<br />Trimar Engineering
<br />CM
<br />Better Buzz PO Menu & Canopy
<br />Checked By : CM
<br />RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 19
<br />Member Area Loads (BLC 5 : Wind Load Case B2) (Continued)
<br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
<br />3 N4 N9 N8 N7 Perp Two Way -0.0233 -0.0233 -0.0233 -0.0233
<br />4 N2 N5 N6 N3 Perp Two Way -0.0254 -0.0254 -0.0254 -0.0254
<br />Member Area Loads (BLC 6 : Wind Load Case A3)
<br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
<br />1 N22 N23 N11 N10 Perp Two Way -0.0174 -0.0174 -0.0174 -0.0174
<br />Member Area Loads (BLC 7 : Wind Load Case B3)
<br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
<br />1 N22 N23 N11 N10 Perp Two Way 0.0072 0.0072 0.0072 0.0072
<br />Member Area Loads (BLC 8 : Roof cover, Cabinet DL)
<br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces
<br />1 N11 N10 N22 N23 Y Two Way -0.003 -0.003 -0.003 -0.003
<br />2 N9 N8 N7 N4 Y Two Way -0.004 -0.004 -0.004 -0.004
<br />3 N2 N5 N6 N3 Y Two Way -0.004 -0.004 -0.004 -0.004
<br />Member Distributed Loads (BLC 2 : Wind Load Case A1)
<br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
<br />1 M1 X -0.013 -0.013 0 1
<br />2 M1 X -0.013 -0.013 5.75 9.39
<br />Member Distributed Loads (BLC 3 : Wind Load Case B1)
<br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
<br />1 M1 X -0.013 -0.013 0 1
<br />2 M1 X -0.013 -0.013 5.75 9.39
<br />Member Distributed Loads (BLC 4 : Wind Load Case A2)
<br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
<br />1 M1 X 0.013 0.013 0 1
<br />2 M1 X 0.013 0.013 5.75 9.39
<br />Member Distributed Loads (BLC 5 : Wind Load Case B2)
<br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
<br />1 M1 X 0.013 0.013 0 1
<br />2 M1 X 0.013 0.013 5.75 9.39
<br />Member Distributed Loads (BLC 6 : Wind Load Case A3)
<br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
<br />1 M1 Z 0.013 0.013 0 %100
<br />Member Distributed Loads (BLC 7 : Wind Load Case B3)
<br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)]
<br />1 M1 Z 0.013 0.013 0 %100
|