My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10179304_1408 W. 2ND - Plan (2)
PBA
>
Building
>
Plans
>
S
>
Second St
>
1408 W Second St
>
10179304_1408 W. 2ND - Plan (2)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/2/2021 11:54:11 PM
Creation date
10/25/2020 9:43:26 PM
Metadata
Fields
Template:
Plan
Permit Number
10179304
Full Address
1408 W Second St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REQUIRED SIGNAGE <br />1. LABEL FOR JUNCTION BOX: 690.35(F) <br />WARNING! <br />ELECTRIC SHOCK HAZARD <br />IF A GROUND FAULT IS INDICATED, NORMALLY <br />GROUNDED CONDUCTORS MAY BE UNGROUNDED <br />AND ENERGIZED <br />2. LABEL FOR SOLAR AC DISCONNECT: 690.53 <br />OPERATING CURRENT: 12.6 A <br />OPERATING VOLTAGE: 240 VAC <br />MAXIMUM OUTPUT POWER: 3.0 kW <br />7. ON ALL INVERTER AND EXTERIOR PV CONDUIT, <br />RACEWAYS, ENCLOSURES, CABLE ASSEMBLIES AND <br />JUNCTION BOXES PROVIDE A SIGN WITH THE FOLLOWING <br />WORDING: <br />CAUTION <br />SOLAR CIRCUIT <br />MARKING SHALL BE PLACED EVERY 10 FEET AT TURNS <br />AND ABOVE AND/ OR BELOW PENETRATIONS AND AT <br />ALL PV COMBINER AND JUNCTION BOXES. <br />AC CONDUCTOR AMPACITY CALC'S <br />(FROM AC DISCONNECT TO MAIN SERVICE PANEL) <br /># OF INVERTER: 14 <br />EXPECTED WIRE TEMP. (°C): 31 <br />TEMP. CORR. PER NEC TABLE 310.16: 0.96 <br />CIRCUIT CONDUCTOR SIZE: AWG 10 THWN-2 <br /># OF CURRENT CARRYING CONDUCTORS: 3 <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a): 1 <br />CIRCUIT CONDUCTOR AMPACITY: 40A <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY <br />PER NEC TABLE 690.8(B): <br />1.25 x MAX INVERTER OUTPUT CURRENT X # OF INVERTER <br />1.25 x 0.9 x14 =15.8A <br />DERATED AMPACITY OF CIRCUIT CONDUCTORS PER <br />3. PROVIDE A PLACARD WITH THE FOLLOWING <br />WORDING IN 1/4" HIGH LETTERING <br />LABEL FOR SOLAR AC DISCONNECT: 690.17(4) <br />WARNING! <br />ELECTRICAL SHOCK HAZARD <br />DO NOT TOUCH TERMINALS. TERMINALS ON BOTH <br />THE LINE AND LOAD SIDES MAY BE ENERGIZED IN <br />THE OPEN POSITION <br />4. LABEL FOR SOLAR AC DISCONNECT: 690.14(C)(2) <br />SOLAR AC DISCONNECT <br />5. LABEL FOR INSIDE MAIN SERVICE PANEL: 690.64(B)(7) <br />WARNING! <br />INVERTER OUTPUT CONNECTION <br />DO NOT RELOCATE THIS OVERCURRENT DEVICE <br />FIRE DEPARTMENT REQUIRED SIGNAGE <br />ELECTRICAL CALCULATIONS <br />OPERATION VOLTAGE= 240 V <br />OPERATING CURRENT= 14 X 0.9= 12.6 A <br />MAX PV VOLTAGE & CURRENT CALC'S <br />MAXIMUM AC OUTPUT POWER: 4 <br />215 x 14 = 3.0 kW <br />MAXIMUM PV SYSTEM DC VOLTAGE <br />PER NEC 690.7 <br />37.14 x 1.12 = 41.6 V <br />MAXIMUM PV CONTINUOUS DC CURRENT <br />PER NEC 690.8(A)(1) <br />1.25 x 8.45 xl= 10.6A <br />AC CONDUCTOR AMPACITY CALC'S <br />(FROM STRING TO AC DISCONNECT) <br /># OF INVERTER: 14 <br />EXPECTED WIRE TEMP. (°C): 53 <br />TEMP. CORR. PER NEC TABLE 310.16: 0.76 <br />CIRCUIT CONDUCTOR SIZE: AWG 10 THWN-2 .. <br /># OF CURRENT CARRYING CONDUCTORS: 3 <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a): 1.0 <br />CIRCUIT CONDUCTOR AMPACITY: 40A <br />NEC TABLE 310.16: <br />TEMP. CORR. PER NEC TABLE 310.16 x <br />- CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) x <br />CIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.16 <br />0.96-x 1 x 40 = 38.4A > 15.8A O.K. <br />20A PV BREAKER WILL BE PROVIDED <br />BACKFED 120% RULE PER NEC 690 <br />120% x BUS RATING>=MAIN BREAKER + PV BREAKER <br />120% x 100A>=100A+PV BREAKER <br />' PV BREAKER <= 20A <br />20A<= 20A O.K. <br />% <br />1 g <br />DRAWN BY: <br />6. THE FOLLOWING SIGNAGE MUST HAVE A MINIMUM <br />OF 3/8" HIGH LETTERING, IN ARIAL FONT(NON-BOLD), <br />WITH CAPITAL LETTERS, WHITE ON RED BACKGROUND <br />AND ON A REFLECTIVE, WEATHER RESISTANT MATERIAL. <br />AT THE MAIN SERVICE DISCONNECT PROVIDE A SIGN <br />WITH THE FOLLOWING WORDING: <br />- CAUTION <br />SOLAR ELECTRIC SYSTEM CONNECTED <br />THE SIGN SHOULD BE PLACED ON THE OUTSIDE COVER <br />IF THE MAIN SERVICE DISCONNECT IS OPERABLE WITH <br />THE SERVICE PANEL CLOSED <br />REQUIRED CIRCUIT CONDUCTOR AMPACITY 90 @*<ts <br />o t=ei2PER NEC TABLE 690.8(B):i @ 4% 16 6 <br />1.25 x MAX INVERTER OUTPUT CURRENT X # OF INVERTER <br />1.25 x 0.9 x 14 =15.8A TITLE: <br />DERATED AMPACITY OF CIRCUIT CONDUCTORS CALCULATI0N <br />SIGNAGEPER NEC TABLE 310.16: <br />TEMP. CORR. PER NEC TABLE 310.16 x --- <br />CONDUIT FILL CORR. PER NEC 310.15(B)(2)(a) x <br />JOB NO: 20492XCIRCUIT CONDUCTOR AMPACITY PER NEC TABLE 310.16 <br />0.76 x 1.0 x 40 = 30.4A > 15.8A O.K.DATE: 07/03/13 <br />10 AWG WIRE IS O.K. <br />PV 4
The URL can be used to link to this page
Your browser does not support the video tag.