NO <br />PA <br />R <br />K <br />I <br />N <br />G <br />EV <br />EV <br />EV <br />SECONDARY CONDUIT WITH PULL STRINGS TO UTILITY POWER <br />COMPANY TRANSFORMER <br />(VERIFY AND COORDINATE WITH SCE DESIGN FOR <br />REQUIREMENTS AND DETAILS) <br />2" EMPTY CONDUIT WITH PULL <br />STRING TO TELECOM <br />P.D.C.(VERIFY AND <br />COORDINATE) <br />'MDB' <br />1" C TO D.T. <br />WINDOW <br />1"C TO 'C' <br />J <br />J <br />MENU BOARD <br />AND SPEAKER <br />1"C TO 'C' <br />J <br />PRE-ORDER <br />BOARD <br />DT SIGN J <br />1"C, PROVIDE PULL STRING <br />(TYP. FOR PARKING LOT <br />LIGHTING AND DT SIGN CIRCUITS) <br />HP-3 <br />'F' <br />'F' <br />'F' <br />'F''F' <br />'F' <br />'F''F' <br />'F' <br />'F''F' <br />'F' <br />SITE DEVELOPMENT <br />UNDER SEPARATE PERMIT <br />HP-1 - (2#10 + #12 GND. CU) <br />PANEL 'B' <br />PANEL 'HP' <br />B-70 <br />HP-12,14 <br />B-84 <br />HP-8,10 <br />B-78 <br />B-72 <br />HP-4,6 <br />1.REFER TO E0.1 FOR ADDITIONAL GENERAL NOTES. <br />2.FIELD VERIFY EXACT LOCATION & ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL <br />CONTRACTOR PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. <br />3.ALL CONDUIT FOR THE CAT5 (TELEPHONE) SHALL BE EMT - NO FLEX CONDUIT. <br />4.COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD <br />SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY <br />LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE. <br />5.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR ALL COMMUNICATION WIRING. ALL CABLING SHALL BE BLUE <br />PLENUM RATED CAT5e. ALL CABLE & TERMINATION SHALL BE TESTED & LABELED AT BOTH ENDS. THE <br />ELECTRICAL CONTRACTOR SHALL TERMINATE ALL WIRING AT OUTLET LOCATIONS ON PLANS & CONNECT <br />ALL WIRING TO THE PATCH PANEL FOR ALL COMMUNICATIONS. THE OWNER WILL CONNECT PATCH PANEL <br />TO SERVER. <br />6.ALL COMMUNICATION OUTLETS SHALL HAVE A 1" CONDUIT STUB UP TO ACCESSIBLE CEILING SPACE FOR <br />DATA WIRING. PROVIDE INSULATED BUSHING AT EACH CONDUIT END. VERIFY EXACT LOCATION WITH <br />ARCHITECT PRIOR TO INSTALLATION. CONNECT ALL CABLES INTO IT SPACE. <br />7.ANY BRANCH CIRCUIT THAT SERVE NEW AIR COMPRESSORS, SHALL HAVE A "FULL SIZED" NEUTRAL <br />CONDUCTOR (MATCHING THE CONDUCTOR SIZE OF THE CURRENT CARRYING CONDUCTORS INSTALLED). <br />8.ALL UNDERGROUND CONDUITS SHALL BE INSTALLED IN ACCORDANCE WITH N.E.C. 300.5. <br />9.ANY PROPOSED TRENCHING FOR ELECTRICAL CONDUITS SHOWN PLANS SHALL BE CONSIDERED AS <br />SUGGESTED TRENCH ROUTING - CONTRACTOR TO ADJUST AS REQUIRED DUE TO SITE CONDITIONS. <br />COORDINATE ROUTING OF ALL UNDERGROUND CONDUITS WITH YOSHINOYA'S CONSTRUCTION MANAGER <br />PRIOR TO TRENCHING. <br />10.RECEPTACLES SHALL BE PROTECTED W/ GFCI DEVICES (RECEPTACLE OR BREAKER) CONTRACTOR TO <br />PROVIDE LOWEST COST SOLUTION. THIS