CERTIFICATE OF COMPLIANCE (Part 2 of 3)ENV-1 C <br />AND FIELD INSPECTION ENERGY CHECKLIST <br />Project Name Date <br />Catalina Commercial Center 3/27/2013 <br />ROOFING PRODUCT (COOL ROOFS) <br />(Note if the roofing product is not CRRC certified, this compliance approach cannot be used). Go to Overall Envelope Approach or <br />Performance Approach. <br />CHECK APPLICABLE BOX BELOW IF EXEMPT FROM ™E ROOFING PRODUCT"COOL ROOF" REQUIREMENTS:Pass Fail 1 N/A <br />O Roofing compliance [12! required in Climate Zones 1 and16 with a Low-Sloped. 2:12 pitch or less.000 <br />O Roofing compliance nfli required in Climate Zone 1 with a Steep-Sloped with less than 5 lb/ff. Greater than 2:12 pitch. 0 0 0 <br />¤ Low-sloped Wood framed roofs in Climate Zones 3 and 5 are exempted, solar reflectance and thermal emittance or <br />SRI that have a U-factor of 0.039 or lower. See Opaque Surface Details roof assembly, Column H of ENV-2C. <br />¤ Low-sloped Metal building roofs in Climate Zone 3 and 5 are exempted, solar relectance and thermal emittance or SRI <br />that have a U-factor of 0.048 or lower. See Opaque Surface Details roof assembly below, Column H of ENV-2C. <br />¤ The roof area covered by building integrated photovoltaic panels and building integrated solar thermal panels are <br />exempted. Solar reflectance and thermal emittance or SRI, see spreadsheet calculator at www.enerqv.ca.gov/title24/ <br />¤ Roof constructions that have thermal mass over the roof membrane with a weight of at least 25 lb/fr' are exempt from <br />the Cool Roof criteria below. <br />¤ High-rise residential buildings and hotels and moteIs with low-sloped roofs in Climate Zones 1 through 9,12 and 16 are <br />exempted from the low-sloped roofing criteria. <br />O 0 <br />0 0 <br />CIO <br />0 0 <br />0 0 <br />1. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. <br />CRRC Product ID Roof Slope Product Weight Product Aged Solar Thermal <br />Numbe/s 2:12 >2:12 <51bnf 2 5lb/ft2 Type2 Reflectance3 Emmitance SR'5 Pass <br />R-30 Roof GAFGLA. O 0 0 04 0.75 0.85 0 <br />0 moo 04 0 <br />0 0 0 0 04 0 <br />0 0 0 0 04 0 <br />0 0 0 0 04 0 <br />0 0 0 0 04 0 <br />1. The CRRC Product ID Number can be obtained from the Cool Roof Rating Council's Rated Product Directory at <br />www.coolroofs.ora/products/search.php <br />2. Indicate the type of product is being used for the roof top, i.e. single-ply roof, asphalt roof, metal roof, etc. <br />3. If the Aged Reflectance is not available in the Cool Roof Rating Council's Rated Product Directory then use the Initial Reflectance value from the <br />same directory and use the equation (0.2+0.7(pinitia] - 0-2) to obtain a calculated aged value. Where p is the Initial Solar Reflectance from the Cool <br />Roof Rating Council's Rated Product Directory. <br />4. Check box if the Aged Reflectance is a calculated value using the equation above. <br />5. The SRI value needs to be calculated from a spreadsheet calculator at html/www.enerav.ca.gov/title24/ <br />6. If Fail then describe on this page of the Inspection Checklist Form and take appropriate action to correct. Verify building plans if necessary. <br />To apply Liquid Field Applied Coatings, the coating must be applied across the entire roof surface and meet the dry mil thickness or coverage <br />recommended by the coatings manufacturer and meet minimum performance requirements listed in §118(i)4. Select the applicable coating: <br />¤ Aluminum-Pigmented Asphalt Roof Coating ¤Cement-Based Roof Coating ¤Other <br />Discrepancies: <br />EnerqyPro 5.1 by EnemySoft User Number: 6055 RunCode: 2013-03-27T09:46:35 ID: CO7429 Page 7 of 14