My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10180813_2118 W. 12TH - Plan
PBA
>
Building
>
Plans
>
T
>
Twelfth St
>
2118 W Twelfth St
>
10180813_2118 W. 12TH - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/1/2021 5:27:33 PM
Creation date
10/25/2020 5:41:44 PM
Metadata
Fields
Template:
Plan
Permit Number
10180813
Full Address
2118 W Twelfth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
i LUL Pool <br />engineering <br />- inc <br />POOL ENGINEERING INC.By: DEBBIEM <br />Location: Santa Ana, CA,92703-1928 Date: 3/3/2014 <br />Job# 14-0360 <br />PROJECT DATA: <br />- Proiect Location: <br />2118 W 12th St <br />Santa Ana, CA,92703-1928 <br />Existing Residence: <br />Roof Area:1505 ftz <br />Upper Floor Area:N/A <br />Lower Floor Area:N/A <br />Numberof Stories: 1 <br />Site Properties: <br />Latitude: 33.755 <br />Longitude: -117.9 <br />Ss = 1.395 (g) 0.2s Spectral Response Acceleration <br />Sl = 0.496 (g) 1.Os Spectral Response Acceleration <br />Site Class: D (ASCE 7-10, Section 11.4.2) <br />Fa = 1.00 Site Coefficient (ASCE 7-10, Table 11.4-1) <br />Fv= 1.60 Site Coefficient (ASCE 7-10, Table 11.4-2) <br />SDS = 0.9300 Short Period Design Spectral Acceleration Parameter (ASCE 7-10, Eqn. 11.4-3) <br />S[)1 = 0.5291 ls Period Design Spectral Acceleration Parameter (ASCE 7-10, Eqn. 11.4-4) <br />Wind Speed = 110 mph (basic wind speed) <br />Exposure Category: C <br />Product Information: <br />Manufacturer: PHONO SOLAR' <br />Model: PS300P <br />Weight:2.92 p.s.f. (including mounting system) <br />Installed Area: 209.08 ft2 <br />Design Criteria: <br />C. B.C. 2013 <br />ASCE 7-10 <br />Design Methodologv: <br />Per the exception in Section 3403.4 of the C.B.C. 2013: <br />"Any existing lateral load-carrying structural element whose demand-capacity ratio with the addition considered is no more than 10 percent greater than <br />its demand-capacity ratio with the addition ignored shall be permitted to remain unaltered" <br />This calculation will verify whether or not the increased loads imposed by the addition, will result in an increase of 10% or less of a demand in <br />the existing structure. If ithe demand increase is within 10% of the original demand-capacity ratio, no retrofit shall be required. <br />3/3/20144:16 PM <br />\\peanasv2\pool\Projects Solar\2014\0360-14 Residential\14-0360 SOLAR PANEL CALCS.xlsx <br />Page 7 of 13 <br />©Pool Engineering, Inc. 2014 <br />• n
The URL can be used to link to this page
Your browser does not support the video tag.