Laserfiche WebLink
18x48 <br />5-tier <br />18x42 <br />18 <br />x <br />6 <br />0 <br />5- <br />t <br />i <br />e <br />r <br />18x48 <br />5-tier <br />18x42 <br />18 <br />x <br />6 <br />0 <br />5- <br />t <br />i <br />e <br />r <br />NOTE: <br />DIMENSIONS SHOWN ARE ACTUAL DIMENSIONS <br />2"2'-10"4" <br />13 <br />- <br />9 <br />- <br />7' <br />- <br />1 <br />" <br />10'-11" <br />KEYNOTES: <br />REFER TO EQUIPMENT SCHEDULE ON SHEET K2.1 -K2.2 FOR MORE INFORMATION. <br />4-TIER COOLER STORAGE SHELVING <br />WALK-IN COOLER WITH LIGHT KIT <br />EVAPORATOR COIL FOR WALK-IN COOLER <br />SCALE <br />1/2" = 1'-0"DETAIL 2 <br />SELF CLOSING HINGES <br />2" DIAL THERMOMETER <br />PILOT SWITCH <br />84" FLUSH BOTTOM DOOR <br />SCALE <br />3/8" = 1'-0" <br />DOOR @ COOLER <br />KICK PLATE (32"X32") <br />NOTE: <br />NO DIAMOND PLATE FINISH WILL BE USED <br />FOR THE INTERIOR AND EXTERIOR OF <br />THE WALK-IN FREEZER & COOLER, <br />INCLUDING THE DOOR KICKPLATE <br />WA <br />L <br />L <br /> <br />P <br />E <br />R <br /> <br />P <br />L <br />A <br />N <br />4" <br /> <br />M <br />I <br />N <br />. <br />AI <br />R <br /> <br />G <br />A <br />P <br />WALK-IN WALL <br />BACKER-ROD <br />& SEALANT <br />FULL LENGTH .040 ALUM. <br />CLOSURE ANGLE W/ HEMMED <br />EDGES W/ SILICONE BEAD <br />CONT. EACH SIDE <br />SCALE <br />3" = 1'-0" <br />FLASHING @ W.I.C. <br />EXTERIOR WALL <br />SCALE <br />N.T.S. <br />NOTE: <br />SEE SHEET T1.1 DEFERRED SUBMITTAL <br />FOUNDATION DETAILS AND ADDITIONAL NOTES. TO BE PROVIDED AT TIME OF SUBMITTAL. <br />G.C. TO COMPLY WITH ALL W.I.B. MANUFACTURER RECOMMENDATIONS FOR <br />PREPARATION AND INSTALLATION OF W.I.B. SLAB. <br />COOLER REFRIGERATION SHALL BE SIZED TO MAINTAIN 34 DEG. F. FREEZER <br />REFRIGERATION SHALL BE SIZED TO MAINTAIN -10 DEG. F. WALK-IN COOLER SHALL BE <br />PROVIDED WITHOUT FLOOR. WALK-IN FREEZER SHALL BE PROVIDED WITH 4" INSULATED <br />FLOOR AND INTERIOR RAMP AT DOOR. <br />THE WALK-IN MANUFACTURER WILL PROVIDE: <br /> 1) THE WALK-IN COOLER & FREEZER <br /> 2) REFRIGERATION EQUIP. SIZED TO MEET BETTER BUZZ REQUIREMENTS, FACTORY <br />ASSEMBLED AND WITH LOW AMBIENT CONTROLS, INCLUDING ALL WIRING, <br />REFRIGERATION PIPING, W/ REMOTE UNITS MOUNTED ON S.S. RAILS LOCATED ON <br />THE ROOF, AND READY FOR FINAL CONNECTION TO ALL NECESSARY UTILITIES. <br /> 3) DELIVERY OF THE BOXES <br /> 4) CONTRACTOR TO INSTALL WALK-IN BOX AND REFRIG. <br />IT SHALL BE THE RESPONSIBILITY OF THE G.C. TO CONTACT WALK-IN BOX PROVIDER AND <br />OBTAIN A COPY OF THE SHOP DRAWINGS FOR THIS PROJECT PRIOR TO ROUGH IN OF <br />UTILITIES. FAILURE TO OBTAIN SHOP DRAWINGS PRIOR TO ROUGH IN WILL NOT RESULT IN <br />EXTRA CHARGES TO THE OWNER FOR RELOCATION OF UTILITIES. <br />W.I.B. NOTES <br />DE <br />T <br />A <br />I <br />L <br />S <br />A8.1 <br />913 <br />10 <br />12 <br />S H E E T N U M B E R <br />A2641 <br />Pl <br />o <br />t <br />t <br />e <br />d <br />: <br /> <br />10 <br />/ <br />2 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />1 <br />1 <br />: <br />0 <br />2 <br /> <br />P <br />M <br /> ( <br />la <br />u <br />r <br />e <br />) <br /> <br />F <br />i <br />l <br />e <br />: <br /> <br />21 <br />_ <br />a <br />2 <br />6 <br />4 <br />1 <br />_ <br />a <br />8 <br />. <br />1 <br />_ <br />d <br />e <br />t <br />a <br />i <br />l <br />s <br />. <br />d <br />w <br />g <br />PROJECT NUMBER <br />2025.10.03 <br />DATE <br />R E V I S I O N S <br />S T A M P <br />SHEETS BEARING THIS SEAL AND WET SIGNATURE <br />ARE AUTHENTICATED. RESPONSIBILITY FOR ALL <br />OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS <br />ARE DISCLAIMED. <br />P <br />R <br /> <br />O <br /> <br />J <br /> <br />E <br /> <br />C <br /> <br />T <br />L <br />O <br /> <br />C <br /> <br />A <br /> <br />T <br /> <br />I <br /> <br />O <br /> <br />N <br />C O N S U L T A N T <br />S <br />H <br /> <br />E <br /> <br />E <br /> <br />T <br /> <br /> <br /> <br />T <br /> <br />I <br /> <br />T <br /> <br />L <br /> <br />E <br />C COPYRIGHT 2025 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL. <br />16 <br />0 <br />1 <br /> <br />N <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />Kevin MacDonald <br />801 University Avenue <br />San Diego, CA 92103 <br />kevin.macdonald@betterbuzzcoffee.com <br />9431 HAVEN AVENUE, SUITE 212 <br />RANCHO CUCAMONGA, CA 91730 <br />P. 909.259.9971 | F. 909.944.8409 <br />www.AmorArch.com <br />WEST COAST | CENTRAL | EAST COAST <br />SHEETS BEARING THIS SEAL AND WET SIGNATURE <br />ARE AUTHENTICATED. RESPONSIBILITY FOR ALL <br />OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS <br />ARE DISCLAIMED. <br />TE <br />STA RN <br />FOAOCFLI <br />AI <br />LICENSED ARCHITECTWILLIAA.AMOR <br />DATE <br />8/31/2027 <br />M <br />C - 24421 <br />RENEWAL <br />DATE SIGNED: 10/03/2025 <br />1 1/24/25 PLAN CHECK CORRECTIONS <br />2 4/1/25 PLAN CHECK CORRECTIONS <br />3 5/2/25 PLAN CHECK CORRECTIONS <br />4 10/3/25 CHANGE BULLETIN <br />SCALECOUNTER COVED BASE 3/4" = 1'-0" <br />TILE BASE <br />COUNTER/ CABINET <br />3/8" MIN. <br />(TYP.) <br />FLOOR TILE <br />3/8" RADIUS BASE COVE4" <br />MI <br />N <br />COUNTER BASE <br />SCALEWALL COVED BASE 3/4" = 1'-0" <br />TILE BASE <br />3/8" MIN. <br />(TYP.) <br />FLOOR TILE <br />3/8" RADIUS BASE COVE <br />6" <br />GYPSUM BOARD <br />(INTERIOR WALL) <br />SCALE <br />WALL MOUNT BRACKET <br />PANEL BRACKET <br />3'-7 1/2" <br />1'-3 3/4"1'-0"1'-3 3/4" <br />N.T.S. <br />9" <br />1' <br />- <br />4 <br />" <br />10 <br />" <br />1' <br />- <br />3 <br />" <br />3" <br />7 1/2" <br />MONITOR BRACKET DETAIL (SIDE AND REAR) <br />3/4" = 1'-0" <br />SCALESELF-SERVE COUNTER ELEVATION <br />FINISH ENTIRE WALL INCLUDING PAINTING <br />PRIOR TO INSTALLATION OF MILL WORK <br />3/4" PLYWOOD