Laserfiche WebLink
ADDRESS:CONTRACTOR:EQUIPMENT:DATE REV 0 <br />KW (DC)KW (AC)DELTA M4-TL-US PV6 <br />GAF ENERGY TLS-2 LABELS <br />BY:Aldortega <br />10/21/2025 <br />Lydia Pearson GAF Energy LLC (CA)1.71 <br />(30)5981 Optical Ct2026 Kemper Avenue 973-628-3411 <br />4 (1) <br />B #1062345 C-10 San Jose CA 95138Santa Ana CA 92705 <br />LABEL 1 <br />AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT, AND <br />DEVICE WHERE ENERGIZED UNGROUNDED CONDUCTORS <br />MAY BE EXPOSED DURING SERVICE. NEC. 690.35(F) <br />LABEL 2 <br />FOR PV DISCONNECTING MEANS WHERE ALL TERMINALS OF <br />THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE <br />OPEN POSITION.NEC 690.17(E), NEC 705.22 <br />LABEL 3 <br />AT POINT OF INTERCONNECTION, MARKED AT AC <br />DISCONNECTING MEANS.NEC 690.54, NEC 690.13 (B) <br />LABEL 4 <br />AT POINT OF INTERCONNECTION FOR EQUIPMENT <br />CONTAINING OVERCURRENT DEVICES IN CIRCUTS SUPPLYING <br />POWER TO A BUSBAR OR CONDUCTOR SUPPLIED FROM <br />MULTIPLE SOURCES, EACHSERVICE EQUIPMENT AND ALL <br />ELECTRIC POWER PRODUCTION SOURCE LOCATIONS.NEC <br />705.12(D)(3 <br />LABEL 6 <br />PLACED ADJACENT TO THE BACK-FED BREAKER FROM THE <br />INVERTER IF TIE IN CONSISTS OF LOAD SIDE CONNECTION TO <br />BUSBAR.NEC 705.12(D)(2)(3)(B) <br />LABEL 7 <br />SIGN LOCATED AT UTILITY SERVICE <br />EQUIPMENT.NEC 690.56(C) <br />LABEL 8 <br />SIGN LOCATED AT PV COMBINER PANEL. NEC <br />705.12(B)(2)(3)(C) <br />240 <br />16 <br />LABELING NOTES: <br />1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS. ELECTRICIAN <br />TO DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL <br />CODES AND MAKE APPROPRIATE ADJUSTMENTS. <br />2. LABELING REQUIREMENTS BASED ON THE (NFPA 70) 2017 National Electric Code <br />3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. <br />4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT <br />INVOLVED [NEC 110.21] <br />5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8", WHITE ON RED BACKGROUND; <br />REFLECTIVE, AND PERMANENTLY AFFIXED [IFC 605.11.1.1] <br />LABEL 5 <br />AT DIRECT-CURRENT EXPOSED RACEWAYS, CABLE <br />TRAYS, COVERS AND ENCLOSURES OF JUNCTION <br />BOXES, AND OTHER WIRING METHODS; SPACED AT <br />MAXIMUM 10FT SECTION OR WHERE SEPARATED BY <br />ENCLOSURES, WALLS, PARTITIONS, CEILINGS, OR <br />FLOORS.NEC 690.31(G)(3&4) <br />LABEL 9 -INVERTER <br />AT PV DISCONNECTING MEANS. TO BE USED IF NEC 2014 <br />APPLIES. NEC 690.53 <br />LABEL 10 -INVERTER 1 <br />AT PV DISCONNECTING MEANS. TO BE USED IF NEC 2017 <br />APPLIES. NEC 690.53 <br />172.4 <br />6.63 <br />380 <br />6.30 <br />172.4 <br />6.63 <br />LABEL 12 <br />SIGN LOCATED AT INVERTER RAPID SHUTDOWN <br />SWITCH. NEC 690.56(C)(2) <br />LABEL 11 <br />FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY <br />AND CONDUCTORS LEAVING THE ARRAY NEC <br />690.56(C)(1). CEC 690.56(C)(1)(A) <br />RAPID SHUTDOWN SWITCH FOR <br />SOLAR PV SYSTEM <br />INVERTER