Laserfiche WebLink
4' <br />17 <br />' <br />11' <br />3'57' <br />12 <br />0 <br />' <br />12 <br />0 <br />' <br />57' <br />16' <br />1621 S DIAMOND ST <br />UNIT 2 SANTA ANA, CA 92704 <br />DIAMOND ADU PV-1 <br />DATE: 11/10/2025 REV B <br />AHJ: <br />APN: 40824215 <br />SANTA ANA CITYSCALE: <br />SHEET SIZE: 11" x 17" <br />TEMPLATE V2.0 <br />PREPARED BY: <br />HIGH LINE DESIGNS <br />SCOTT TOYAMA <br />HUY THIEU NGUYEN <br />C10 #833971 1/16" = 1'-0" <br />COVER <br />SHEET <br />SITE PLAN <br />·(08) LONGI LR5-54HPB-400M MODULES <br />·(08) TIGO TS4-A-F RAPID SHUTDOWN <br />·(01) GROWATT MIN 6000TL-XH-US (240V) INVERTER <br />·(01) NON-FUSED AC DISCONNECT <br />ALL WORK TO COMPLY WITH: <br />·2022 CALIFORNIA ELECTRICAL CODE <br />·2022 CALIFORNIA RESIDENTIAL CODE <br />·2022 CALIFORNIA FIRE CODE <br />·2022 CALIFORNIA BUILDING CODE <br />TABLE OF CONTENTS <br />PV-1 COVER SHEET <br />PV-2 ROOF PLAN & MODULES <br />PV-2A STRINGING PAGE <br />PV-3+ ATTACHMENT DETAILS <br />PV-4 SINGLE-LINE DIAGRAM <br />PV-4A ELECTRICAL CALCULATIONS <br />PV-5 LABELS & PLACARD <br />PV-6+ EQUIPMENT DATASHEETS <br />SITE DETAILS <br />ASHRAE MIN TEMP <br />ASHRAE 2% HIGH TEMP <br />BUILDING OCCUPANCY <br />TYPE OF CONSTRUCTION <br />SPRINKLERS SYSTEM PER NFPA 13D <br /># OF STORIES <br />WIND SPEED (ASCE 7-16) <br />WIND EXPOSURE <br />RISK CATEGORY <br />GROUND SNOW LOAD <br />SQUARE FOOTAGE <br />UTILITY <br />2°C <br />31°C <br />R-3 <br />V-B <br />NO <br />1 <br />95 MPH <br />B <br />II <br />0 PSF <br />1500 SQ FT <br />SCE <br />VICINITY MAP <br />GOVERNING CODES <br />TOTAL PV SIZE: 3.200 KW DC, 2.902 KW CEC AC <br />SCOPE OF WORK <br />INSTALL A ROOF-MOUNTED PV SYSTEM: <br />GENERAL NOTES <br />·ALL WORK SHALL CONFORM TO APPLICABLE BUILDING, <br />ELECTRICAL CODE AND ANY LOCALLY ADOPTED ORDINANCES. <br />·DRAWINGS ARE DIAGRAMMATIC, SITE CONDITIONS SHALL <br />PREVAIL. IF NO SCALE IS GIVEN, DRAWINGS ARE NOT TO <br />SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY THE <br />CONTRACTOR IN THE FIELD UPON COMMENCEMENT OF <br />CONSTRUCTION. <br />·ALL CONDUIT AND WIRE RUNS ARE DIAGRAMMATIC, SUBJECT <br />TO FIELD CONDITIONS ROUTING OF RACEWAYS SHALL BE <br />FINALIZED BY THE CONTRACTOR. IF THE DISTANCES FOR WIRE <br />RUNS ARE DIFFERENT THAN AS SHOWN, THE CONTRACTOR <br />SHALL NOTIFY THE DESIGN TEAM TO VALIDATE THE WIRE SIZE. <br />·ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A <br />RECOGNIZED TESTING LABORATORY AND INSTALLED PER THE <br />LISTING AND MANUFACTURER'S REQUIREMENTS. <br />·ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE <br />WITH REQUIRED ACCESS AND WORKING CLEARANCES <br />PER CEC ARTICLE 110. <br />·ALL NEW MAIN SERVICE PANELS AND SUBPANELS WILL HAVE <br />APPROPRIATE FIELD IDENTIFICATION PER CEC 408.4. <br />·ALL EQUIPMENT WILL BE INSTALLED WHERE IT IS NOT EXPOSED <br />TO PHYSICAL DAMAGE PER CEC 110.27(B) <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />S DIAMOND ST <br />FRONT OF HOUSE <br />W <br />P <br />O <br />M <br />O <br />N <br />A <br /> <br />S <br />T <br />STARS CONSTRUCTION SERVICES INC <br />6022 WESTERN AVE <br />BUENA PARK, CA 90621 <br />714.262.3929