Company <br />Designer <br />Job Number <br />Model Name <br />: <br />: <br />: <br />: <br />Trimar Engineering <br />CM <br />Better Buzz PO Menu & Canopy <br />Checked By : CM <br />RISA-3D Version 22 [ Better Buzz PO Menu & Canopy.r3d ] Page 19 <br />Member Area Loads (BLC 5 : Wind Load Case B2) (Continued) <br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces <br />3 N4 N9 N8 N7 Perp Two Way -0.0233 -0.0233 -0.0233 -0.0233 <br />4 N2 N5 N6 N3 Perp Two Way -0.0254 -0.0254 -0.0254 -0.0254 <br />Member Area Loads (BLC 6 : Wind Load Case A3) <br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces <br />1 N22 N23 N11 N10 Perp Two Way -0.0174 -0.0174 -0.0174 -0.0174 <br />Member Area Loads (BLC 7 : Wind Load Case B3) <br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces <br />1 N22 N23 N11 N10 Perp Two Way 0.0072 0.0072 0.0072 0.0072 <br />Member Area Loads (BLC 8 : Roof cover, Cabinet DL) <br />Node A Node B Node C Node D Direction Load DirectionA Magnitude [ksf]B Magnitude [ksf]C Magnitude [ksf]D Magnitude [ksf]Exclude Braces <br />1 N11 N10 N22 N23 Y Two Way -0.003 -0.003 -0.003 -0.003 <br />2 N9 N8 N7 N4 Y Two Way -0.004 -0.004 -0.004 -0.004 <br />3 N2 N5 N6 N3 Y Two Way -0.004 -0.004 -0.004 -0.004 <br />Member Distributed Loads (BLC 2 : Wind Load Case A1) <br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)] <br />1 M1 X -0.013 -0.013 0 1 <br />2 M1 X -0.013 -0.013 5.75 9.39 <br />Member Distributed Loads (BLC 3 : Wind Load Case B1) <br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)] <br />1 M1 X -0.013 -0.013 0 1 <br />2 M1 X -0.013 -0.013 5.75 9.39 <br />Member Distributed Loads (BLC 4 : Wind Load Case A2) <br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)] <br />1 M1 X 0.013 0.013 0 1 <br />2 M1 X 0.013 0.013 5.75 9.39 <br />Member Distributed Loads (BLC 5 : Wind Load Case B2) <br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)] <br />1 M1 X 0.013 0.013 0 1 <br />2 M1 X 0.013 0.013 5.75 9.39 <br />Member Distributed Loads (BLC 6 : Wind Load Case A3) <br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)] <br />1 M1 Z 0.013 0.013 0 %100 <br />Member Distributed Loads (BLC 7 : Wind Load Case B3) <br />Member Label Direction Start Magnitude [k/ft, F, ksf, k-ft/ft] End Magnitude [k/ft, F, ksf, k-ft/ft] Start Location [(ft, %)] End Location [(ft, %)] <br />1 M1 Z 0.013 0.013 0 %100