FACING <br />W/ PLASTIC LAM. <br />WOOD PANEL FINISH <br />1/2" PLYWOOD CABINET FLUSH <br />MOUNTED DOORS W/ LAM. <br />WOOD PANEL FINISH W/ (3) <br />STAINLESS STEEL, WIRE <br />PULLS AND PIANO HINGES, (2) <br />PER DOOR <br />4" <br />8'-0" (VERIFY IN FIELD) <br />PROVIDE WOOD BRACE <br />CENTER LINE OF COUNTER SS-1 SOLID SURFACE <br />COUNTER-TOP, WITH <br />BACK-SPLASH TO MATCH <br />2' <br />- <br />1 <br />0 <br />" <br /> <br />M <br />A <br />X <br />. <br />48 <br />" <br /> <br /> <br />M <br />A <br />X <br />. <br />TO <br /> <br />C <br />O <br />N <br />T <br />R <br />O <br />L <br /> <br />A <br />C <br />C <br />E <br />S <br />S <br />STAINLESS STEEL LEG <br />COVED BASE w/ <br />3/8" RAD. BEYOND <br />PROTECT <br />SYRUP LINES <br />FROM TRUSS <br />ANGLE <br />BUNDLED <br />SYRUP LINES & <br />FILTERED <br />WATER LINE <br />OPTIONAL <br />INSTALLATION <br />1" WIDE GALV. <br />STRAPS @ EA. <br />TRUSS (MIN.6'-0") <br />BOTTOM CHORD <br />OF ROOF TRUSS <br />NOTE: <br />SYRUP LINE BUNDLE (OWNER <br />FURNISHED, AND INSTALLED) <br />6" = 1'-0" <br />SCALESYRUP LINESSCALEWALL & FLOOR JOINT @ <br />RESTROOM 3" = 1'-0" <br />SCHLUTER DILEX AHK ACGB <br />(BRUSHED CHROME) OR EQUAL <br />IN 3/8" MIN. RADIUS COVING <br />TILES, SEE FINISH SCHEDULE <br />1/8" SANDED OR EPOXY GROUT <br />ON WALL AND FLOOR. SEE FINISH <br />SCHEDULE <br />BONDED WATERPROOFING <br />MEMBRANE <br />CEMENTITIOUS <br />BOND COAT <br />2' <br />- <br />0 <br />" <br /> <br />M <br />I <br />N <br />. <br />3 <br />48 <br />15 <br />1417 <br />16 <br />12 <br />16 <br />18 TYP. INTERIOR WALL 1 1/2" = 1'-0" <br />SCALE <br />SEE RCP <br />CEILING HT. <br />SUSPENDED T-BAR CEILING <br />CONCRETE SLAB <br />BOTTOM ROOF STRUCTURE <br />CONT. 18GA. BOTTOM <br />TRACK w/ .145" x 1 1/4" MIN. <br />HILTI FASTENERS @ 16" <br />O.C. MAX. <br />(ICC ESR 1663) <br />- <br />16 <br />20 GA. SLOTTED SLIP <br />TRACK <br />1/ <br />2 <br />" <br />16GA. SLOTTED TOP CHANNEL TRACK <br />w/ (2) #10 TEX SCREWS AT 16" O.C. <br />6" <br /> <br />T <br />Y <br />P <br />. <br />1' <br />- <br />6 <br />" <br />DU <br />R <br />O <br />C <br />K <br />20 GA. 4" OR 6" METAL STUDS @ <br />16" O.C. SEE PLAN <br />5/8" TYPE "X" GYPSUM BOARD <br />·6" ABOVE LAY-IN CEILINGS, <br />·END AT GYP. BOARD CEILINGS <br />·FULL HEIGHT AT OPEN CEILINGS <br />A8.2 <br />5 <br />WALL BASE DETAIL 3" = 1'-0" <br />SCALE <br />SCHED. WALL <br />SEE WALL TYPES <br />00_WALL BASE_ <br />(E) CONCRETE SLAB <br />FINISH PER <br />SCHEDULE <br />CONTINUOUS METAL <br />BOTTOM TRACK w/ .145" <br />x 1 1/4" MIN. HILTI X-U <br />FASTENERS @ 16" O.C. <br />MAX. ESR 2269, LARR <br />25675 <br />KITCHEN <br />4" <br />1/2" CONTINUOUS <br />SEALANT <br />6" <br />SCHEDULED WALL <br />BASE SEE FINISH <br />FLOOR PLAN FOR <br />SPECS. <br />SCHEDULED BASE, <br />SEE FINISH FLOOR <br />PLAN FOR SPECS. <br />FRP <br />4 <br />4