My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179304_1408 W. 2ND - Plan (2)
PBA
>
Building
>
Plans
>
S
>
Second St
>
1408 W Second St
>
10179304_1408 W. 2ND - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:11 PM
Creation date
10/25/2020 9:43:26 PM
Metadata
Fields
Template:
Plan
Permit Number
10179304
Full Address
1408 W Second St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SOLARMOUNT Technical Datasheets :i: UNI RAC. <br />0-HILTI GROUP COMPANY <br />SolarMount Mid Clamp <br />Part No. 302101 C, 302101 D, 302103C, 302104D, <br />302105D, 3021060 <br />Bolt <br />Ciamp \ \\ <br />t <br />Beam .WIp--.1 i <br />Mid clamp material: One of the following extruded aluminum <br />alloys: 6005-T5, 6105-T5, 6061-T6 <br />Ultimate tensile: 38ksi, Yield: 35 ksi <br />Finish: Clear or Dark Anodized <br />Mid clamp weight: 0.050 lbs (23g) <br />Allowable and design loads are valid when components are <br />assembled according to authorized UNIRAC documents <br />Values represent the allowable and design load capacity of a single <br />mid clamp assembly when used with a SolarMount series beam to <br />retain a module in the direction indicated <br />Assemble mid clamp with one Unirac 1/1"-20 T-bolt and one W-20 <br />ASTM F594 serrated flange nut <br />Use anti-seize and tighten to 10 ft-lbs of torque <br />Resistance factors and safety factors are determined according to <br />part 1 section 9 of the 2005 Aluminum Design Manual and third- <br />party test results from an IAS accredited laboratory <br />1-00 DISTANCE -,- - -22#WEEN MODULB | <br />TE <br />Y <br />L.X <br />Dimensions specified in inches unless noted <br />Applied Load Average Allowable Safety Design Resistance <br />Direction Ultimate Load Factor,Load Factor, <br />lbs (N)lbs (N)FS lbs (N) ® <br />Tension, Y+2020 (8987)891 (3963)2.27 1348 (5994)0.667 <br />Transverse, Z.520 (2313)229 (1017)2.27 346 (1539)0.665 <br />Sliding, Xt 1194 (5312)490 (2179)2.44 741 (3295)0.620 <br />SolarMount End Clamp <br />Part No. 302001 C, 302002C, 3020020, 302003C, <br />3020030,302004C, 302004D, 302005C, 302005D, <br />302006C, 3020060,302007D, 302008C, 302008D, <br />302009C, 3020090, 302010C, 302011C, 302012C <br />Olt <br />>Rad Clamp <br />- Serrated <br />Flange Nut 11 <br />Y <br />L.x <br />• End clamp material: One of the following extruded aluminum <br />alloys: 6005-T5, 6105-T5, 6061-T6 <br />• Ultimate tensile: 38ksi, Yield: 35 ksi <br />· Finish: Clear or Dark Anodized <br />• End clamp weight: varies based on height: -0.058 lbs (26g) <br />· Allowable and design loads are valid when components are <br />assembled according to authorized UNIRAC documents <br />· Values represent the allowable and design load capacity of a single <br />, end clamp assembly when used with a SolarMount series beam to <br />retain a module in the direction indicated <br />Assemble with one Unirac 74"-20 T-bolt and one %"-20 ASTM F594 <br />serrated flange nut <br />Use anti-seize and tighten to 10 ft-lbs of torque <br />Resistance factors and safety factors are determined according to <br />part 1 section 9 of the 2005 Aluminum Design Manual and third- <br />party test results from an IAS accredited laboratory <br />Modules must be installed at least 1.5 in from either end of a beam <br />1241 <br />1.5 <br />4 MOOMUN 1 <br />HmeCT 1 <br />VAR;EIS 1 <br />,=El <br />Dimensions specified-#funches-unless-noted <br />Applied Load Average Allowable Safety Design Resistance <br />Direction Ultimate Load Factor,Loads Factor, <br />lbs (N)lbs (N)FS lbs (N) O <br />Tension, Y+1321 (5876)529 (2352)2.50 800 (3557)0.605 <br />Transverse, Zi 63 (279)14 (61)4.58 21 (92)0.330 <br />Sliding, Xi 142 (630)52 (231)2.72 79 (349)0.555
The URL can be used to link to this page
Your browser does not support the video tag.