IS TO BE DETERMINED AND VERIFIED BY ELECTRICAL <br />CONTRACTOR. AS REQUIRED BY CURRENT ADOPTED NEC CODE & ANY LOCAL AMENDMENTS . <br />EL <br />E <br />C <br />T <br />R <br />I <br />C <br />A <br />L <br /> <br />S <br />I <br />T <br />E <br /> <br />P <br />L <br />A <br />N <br />E1.1 <br />GENERAL NOTES (AS APPLICABLE) <br />S H E E T N U M B E R <br />A2641 <br />Pl <br />o <br />t <br />t <br />e <br />d <br />: <br /> <br />10 <br />/ <br />7 <br />/ <br />2 <br />0 <br />2 <br />5 <br /> <br />3 <br />: <br />5 <br />2 <br /> <br />A <br />M <br /> ( <br />me <br />p <br />- <br />1 <br />) <br /> <br />F <br />i <br />l <br />e <br />: <br /> <br />be <br />t <br />t <br />e <br />r <br /> <br />b <br />u <br />z <br />z <br /> <br />s <br />a <br />n <br />t <br />a <br /> <br />a <br />n <br />a <br /> <br />c <br />a <br />_ <br />e <br />l <br />e <br />c <br />t <br />r <br />i <br />c <br />a <br />l <br /> <br />s <br />e <br />t <br />. <br />d <br />w <br />g <br />PROJECT NUMBER <br />2024.06.27 <br />DATE <br />R E V I S I O N S <br />S T A M P <br />SHEETS BEARING THIS SEAL AND WET SIGNATURE <br />ARE AUTHENTICATED. RESPONSIBILITY FOR ALL <br />OLDER PLANS, SPECIFICATIONS OR INSTRUMENTS <br />ARE DISCLAIMED. <br />P <br />R <br /> <br />O <br /> <br />J <br /> <br />E <br /> <br />C <br /> <br />T <br />L <br />O <br /> <br />C <br /> <br />A <br /> <br />T <br /> <br />I <br /> <br />O <br /> <br />N <br />C O N S U L T A N T <br />S <br />H <br /> <br />E <br /> <br />E <br /> <br />T <br /> <br /> <br /> <br />T <br /> <br />I <br /> <br />T <br /> <br />L <br /> <br />E <br />C COPYRIGHT 2024 - DESIGNS, DRAWINGS AND SPECIFICATIONS ARE INSTRUMENTS OF SERVICE AND ARE THE PROPERTY OF THE DESIGN PROFESSIONAL. REPRODUCTION PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGN PROFESSIONAL. <br />16 <br />0 <br />1 <br /> <br />N <br /> <br />B <br />R <br />I <br />S <br />T <br />O <br />L <br /> <br />S <br />T <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />Kevin MacDonald <br />801 University Avenue <br />San Diego, CA 92103 <br />kevin.macdonald@betterbuzzcoffee.com <br />9431 HAVEN AVENUE, SUITE 212 <br />RANCHO CUCAMONGA, CA 91730 <br />P. 909.259.9971 | F. 909.944.8409 <br />www.AmorArch.com <br />WEST COAST | CENTRAL | EAST COAST <br />909-997-0905 <br />CARLOS RIVAS <br />carlos@rivasdesignconsultants.com <br />MECHANICAL I ELECTRICAL I PLUMBING <br />TE <br />STA RNFOAOCFLI <br />AI <br />LICENSED ARCHITECTWILLIAA.AMOR <br />DATE <br />8/31/2027 <br />M <br />C - 24421 <br />RENEWAL <br />2025-02-05 PLAN CHECK CORRECTIONS1 <br />2025-04-07 PLAN CHECK CORRECTIONS2 <br />2025-10-06 ELECTRICAL CLARIFICATIONS3 <br />ELECTRICAL SITE PLAN 1SCALE <br />1" = 10'-0" <br />N <br />KEYNOTESKEYNOTES <br />3 <br />3