My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10177791_2102 N. TUSTIN - Plan (2)
PBA
>
Building
>
Plans
>
T
>
Tustin Ave
>
2102 N Tustin Ave
>
10177791_2102 N. TUSTIN - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2026 3:33:39 AM
Creation date
10/25/2020 9:41:16 PM
Metadata
Fields
Template:
Plan
Permit Number
10177791
Full Address
2102 N Tustin Ave
Street Number
2102
Street Direction
N
Street Name
Tustin
Street Suffix
Ave
Fully Linked
True
Document Relationships
10177791 - Permit
(Permit - Plan)
Path:
\Building\Permits\T\Tustin Ave\2102 N Tustin Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
338
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
12. <br />13. <br />11. <br />16. <br />17. <br />Page 3 of 4 <br />Reference each fire resistive assembly to a CBC Chapter 7, Table and Item number: <br />-Wall6 <br />-Ge#ings <br />-Ce|wmAS <br />Provide fire blocking in concealed spaces of stud walls and partitions, including furred spaces at the <br />ceiling and floor level and at 10 ft. intervals both vertical and horizontal. <br />Fire blocking. In combustible construction, fire blocking shall bc installed to cut off concealed draft <br />openings (both vertical and horizontal) and shall form an effective barrier between floors, between a top <br />story and a roof or attic space. Fire blocking shall be installed in the locations specified in CBC. <br />Provide complete details on the drawings showing compliance with CBC Section 1405 requirements for <br />veneer construction. See Detail 5/A9.3, and Details 1/A9.3, 2/A9.3, 3/A9.3,4/A9.3 and 7/A9.3 that refer <br />to Detail 5/A9.3. <br />The width of the level area on the side to which the door swings shall extend 21" past the strike edge of <br />the door for exterior doors. Show compliance for doors # N10, N11, N12 & Nl 3. <br />Note type of safety glazing complying with CBC Section 2106 for glazing in fixed or operable panels <br />adjacent to a door wherc the nearest exposed cdgc of the glazing is within a 21" arc of either vertical <br />edge of the door in a closed position and where the bottom exposed edge of the glazing is less than 60" <br />above the walking surface. <br />18. Show/note ventilation requirements on the plans in accordance with the CBC and California <br />Mechanical Code (CMC) requirements for each type of use. <br />Noteendfawings; <br />All enclosed portions of buildings customarily occupied by human beings shall be provided with natural <br />ventilation by means of openable exterior openings readily controllable by building occupants, with an area not <br />less than 1% of the floor area being ventilated. CBC Section 1203 and 2010 California Mechanical Code <br />-Sestien-402- <br />Provide mechanical ventilation for each orea/room in accordance with the 2010 California Mechanical Code. <br />his building is subject to the State of California Energy Conservation Regulations: <br />- The permit applicant shall be responsible for obtaining an energy plan check from a consultant who is <br />qualified to perform an energy efficiency analysis in accordance with the California Code of Regulations <br />(CCR,) Title 24, Par 6, 2010 California Energy Code. The plan check consultant must sign documentation <br />certifying that a thorough, competent review has been performed on behalf of the Enforcement Agency. <br />- The corrected/final ARCHITECTURAL drawings shall have the required energy efficiency compliance <br />documentation with completed signature blocks filed on the plans. The same information may be copied on <br />the Electrical Plans for the Electrical Plan Checker. <br />- Provide cool roofing as required by 2008 Energy Standards. <br />- The energy plan check consultant must complete the attached "Energy Conservation Plan Check Consultant <br />Qualification Statement." Please see the Energy Envelope Analysis with Third Party Review included with the <br />3Rx.,
The URL can be used to link to this page
Your browser does not support the video tag.