My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20163957 - Permit
PBA
>
Building
>
Permits
>
N
>
Newhope St
>
205 S Newhope St
>
20163957 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 8:16:33 AM
Creation date
7/28/2021 8:16:32 AM
Metadata
Fields
Template:
Permit
Permit Number
20163957
Full Address
205 S Newhope St
Permit ID
233286
Master ID Number
2017-138158
Project Name
Miscellaneous Counter1 Permit
Street Number
000205
Street Direction
S
Street Name
Newhope
Street Suffix
St
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
8/21/2017
Issued Date
8/21/2017
Finalized Date
1/10/2018
Flood Zone
A-0602320256J
Description of Work
Install (20) roof mounted solar panels. FEES PD ON 10193907
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
8
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />System AC Size <br />Site Address <br />Site Name <br />MoDULE MAKE Jinko SolarLI <br />MoDULE MoDEL J K i,4 28 OT\,4 -60 B <br />MAX POWER.POINT CL'RRENT IIMJ <br />MAX POWER.POINT VOLTAGE (VME) <br />OPEN.CIRCUIT VOLTAGE (VOJ <br />sHoRI-CtRCUtT CURRENT {tsc) <br />MAX SERIES FUSE (OCPD) <br />i lAxtltuM Polf:R (Ph) <br />8.81 <br />31.8 <br />38.6 <br />9.53 <br />20 <br />PV MODULE RATINGS @ STC (Gurde Seclron 5) <br />NOTES FOR ALL ORAWINGS <br />INVERTER RATINGS (Gurde Section 4) <br />INVERTERMAKE SOTAREDGEI <br />TNVERTER MoDEL SE5000 <br />MAX OC VOLT RATING <br />MAX POWER @ 40€ <br />I <br />NOMINAL AC VOLTAGE <br />MAX AC CURRENT <br />MAX OCPD RATING <br />SIGNS-SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECT <br />PHOIOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT 8 A <br />RATED MPP VoLTAGE 350 v <br />MAx SYSTEM VoLTAGE 374.5 v <br />MAX crRcurr CURRENT 20 A <br />WARNING: ELECTRICAL SHOCK <br />HAZARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />OCPD : OVERCURRENT PROTECTION DEVICE <br />NAIIONAL ELECTRICAL COOE' REFERENCES <br />sHowN AS lruEC XXX.XX' <br />r11x YgLrlcE {rY1 gggv!!) <br />VOC TEMP COEFF (mV/.Ctr or %PC O) <br />2ao <br />600 <br />-0.3 <br />500 <br />5000 <br />240 <br />21 <br />30 <br />_Y <br />-1 <br />SIGN FOR INVERTER OCPD AND <br />AC DISCONNECT (IF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />NoTES FOR ARRAY CIRCUIT WIRING (Guda Soclton 6 and 8 and Appendrx o) <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />NoTES FOR INVERTER CIRCUITS (cud€ Secton 8 and 9) <br />1)IF UTILITY REOUIRES AVISIBLE.BREAK SWITCH, DOES THIS SWITCH MEET THE <br />REQUIREMENT? YES N NOE] N/AD <br />2) IF GENERATION METER REOUIRED, DOES THIS METER SOCKET MEET THE <br />REQUIREMENT? YES X NO D N/A E <br />l)SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONOUC'ORS BASEO ON MAx <br />CURRENT ON NEC 690,53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIlE INVFRTFR OL'TPUT CIRCUIT (AC) CONOUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING {See Gude Secton 9J <br />5) TOTAL OF , INVERTER OCPO(S), ONE FOR EACH INVERTER. DOES TOTAL <br />SUPPlY AREAKERS COMPLY WITH 120olD BUSBAR EXCEPTION lN 690.64{8X2)(a)? <br />YES E] NO tr <br />AC oUTPUT oURRENT 21 <br />NOMINAL AC VoLTAGE 24O <br />1 ) LOWESI EXPECT AMBIENT TEMPERATURE AASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERAIURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION LOWEST EXPECTED AMBIENT TEMP r 'C <br />2 ) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION HIGHEST CONTINUOUS TEMPERATURE ,, tC <br />2 ) 2OO5 ASHRAE FUNDEMENTALS 2% DESIGN TEMPERATURES DO NOT EXCEED <br />47'C IN THE UNITED STATES {PALM SPRINGS, CA IS 44 1'C). FOR LESS THAN 9 <br />CURRENT-CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT <br />LEAST 0,5' ABOVE ROOF AND USING THE OUTOOOR DESIGN TEMPERATURE OF <br />47.C OR LESS (ALL OF UNTTEO STATES), <br />a) I2 AWG, gO.C CONDUCTORS ARE OENERALLY ACCEPTABLE FOR MODLI ES <br />WITH lsc OF 7.68 AMPS OR LESS WHEN PROTECTED BY A 1?-AMP OR SMALLER <br />FUSE <br />b) 1O AWG, gO'C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH lsc OF 9.6AMPS OR LESS WHEN PROTECTED BY A ItAMP OR SMALLER <br />FUSE, <br />NTS <br />NO I[:S I'OII S I'ANI)AI{D S'IIIINC SYS'I'I.M EI [(]TI{ICAI [)IACIiANI <br />F <br />:- <br />a <br />A