Laserfiche WebLink
Savings ByDesign UTILITY INCENTIVE WORKSHEET UTIL-1 <br />Project Name <br />Catalina Commercial Center <br />Step 1 ANNUAL TDV ENERGY USE (kBtu/sqft-yr) <br />ENERGY COMPONENT Standard Proposed Marain <br />- <br />Space Heating 58.63 47.99 10.65 <br />Date <br />3/27/2013 <br />Step 2 PERCENT BELOW TITLE 24 <br />Adjusted TDV Energy Use <br />(Excludes Process Energy) <br />Space Cooling 151.10 133.13 17.98 <br />Indoor Fans 53.96 52.29 1.68 <br />Standard Proposed <br />Design Design Margin <br />370.16 -339.86 =30.30 <br />Heat Rejection 0.00 0.00 0.00 <br />0.00 0.00 0.00Pumps <br />Domestic Hot Water 0.00 0.00 0.00 <br />Standard %Below <br />Margin Design Title 24* <br />30.30 /370.16 =8.2 % <br />Lighting Incentive Eligibility Yes <br />42.06 42.06 0.00 <br />Receptacle 64.40 64.40 0.00 Owner Incentive (>=1056) O <br />Process 0.00 1 0.00 0.00 <br />Process Lighting 0.00 1 0.00 0.00 <br />TOTALS:370.16 339.86 30.30 Conditioned Floor Area =5,580.0 fF sq. ft. <br />Step 3 ANNUAL S TE ENERGY USE <br />Average 2pm - 5pm Standard Proposed Margin <br />Peak Demand (kW)36.4 33.4 3.0 <br />The values shown here are based upon the results of an <br />EnergyPro Compliance energy analysis that uses Title 24 <br />profiles as specified in the Alternative Calculation Method <br />manual. <br />Standard Proposed Margin <br />ENERGY COMPONENT Electricity Natural Gas Electricity Natural Gas Electricity Natural Gas <br />(kWh)(therms)(kWh)(therms)(kWh)(therms) <br />Space Heating 0 1,899 0 1,553 0 346 <br />Space Cooling 25,197 0 22,241 0 2,956 0 <br />Indoor Fans 13,482 0 13,064 0 419 0 <br />Heat Rejection 0 0 0 0 0 0 <br />Pumps 0 0 0 0 0 0 <br />Domestic Hot Water 0 0 0 0 0 0 <br />Lighting 10,281 0 10,281 0 0 0 <br />Receptacle 16,382 0 16,382 0 0 0 <br />Process 0 0 0 0 0 0 <br />Process Lighting 0 0 0 0 0 0 <br />Step 4 <br />TOTALS:65,343 1,899 61,968 1,553 3,375 '346 <br />POTENTIAL OWNER I VCENTIVE CALCULATION <br />% Below Title-24*Incentive Savings <br />(from step 2)Rate (from Step 3)Subtotal <br />Electricity (kWh) n/a| · n/a x n/a =n/a <br />SOUTHERN CALIFORNIA <br />E DISON Electricity (kW) <br />¢/kWh kWh <br />n/a x n/a =n/a <br />An ED/SON /NTERNAT/ONAL® Company $/kW kW <br />Natural Gas =n/a X rda =n/a <br />¢/therm therrn <br />Owner Incentive n/a <br />Potential incentives indicated on this report are available only through the Whole Building Approach Element of the <br />Savings By Design Program for new construction and are NOT GUARANTEED. Projects MUST receive prior, written <br />approval from The Utility during conceptual or early design development and must meet all other program requirements <br />to qualify. Potential incentives are subject to program limitations based upon the incremental cost of the measures. <br />*% Below in this equation is limited to 30%. <br />EnergyPro 5.1.7.6 by EnergySoft User Number: 6055 RunCode: 2013-03-27T09:46:35 ID: CO7429 Page 10 of 14