My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2422 W Marty Ln Unit 2 & 3 - Plan
PBA
>
Building
>
ProjectDox
>
M
>
Marty Ln
>
2422 W Marty Ln Unit# 2
>
2422 W Marty Ln Unit 2 & 3 - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2025 5:00:15 AM
Creation date
11/21/2025 5:00:05 AM
Metadata
Fields
Template:
Plan
Permit Number
101124651
101124652
Full Address
2422 W Marty Ln Unit# 2
2422 W Marty Ln Unit# 3
Street Number
2422
Street Direction
W
Street Name
Marty
Street Suffix
Ln
Unit Number
3
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
DESCRIPTION: CJ-1@ 16" OC <br />CODE REFERENCES <br />Project Title: <br />Engineer: <br />Project ID: <br />Project Oeser: <br />·. ·f:~'~;~~~~rt~,~c~J <br />NERCALC INC 1983-2023 <br />-·--···---······· -----·········-·--·-·-··----·-----·· --------------------------------- <br />Calculations per NDS 2018, IBC 2021, ASCE 7-16 <br />Load Combination Set: ASCE 7-16 <br />fti~_¥li~!i~i_fn"2P~i!i~~---__________ _ <br />Analysis Method : Allowable Stress Design <br />Load Combination ASCE 7-16 <br />Wood Species <br />Woocl Grade <br />Douglas Fir-Larch <br />No.2 <br />Fb + <br />Fb- <br />Fe-Prll <br />Fe-Perp <br />Fv <br />Ft <br />Elearn Bracing Beam is Fully Braced against lateral-torsional buckling <br />.. ··---····-----·--··--·.,--·---··-·----··--·--·-· <br />r- <br />Span = 16.750 ft <br />900.0 psi <br />900.0 psi <br />1,350.0 psi <br />625.0 psi <br />180.0 psi <br />575.0 psi <br />E : Modulus of Elasticity <br />Ebend-xx 1 ,600.0 ksi <br />Eminbend-xx 580.0ksi <br />Density 31.210pcf <br />Repetitive Member Stress Increase <br />A~pii~(i_!:::l()~_!!~ --·--------------Service loads entered. Load Factors will be applied for calculations. <br />Beam self weight calculated and added to loading <br />Uniform Load : D = 0.01 0, Lr = 0.010 ksf, Tributary Width = 1.333 ft, (Ceiling Loads) <br />DE:$1Gif1! $ [JlVIJVIA BY ... <br />l'v1aximum Bending Stress Ratio 0.599: 1 Maximum Shear Stress Ratio 0.139: 1 <br />Section used for this span 2x8 Section used for this span 2x8 <br />fb: Actual 929.30psi fv: Actual = 31.32 psi <br />F'b 1 ,552.50psi F'v = 225.00 psi <br />Load Combination +D+Lr Load Combination +D+Lr <br />Location of maximum on span = 8.375ft Location of maximum on span = 16.200 ft <br />Span #where maximum occurs = Span# 1 Span #where maximum occurs = Span# 1 <br />Maximum Deflection <br />1\ilax Downward Transient Deflection 0.312 in Ratio= 645>=360 Span: 1 : Lr Only <br />1\ilax Upward Transient Deflection 0 in Ratio= 0<360 n/a <br />1\ilax Downward Total Deflection 0.678 in Ratio= 296>=180 Span: 1 : +D+Lr <br />IVIax Upward Total Deflection 0 in Ratio= 0<180 n/a <br />Maximum Forces & Stresses for Load Combinations <br />· Eaac0i,bln:illon ______ l\7lax Stress Ratios lllloment 17alues Snear 17alues <br />Segment Length Span# M v <br />--~--· ----~-------~--- <br />CD CM Ct CLx CE Cfu ci cr M fb F'b v fv F'v <br />D Only 0.0 0.00 0.0 0.0 <br />Length == 16. l50 ft 0.449 0.105 0.90 1.00 1.00 1.00 1.200 1.00 1.00 1.15 0.55 502.4 1,117.8 0.12 16.9 162.0 <br />HJ+lr 1.00 1.00 1.00 1.200 1.00 1.00 1.15 0.0 0.00 0.0 0.0 <br />Len 9th = 16.750 ft 0.599 0.139 1.25 1.00 1.00 1.00 1.200 1.00 1.00 1.15 1.02 929.3 1,552.5 0.23 31.3 225.0 <br />+D+0.750Lr 1.00 1.00 1.00 1.200 1.00 1.00 1.15 0.0 0.00 0.0 0.0 <br />l..r:mgth "' 16.750 ft 0.530 0.123 1.25 1.00 1.00 1.00 1.200 1.00 1.00 1.15 0.90 822.6 1,552.5 0.20 27.7 225.0 <br />+0.60D 1.00 1.00 1.00 1.200 1.00 1.00 1.15 0.0 0.00 0.0 0.0 <br />Len\)tfl = 16.'750 ft 0.152 0.035 1.60 1.00 1.00 1.00 1.200 1.00 1.00 1.15 0.33 301.4 1,987.2 0.07 10.2 288.0
The URL can be used to link to this page
Your browser does not support the video tag.