20164373 - Permit
PBA
>
Building
>
Permits
>
C
>
Corta Dr
>
622 S Corta Dr
>
20164373 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/28/2021 11:07:59 AM
Creation date
7/28/2021 11:07:58 AM
Metadata
Fields
Template:
Permit
Permit Number
20164373
Full Address
622 S Corta Dr
Permit ID
235066
Master ID Number
2017-139302
Project Name
Miscellaneous Counter1 Permit
Street Number
000622
Street Direction
S
Street Name
Corta
Street Suffix
Dr
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
10/11/2017
Issued Date
10/11/2017
Finalized Date
12/4/2017
Flood Zone
A-0602320256J
Description of Work
Install new 2.8 kw roof mounted solar PV system. (10 panels) ALL FEES PAID ON 10194454
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Notes for One-Line Standard Electrical <br />Diagram for Single-Phase PV Systems <br />cdtrcld N.m <br />Ad6r.nd Pno. <br />051 P6 r176 L.rC46 100a233 <br />Site Name: s6r Rosd,,r" <br />Site AddreSS: 6:,? s c6'. or s'r. &E ca Erro{ <br />System AC Size: zrcz.w <br />"^^& RP <br />PV MODUtt RATINGS @ STC [Gurde Section 5) <br />r,rocnJLE MAKE RECOM <br />MoouLE MoDEL RCM -280-6MB-BB <br />MAx PowER-PorNT CURRENT (sp) 8.67 <br />MAx powER-potNT VoLTAGE (v*p) 32.5 <br />oPENcrRcurr voLTAGE (v6) ,39.2 <br />sHoRT,crRcurr CURRENT (s) 8.99 <br />MAX SERIES FUSE (OCPD) '15 A <br />MAxrMuM PowER (PMA) 280 W <br />MAx VoLTAGE (TYP 6oovd) 1 000 V <br />vOC TEMPCOEFF (mVfCO or %rCD . <br />-.32 <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />NOTES FOR ALL ORAWIJGS <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIOML ELECTRICAL COD€. REFERENCES <br />sHovvN AS (wEC XXXXX' <br />stGNs-sEt GUtDt stcTroN 7 <br />SIGN FOR DC DISCONNTCT <br />No srgn necessary sinct 690 51 <br />marking on PV module covers <br />needed information <br />I{OTES FOR ARRAY CIRCUIT WRING (Grrde S6cton 6 and 8 and App€ndr E) <br />1 ) LOWEST EXPECI AMBIENT TEMPERATURE BASED ON ASHRAE MINIIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCAION N,IOST SIMILAR TO <br />INSTALLATION LOCATION LOWEST EXPECTED AMBIENT TEMP 2 'C <br />2 ) HIGHEST CONTINUOUS AiJBIENT TEMPERATURE BASED ON ASHRAE HICHEST <br />MONTH 2% DRY BULE TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION HIGHEST CONTINTJOUS TEMPERATURE -].1-"C <br />2 ) 2M9 ASHRAE FUNDAMENTALS 2% OESIGN TEMPERATURES DO NOT EXCEED4rC tN THE UNTTED STATES (PALM SPRTNGS. CA rS 44 1"C) FORLESS TFAN9 <br />CURRENT'ARRYII']G CONCUCTORS IN ROOF-MOUNTED SUNLIT CONDUIT AT <br />LEAST O 5' ABOVE ROOF ANO USING THE OUTDOOR DESIGN TEMPERATURE OF <br />4TC OR LESS (ALL OF UNITED STATES). <br />a, 12 AWG,gdc CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WTH lsc OF 7 68 AMPS OR LESS WHEN PROTECTED BY A 12-A[rP OR SMALLER <br />FUSE <br />b) 1O AWG,gCfC CONDICTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WTH lsc OF I6 AMPS OR LESS WHEN PROTECTED BY A ls-AMP OR SMALLER <br />FUSE. <br />NOTES FOR INVERTER CIRCUITS (Gude Sec'll]n I and 9) <br />AC OUTPUTCURRENI <br />NOMINAL AC VOLTAGT <br />9.6 A <br />240 V <br />THIS PANEL FED BY MULTIPLE <br />souRcES (ulrLrTY AND SOLAR) <br />INVtRIER RAllNGs (6uid€ section 4l <br />INVERIER MAKE ENPHASE <br />NvrRTERMoorL lQ6-60-X-US <br />MAX DC VOLT RATING <br />MAX POWER @ ,tO"C <br />I.JOMINAL AC VOLTAGE <br />MAX AC CURRENT <br />i,AX OCPD RATIIIG <br />SIGN TOR INVERTTR OCPD AND AC <br />DlscoNNtcT !r ust D) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />48V <br />240 W <br />240 <br />0.96 A <br />2QA <br />1) IF UTILIW REOUIRES A VISIBLE.BREAK SWTCH. DoES THIS SWTCH MEET THE <br />REOUIREMENT? YESE l.lo tr fUA tr <br />2) IF GENERATION METER REOUIREO. DOES THIS METER SOCKET MEET THE <br />FEOUIREMENT" YES O I.IO tr I'JA E <br />3) SrZE PFIOTOVOLTATC POWER SOURCE (DC) CONOUCTORS AASED ON t\,tAX <br />CURRENT ON NEC 690 53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDII.lG TO ItNERTER <br />OCPD AMPERE RATING (Soe Guide Section 9) <br />5) ToTAL OF I t.,^ INVERTER OUTPUT CIRCUIT OcPOrs). oNE FOR EACH MICRO- <br />INVERTER CIFCUI]IDoES ToTAL SUPPLY BREAKERS iCiMPLY WTH 120% BUSaAR <br />ExcEPTloN lN 690 64(8)(zxa)? YESE Notr <br />o*rd3' EL D.te 10/10/'t7 <br />NOT ES FOR MICRO-INVERTER ELECTRICAI- DIACRAM <br />2 <br />F <br />c- <br />c <br />Icc.c-t:I <br />c- <br />c <br />F <br />e <br />= <br />F'
The URL can be used to link to this page
Your browser does not support the video tag.