My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179217_2800 N. MAIN 248 - Plan (2)
PBA
>
Building
>
Plans
>
M
>
Main St
>
2800 N Main St Unit# 248
>
10179217_2800 N. MAIN 248 - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2021 11:51:22 AM
Creation date
10/25/2020 9:43:15 PM
Metadata
Fields
Template:
Plan
Permit Number
10179217
Full Address
2800 N Main St Unit# 248
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
November 14, 2012 SIGN COMPONENTS MANUAL (SAM)122 <br />5. When used in a cord connected product, the need for conducting a leakage current test shall be considered in the end product. <br />6. When not marked for Dry and Damp Locations Only the power supply primary bracket shall be provided with min. 3.5 threads <br />and maximum 5 threads tapered for connection to liquid tight conduit fitting. If less than 3.5 threads, the liquid tight shall be <br />provided with watertight fitting Listed (QCRV) 1/2 inch, liquid tight conduit fittings. <br />7. The suitability of grounding connection shall be determined in the end-use product. <br />Class 2 power supply, Model 701680. <br />1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate <br />application. <br />2. These units are provided with a Class 105(A) insulation system. <br />3. The suitability of the input and output connections shall be determined in each end use application. <br />4. These power units are intended for dry or damp location use only. <br />5. Strain Relief on input lead construction and Impact Tests have not been investigated. <br />6. The polymeric enclosure of each unit has not been evaluated as ultimate enclosure. The flame class of polymeric enclosure of <br />each unit is V-2, and the necessity of additional fire barriers shall be determined in end product. <br />7. Multiple power supplies shall be spaced at least 25mm (1 in.) end to end or 102mm (4 in.) in other directions. If lesser spacings <br />are used, then the Temperature Test shall be conducted in the end use product. For reference the maximum enclosure (case) <br />temperature on the power supply was 90°C when tested at 58.4° ambient. <br />Class 2 power supply, Model 701680-MW. <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 <br />output. <br />2. The load powered by the Class 2 output of the power supplies rated at max 30 VDC or less are suitable for use in dry, damp and <br />wet locations. <br />3. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of endosure. <br />4. These products are provided with the following electrical ratings: <br />Input Output <br />Model I Vac A Hz Vdc A <br />701680-MW | 100-240 0.55 50/60 12 1.67 <br />5. These products shall be enclosed in the end product. <br />6. These power supplies are suitable for use in dry and damp locations. <br />Class 2 power supply, Model 701681. <br />1. The product shall be installed in compliance with the mounting, spacing, casualty, and segregation requirements of the ultimate <br />application. <br />2. These units are provided with a Class 105(A) insulation system. <br />3. Input leads are Style 1015, No. 18 AWG, rated VW-1, 600 V, 105°C. Output leads are Style 1430, No. 18 AWG, rated VW-1, <br />300 V, 105°C. The suitability of the input and output connections shall be determined in each end use application. <br />4. These power units are intended for dry or damp location use only. <br />5. Strain Relief and Impact Tests have not been investigated on input lead construction. The suitability of the endosure as ultimate <br />enclosure shall be determined in the end-use application. <br />6. The polymeric enclosure of each unit has not been evaluated as ultimate endosure. The flame class of the polymeric enclosure <br />is V-0 and the necessity of additional fire barriers shall be determined in end product. <br />7. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />Class 2 power supplies, Model 701495. <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of four Class 2 <br />outputs. <br />2. These power supplies are only suitable for use in dry, damp and wet locations. <br />3. In the end product, power supply spacing to other heat produdng components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />Class 2 power LED Lighting Strip, 701912-QQXXYYZZZ series, where QQ represents length, XX represents the LED color <br />temperature, YY represents configuration and ZZZ represents the LED drive current. <br />1. These products are only suitable for connection to a Class 2 power source, rated 24VDC. <br />2. These products have not been evaluated for use when connected to a power source that does not comply with Class 2 voltage <br />and energy limits and which is rated greater than 24VDC. <br />3. When units are connected to a Class 2 circuit, they are not to draw a total wattage of greater than the secondary or output rating <br />of the Class 2 supply. <br />4. These products are suitable for use in dry, damp and wet locations with supply sources rated class 2. <br />5. These products are not required to be enclosed or protected from the weather in the end product. <br />6. These products may be secured in place in the end product by any means available. <br />7. When these products are used in applications other than signs or outline lighting, the need to conduct a temperature test shall <br />be considered. <br />Class 2 "Dimming Control Knob" potentiometer, Model 701843. <br />1. These products are only suitable for connection to the output of a UL Listed or Recognized Class 2 power supply rated max 12 <br />VDC. <br />2. These products are suitable for use in dry and damp locations. <br />3. These products are suitable for factory wiring only. <br />4. These products are 1 Kohm potentiometers intended for connection to max 12 VDC Class 2 power supply that drops the voltage <br />to a 0-10 V signal to feed into the PWM dimmer. <br />SPARTECH PLASTICS E202184 <br />3454 N DETROIT ST <br />WARSAW, IN 46580 <br />Rigid sign enclosure systems, designated SunGard, Sungard Plus, PC-2000, DuraGard and PC-2000 Plus.
The URL can be used to link to this page
Your browser does not support the video tag.