMITTAL <br />1/20/25 BUILDING. RESUBMITTAL <br />2/21/25 BUILDING. RESUBMITTAL <br />05/02/2025 BID SET <br />06/25/2025 CONSTRUCTION SET <br />09/12/2025 PERMIT REVISION <br />EQUIPMENT <br />ELEVATIONS <br />FS3.20 <br />2 <br />3 <br />A